3D printed imaging apertures for MicroPattern gas detector based full field of view X-ray fluorescence spectrometers

被引:0
|
作者
Carvalho, P. M. S. [1 ]
Leite, F. D. [1 ]
Tavares, Gil [1 ]
Correia, P. M. M. [1 ]
Oliveira, J. M. M. [2 ,3 ]
Veloso, J. F. C. A. [1 ]
Silva, A. L. M. [1 ]
机构
[1] Univ Aveiro, Dept Phys, Inst Nanostruct Nanomodelling & Nanofabricat I3N, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[2] Univ Aveiro, Aveiro Inst Mat, CICECO, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[3] Univ Aveiro, Escola Super Design Gestao & Tecnol Prod Aveiro No, Estr Cercal 449, P-3720509 Santiago de Riba Ul, Oliveira de Aze, Portugal
关键词
Full-field XRF imaging; 3D printing; Multi-hole collimator; Sensitivity; Position resolution; FABRICATION; COLLIMATORS; SPECT;
D O I
10.1016/j.sab.2023.106806
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Additive Manufacturing, commonly referred as 3D printing, opened a new way to promptly produce cost-effective imaging apertures based on high-density materials, to be used in x-ray imaging systems, such as MicroPattern Gas Detector (MPGD) based Full Field X-ray Fluorescence (FF-XRF) spectrometers. These provide energy and spatially resolved information, allowing the mapping of large area samples. Traditionally, image formation is accomplished with pinhole apertures, devices of easy manufacturing that lead to sub-micrometre position resolution values. However, the sensitivity of the imaging system is severely hampered. To surpass this issue, alternative optical components, such as parallel multi-hole collimators, can be used.In this work, 3D printed multi-hole collimators with different geometries and material compositions are presented and applied to a FF-XRF spectrometer based on the 2D-THCOBRA gas detector. The system's performance parameters with different collimators, namely, relative sensitivity and position resolution, were experimentally determined and compared with the ones obtained with pinhole-based setups. The FF-XRF spectrometer was also simulated, to understand how different collimator geometries affect sensitivity and position resolution.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Energy resolved X-ray fluorescence imaging based on a micropattern gas detector
    Veloso, J. F. C. A.
    Silva, A. L. M.
    Oliveira, C. A. B.
    Gouvea, A. L.
    Azevedo, C. D. R.
    Carramate, L.
    da Luz, H. Natal
    dos Santos, J. M. F.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (03) : 241 - 247
  • [2] On the way to full-field X-ray fluorescence spectroscopy imaging with coded apertures
    Kulow, Anico
    Buzanich, Ana Guilherme
    Reinholz, Uwe
    Streli, Christina
    Radtke, Martin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (02) : 347 - 356
  • [3] Characterization of an energy dispersive X-ray fluorescence imaging system based on a Micropattern Gaseous Detector
    Silva, A. L. M.
    Azevedo, C. D. R.
    Oliveira, C. A. B.
    Dos Santos, J. M. F.
    Carvalho, M. L.
    Veloso, J. F. C. A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (05) : 308 - 313
  • [4] A photoelectric polarimeter based on a micropattern gas detector for X-ray astronomy
    Bellazzini, R
    Baldini, L
    Brez, A
    Costa, E
    Latronico, L
    Omodei, N
    Soffitta, P
    Spandre, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 510 (1-2): : 176 - 184
  • [5] Spherical Crystal Based on X-Ray Fluorescence Imaging with High Spectral Resolution and Full Field of View
    Tan Bozhong
    Yang Qingguo
    Du Liangliang
    An Ran
    Liu Dongbing
    Meng Limin
    ACTA OPTICA SINICA, 2019, 39 (11)
  • [6] Retrieval of 3D information in X-ray dark-field imaging with a large field of view
    Jana Andrejewski
    Fabio De Marco
    Konstantin Willer
    Wolfgang Noichl
    Theresa Urban
    Manuela Frank
    Alex Gustschin
    Pascal Meyer
    Thomas Koehler
    Franz Pfeiffer
    Julia Herzen
    Scientific Reports, 11
  • [7] Retrieval of 3D information in X-ray dark-field imaging with a large field of view
    Andrejewski, Jana
    De Marco, Fabio
    Willer, Konstantin
    Noichl, Wolfgang
    Urban, Theresa
    Frank, Manuela
    Gustschin, Alex
    Meyer, Pascal
    Koehler, Thomas
    Pfeiffer, Franz
    Herzen, Julia
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [8] X-ray color imaging with 3D sensitive voxel detector
    Soukup, P.
    Jakubek, J.
    Jandejsek, I.
    Zemlicka, J.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [9] 3D-printed coded apertures for x-ray backscatter radiography
    Munoz, Andre A. M.
    Vella, Anna
    Healy, Matthew J. F.
    Lane, David W.
    Jupp, Ian
    Lockley, David
    RADIATION DETECTORS IN MEDICINE, INDUSTRY, AND NATIONAL SECURITY XVIII, 2017, 10393
  • [10] Full-field X-ray fluorescence imaging with a straight polycapillary X-ray collimator
    An, S.
    Krapohl, D.
    Norlin, B.
    Thungstrom, G.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (12)