Sensitive analysis of selenium speciation in natural seawater by isotope-dilution and large volume injection using PTV-GC-ICP-MS

被引:2
|
作者
Breuninger, Esther S. [1 ,2 ]
Tolu, Julie [1 ,2 ]
Bouchet, Sylvain [1 ,2 ]
Winkel, Lenny H. E. [1 ,2 ]
机构
[1] Swiss Fed Inst Technol Zurich ETHZ, Inst Biogeochem & Pollutant Dynam IBP, Univ str 16, CH-8092 Zurich, Switzerland
[2] Swiss Fed Inst Aquat Sci & Technol Eawag, Dept Water Resources & Drinking Water, Ueberlandstr 133, CH-8600 Dubendorf, Switzerland
基金
瑞士国家科学基金会;
关键词
Selenium speciation; Aquatic ecosystems; Derivatization; Isotope dilution; Gas chromatography; Mass spectrometry; CAPILLARY GAS-CHROMATOGRAPHY; DISSOLVED INORGANIC SELENIUM; SINGLE REACTION CHAMBER; ASSISTED WET DIGESTION; HYDRIDE GENERATION; WATER SAMPLES; ELEMENTAL DETERMINATION; PIAZSELENOL FORMATION; ATLANTIC-OCEAN; SEA-WATER;
D O I
10.1016/j.aca.2023.341833
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Although oceans play a key role in the global selenium (Se) cycle, there is currently very little quantitative information available on the distribution of Se concentrations and Se speciation in marine environments. In general, determining Se concentration and speciation in seawater is highly challenging due to very low Se levels ((sub)ng center dot L-1), whereas matrix elements interfering Se pre-concentration and detection are up to the g center dot L-1 levels. In this study, we established a sensitive method for the determination of the various Se chemical fractions present in natural seawater, i.e. selenite (SeIV), selenate (SeVI), organic Se-II + Se0 and total Se, using species-specific isotope dilution gas chromatography coupled to inductively coupled plasma mass spectrometry (ID-GC-ICPMS). We compared different derivatization reagents and optimized specific pre-treatment protocols, including a microwave assisted oxidation protocol for the determination of total Se and organic Se-II + Se0 using H2O2. To increase sensitivity, we developed an online pre-concentration method based on large volume injection (LVI) using a programmed temperature vaporization (PTV) inlet. Eventually, the developed method achieved low absolute and methodological detection limits, i.e., respectively, 0.1-0.3 pg and 0.9-3.1 ng.L-1 for the different fractions. The accuracy of our method was of 2% for a certified reference material (CRM) diluted in artificial seawater while the precision was better than 4% for a freshwater CRM in artificial seawater matrix as well as two common seawater CRMs certified for trace elements excluding Se. As a proof-of-concept, we quantified the various Se fractions in a large number of natural water samples from the Baltic and North Seas, encompassing a wide range of salinity (7-35 psu), which shows that its detection limits are sufficient to determine total Se, SeIV, SeVI and organic Se-II + Se0 concentrations in brackish and marine systems.
引用
收藏
页数:10
相关论文
共 40 条
  • [1] Mercury speciation analysis in human hair by species-specific isotope-dilution using GC–ICP–MS
    Laure Laffont
    Laurence Maurice
    David Amouroux
    Patricia Navarro
    Mathilde Monperrus
    Jeroen E. Sonke
    Philippe Behra
    Analytical and Bioanalytical Chemistry, 2013, 405 : 3001 - 3010
  • [2] Mercury speciation analysis in human hair by species-specific isotope-dilution using GC-ICP-MS
    Laffont, Laure
    Maurice, Laurence
    Amouroux, David
    Navarro, Patricia
    Monperrus, Mathilde
    Sonke, Jeroen E.
    Behra, Philippe
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (09) : 3001 - 3010
  • [3] Determination of plutonium isotopes in seawater reference materials using isotope-dilution ICP-MS
    Zheng, Jian
    Yamada, Masatoshi
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 1944 - 1948
  • [4] Total determination and quantitative speciation analysis of selenium in yeast and wheat flour by isotope dilution analysis ICP-MS
    Huerta, VD
    Reyes, LH
    Marchante-Gayón, JM
    Sánchez, MLF
    Sanz-Medel, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (10) : 1243 - 1247
  • [5] Total determination and quantitative speciation analysis of selenium in yeast and wheat flour by isotope dilution analysis ICP-MS
    Díaz Huerta, Vanesa
    Hinojosa Reyes, Laura
    Marchante-Gayón, Juan Manuel
    Fernández Sánchez, María Luisa
    Sanz-Medel, Alfredo
    Sanz-Medel, A. (asm@correo.uniovi.es), 1600, Royal Society of Chemistry (18):
  • [6] Accurate analysis of selenium in water and serum using ETV-ICP-MS with isotope dilution
    Turner, J
    Hill, SJ
    Evans, EH
    Fairman, B
    Briche, CSJW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (06) : 743 - 746
  • [7] Advanced GC/ICP-MS design for high-boiling analyte speciation and large volume solvent injection
    Glindemann, D
    Ilgen, G
    Herrmann, R
    Gollan, T
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) : 1386 - 1389
  • [8] Automated on-line isotope dilution analysis with ICP-MS using sandwich flow injection
    Specht, AA
    Beauchemin, D
    ANALYTICAL CHEMISTRY, 1998, 70 (05) : 1036 - 1040
  • [10] A DOUBLE ISOTOPE-DILUTION METHOD FOR USING STABLE SELENIUM ISOTOPES IN METABOLIC TRACER STUDIES - ANALYSIS BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY (GC/MS)
    REAMER, DC
    VEILLON, C
    JOURNAL OF NUTRITION, 1983, 113 (04): : 786 - 792