Interpretable Machine Learning Model to Predict Bone Cement Leakage in Percutaneous Vertebral Augmentation for Osteoporotic Vertebral Compression Fracture Based on SHapley Additive exPlanations

被引:3
|
作者
Hu, Yi-Li [1 ]
Wang, Pei-Yang [1 ]
Xie, Zhi-Yang [1 ]
Ren, Guan-Rui [1 ]
Zhang, Cong [1 ]
Ji, Hang-Yu [1 ]
Xie, Xin-Hui [1 ]
Zhuang, Su-Yang [1 ]
Wu, Xiao-Tao [1 ,2 ]
机构
[1] Southeast Univ, ZhongDa Hosp, Sch Med, Dept Spine Surg, Nanjing, Peoples R China
[2] Southeast Univ, ZhongDa Hosp, Sch Med, Dept Spine Surg, Nanjing 210009, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
bone cement leakage; osteoporotic vertebral compression fracture; percutaneous vertebral augmentation; machine learning; interpretable model; SHapley Additive exPlanations values; RISK-FACTORS; INTRAVERTEBRAL CLEFT; VERTEBROPLASTY; KYPHOPLASTY; METAANALYSIS;
D O I
10.1177/21925682231204159
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: Retrospective study. Objectives: Our objective is to create comprehensible machine learning (ML) models that can forecast bone cement leakage in percutaneous vertebral augmentation (PVA) for individuals with osteoporotic vertebral compression fracture (OVCF) while also identifying the associated risk factors. Methods: We incorporated data from patients (n = 425) which underwent PVA. To predict cement leakage, we devised six models based on a variety of parameters. Evaluate and juxtapose the predictive performances relied on measures of discrimination, calibration, and clinical utility. SHapley Additive exPlanations (SHAP) methodology was used to interpret model and evaluate the risk factors associated with cement leakage. Results: The occurrence rate of cement leakage was established at 50.4%. A binary logistic regression analysis identified cortical disruption (OR 6.880, 95% CI 4.209-11.246), the basivertebral foramen sign (OR 2.142, 95% CI 1.303-3.521), the fracture type (OR 1.683, 95% CI 1.083-2.617), and the volume of bone cement (OR 1.198, 95% CI 1.070-1.341) as independent predictors of cement leakage. The XGBoost model outperformed all others in predicting cement leakage in the testing set, with AUC of .8819, accuracy of .8025, recall score of .7872, F1 score of .8315, and a precision score of .881. Several important factors related to cement leakage were drawn based on the analysis of SHAP values and their clinical significance. Conclusion: The ML based predictive model demonstrated significant accuracy in forecasting bone cement leakage for patients with OVCF undergoing PVA. When combined with SHAP, ML facilitated a personalized prediction and offered a visual interpretation of feature importance.
引用
收藏
页码:689 / 701
页数:13
相关论文
共 50 条
  • [1] Cement Leakage in Percutaneous Vertebral Augmentation for Osteoporotic Vertebral Compression Fractures Analysis of Risk Factors
    Xie, Weixing
    Jin, Daxiang
    Ma, Hui
    Ding, Jinyong
    Xu, Jixi
    Zhang, Shuncong
    Liang, De
    CLINICAL SPINE SURGERY, 2016, 29 (04): : E171 - E176
  • [2] Risk factors for bone cement displacement after percutaneous vertebral augmentation for osteoporotic vertebral compression fractures
    Gao, Xiangcheng
    Du, Jinpeng
    Gao, Lin
    Hao, Dingjun
    Hui, Hua
    He, Baorong
    Yan, Liang
    FRONTIERS IN SURGERY, 2022, 9
  • [3] Precooling storage of bone cement in percutaneous vertebroplasty for osteoporotic vertebral compression fracture
    Xiao, Shan-Wen
    Zhou, Su-Fang
    Pan, Shi-Xin
    Li, Guo-Dong
    Li, Quan
    Li, Ai-Hui
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [4] Risk factors for cement leakage after percutaneous vertebral augmentation for osteoporotic vertebral compression fractures: a meta-analysis
    Wu, Yu
    Zhou, Zelin
    Lu, Guoliang
    Ye, Linqiang
    Lao, Aotian
    Ouyang, Shuai
    Song, Zefeng
    Zhang, Zhigang
    INTERNATIONAL JOURNAL OF SURGERY, 2025, 111 (01) : 1231 - 1243
  • [5] Treatment of multiple osteoporotic vertebral compression fractures by percutaneous cement augmentation
    Saracen, Agnieszka
    Kotwica, Zbigniew
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (11) : 2309 - 2312
  • [6] Treatment of multiple osteoporotic vertebral compression fractures by percutaneous cement augmentation
    Agnieszka Saracen
    Zbigniew Kotwica
    International Orthopaedics, 2014, 38 : 2309 - 2312
  • [7] Risk factors of postoperative bone cement leakage on osteoporotic vertebral compression fracture: a retrospective study
    Kui Zhang
    Jiang She
    Yandong Zhu
    Wenji Wang
    Erliang Li
    Ding Ma
    Journal of Orthopaedic Surgery and Research, 16
  • [8] Risk factors of postoperative bone cement leakage on osteoporotic vertebral compression fracture: a retrospective study
    Zhang, Kui
    She, Jiang
    Zhu, Yandong
    Wang, Wenji
    Li, Erliang
    Ma, Ding
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [9] The effect of bone cement on the curative effect of percutaneous kyphoplasty in the treatment of osteoporotic vertebral compression fracture
    Lu, Quanyi
    Gao, Shichang
    Zhou, Mingke
    ANNALS OF PALLIATIVE MEDICINE, 2021, 10 (10) : 11013 - 11023
  • [10] Adjacent vertebral fractures after percutaneous vertebral augmentation of osteoporotic vertebral compression fracture: a comparison of balloon kyphoplasty and vertebroplasty
    I. Movrin
    R. Vengust
    R. Komadina
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 1157 - 1166