Diagnostic Accuracy of Contrast-Enhanced Ultrasound (CEUS) in the Detection of Muscle-Invasive Bladder Cancer: A Systematic Review and Diagnostic Meta-Analysis

被引:8
|
作者
Tufano, Antonio [1 ]
Rosati, Davide [1 ]
Moriconi, Martina [1 ]
Santarelli, Valerio [1 ]
Canale, Vittorio [1 ]
Salciccia, Stefano [1 ]
Sciarra, Alessandro [1 ]
Franco, Giorgio [1 ]
Cantisani, Vito [2 ]
Di Pierro, Giovanni Battista [1 ]
机构
[1] Sapienza Rome Univ, Policlin Umberto Hosp 1, Dept Maternal Infant & Urol Sci, I-00185 Rome, Italy
[2] Univ Roma La Sapienza, Dept Radiol Oncol & Pathol, I-00185 Rome, Italy
关键词
contrast-enhanced ultrasound (CEUS); bladder cancer; accuracy; muscle invasive; ultrasound; meta-analysis; GUIDELINES;
D O I
10.3390/curroncol31020060
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Contrast-enhanced ultrasound (CEUS) is a diagnostic tool that is gaining popularity for its ability to improve overall diagnostic accuracy in bladder cancer (BC) staging. Our aim is to determine the cumulative diagnostic performance of CEUS in predicting preoperative muscle invasiveness using a comprehensive systematic review and pooled meta-analysis. Methods: A systematic review until October 2023 was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Patients with BC suspicion were offered CEUS before the transurethral resection of the bladder tumor (TURBT). The diagnostic performance of CEUS was evaluated based on non-muscle-invasive bladder cancer (NMIBC) vs. muscle-invasive bladder cancer (MIBC) confirmed at the final histopathological examination after TURBT. The outcomes were determined through pooled sensitivity, specificity, pooled positive likelihood ratio (PLR+), negative likelihood ratio (PLR-), and area under the summary receiver operating characteristic (SROC) along with their respective 95% confidence intervals (CI). Results: Overall, five studies were included. In these studies, a total of 362 patients underwent CEUS prior to TURBT. The pooled sensitivity and specificity were 0.88 (95% CI: 0.81-0.93) and 0.88 (95% CI: 0.82-0.92), respectively. SROC curve depicted a diagnostic accuracy of 0.94 (95% CI: 0.81-0.98). The pooled PLR+ and PLR- were 7.3 (95% CI: 4.8-11.2) and 0.14 (95% CI: 0.08-0.23), respectively. Conclusions: Our meta-analysis indicates that CEUS is highly accurate in the diagnosis and staging for BC. Beyond its accuracy, CEUS offers the advantage of being a cost-effective, safe, and versatile imaging tool.
引用
收藏
页码:818 / 827
页数:10
相关论文
共 50 条
  • [1] Diagnostic Performance of Contrast-Enhanced Ultrasound (CEUS) and Contrast-Enhanced Endoscopic Ultrasound (ECEUS) for the Differentiation of Pancreatic Lesions: A Systematic Review and Meta-Analysis
    D'Onofrio, M.
    Biagioli, E.
    Gerardi, C.
    Canestrini, S.
    Rulli, E.
    Crosara, S.
    De Robertis, R.
    Floriani, I.
    ULTRASCHALL IN DER MEDIZIN, 2014, 35 (06): : 515 - 521
  • [2] Diagnostic accuracy of contrast-enhanced ultrasound in the detection of small renal masses A protocol of systematic review and meta-analysis
    Wu, Jiang-feng
    Wu, Chao
    Wang, Yun-lai
    Wang, Zheng-ping
    MEDICINE, 2020, 99 (29) : E21262
  • [3] Diagnostic Accuracy of Contrast-Enhanced MRI for Detection of Perineural Spread in Head and Neck Cancer: A Systematic Review and Meta-Analysis
    Sharma, Pranav
    Ajjikuttira, Aiyapa
    Malacova, Eva
    Gillespie, Jennifer
    JOURNAL OF NEUROLOGICAL SURGERY PART B-SKULL BASE, 2024, 85 : e97 - e109
  • [4] Diagnostic performance of contrast-enhanced ultrasound for pancreatic neoplasms: A systematic review and meta-analysis
    Li, Xing-Zhao
    Song, Jun
    Sun, Zhi-Xia
    Yang, Yan-Yan
    Wang, Hui
    DIGESTIVE AND LIVER DISEASE, 2018, 50 (02) : 132 - 138
  • [5] Diagnostic accuracy of contrast-enhanced ultrasound for microvascular invasion of hepatocellular carcinoma A protocol for systematic review and meta-analysis
    Chen, Yanli
    Qiao, Haiyan
    Lian, Zhaoan
    Li, Chunlin
    Xiang, Yi
    MEDICINE, 2022, 101 (15) : E29083
  • [6] Diagnostic accuracy of contrast-enhanced ultrasound to differentiate benign and malignant breast lesions: A systematic review and meta-analysis
    Wang, Jing
    Zhao, Rui
    Cheng, Jia
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 149
  • [7] Diagnostic accuracy of contrast-enhanced ultrasound for renal cell carcinoma: a meta-analysis
    Wang, Cong
    Yu, Chong
    Yang, Fang
    Yang, Guang
    TUMOR BIOLOGY, 2014, 35 (07) : 6343 - 6350
  • [8] Diagnostic Performance of Contrast-Enhanced Ultrasound in Renal Cancer: A Meta-Analysis
    Pan, Ke-Hao
    Jian, Li
    Chen, Wei-Jun
    Nikzad, Abdul Aziz
    Kong, Fang Q.
    Bin, Xu
    Wang, Ya-Li
    Chen, Ming
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [9] Diagnostic value of contrast-enhanced ultrasound in ovarian cancer: a meta-analysis
    Li, Jing
    Kong, Wei-min
    ACTA RADIOLOGICA, 2025, 66 (05) : 461 - 469
  • [10] DIAGNOSTIC PERFORMANCE OF CONTRAST-ENHANCED ULTRASOUND FOR OVARIAN CANCER: A META-ANALYSIS
    Wu, Ying
    Peng, Hongling
    Zhao, Xia
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (04): : 967 - 974