Post-earthquake functionality assessment for urban subway systems: Incorporating the combined effects of seismic performance of structural and non-structural systems and functional interdependencies

被引:10
|
作者
Hu, Jie [1 ,2 ]
Wen, Weiping [1 ,2 ,3 ]
Zhai, Changhai [1 ,2 ,3 ]
Pei, Shunshun [1 ,2 ]
机构
[1] Harbin Inst Technol, Key Lab Struct Dynam Behav & Control, Minist Educ, Harbin 150090, Peoples R China
[2] Harbin Inst Technol, Minist Ind & Informat Technol, Key Lab Smart Prevent Mitigat Civil Engn Disaster, Harbin 150090, Peoples R China
[3] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Peoples R China
基金
中国国家自然科学基金;
关键词
Subway system; Urban rail transit; Interdependency; Post-earthquake functionality; Resilience; RAIL TRANSIT NETWORKS; DEMAND MODELS; PROBABILISTIC CAPACITY; RESILIENCE; ROBUSTNESS; FAILURE; METRO; VULNERABILITY; SHANGHAI; SPEED;
D O I
10.1016/j.ress.2023.109641
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study proposes a framework to evaluate and quantify the post-earthquake functionality of subway systems. The effects of the seismic performance of structural and non-structural systems and the functional interdependencies at different levels are incorporated into the framework. Considering the characteristics of passenger flow and network topology of subway systems, global service efficiency is proposed as the functionality indicator. The computational efficiency of the proposed calculating algorithm of the functionality indicator is improved by 10 times compared to the conventional algorithm. The proposed framework is applied to an actual subway system as a numerical example to verify the effectiveness and operability of the proposed framework. The effects of the non-structural systems on the post-earthquake functionality assessment of the subway system are analyzed, and the result indicates that the post-earthquake functionality of the subway system would be overestimated owing to ignoring the effects of the non-structural systems, and the degree of overestimation is positively correlated with the earthquake intensity. The influence of the municipal power supply system as an essential external system is studied and the results show that the functionality of the subway system is highly dependent on the municipal power supply system.
引用
收藏
页数:18
相关论文
共 6 条
  • [1] Post-earthquake functionality assessment of subway stations considering the interdependency among sub-systems
    Wen, Weiping
    Hu, Jie
    Zhai, Changhai
    Pei, Shunshun
    COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, 2024, 39 (01) : 136 - 161
  • [2] A Systematic Review of Structural Health Monitoring Systems to Strengthen Post-Earthquake Assessment Procedures
    Lopez-Castro, Brian
    Gabriela Haro-Baez, Ana
    Arcos-Aviles, Diego
    Barreno-Riera, Marco
    Landazuri-Aviles, Bryan
    SENSORS, 2022, 22 (23)
  • [3] Seismic structural and non-structural performance evaluation of highly damped self-centering and conventional systems
    Karavasilis, Theodore L.
    Seo, Choung-Yeol
    ENGINEERING STRUCTURES, 2011, 33 (08) : 2248 - 2258
  • [4] A New Method to Evaluate the Post-Earthquake Performance and Safety of Reinforced Concrete Structural Frame Systems
    Konstandakopoulou, Foteini
    Hatzigeorgiou, George
    Evangelinos, Konstantinos
    Tsalis, Thomas
    Nikolaou, Ioannis
    INFRASTRUCTURES, 2020, 5 (02)
  • [5] Incorporation of BIM-based probabilistic non-structural damage assessment into agent-based post-earthquake evacuation simulation
    Hassanpour, Sajjad
    Gonzalez, Vicente A.
    Zou, Yang
    Liu, Jiamou
    Wang, Feng
    Castillo, Enrique del Rey
    Cabrera-Guerrero, Guillermo
    ADVANCED ENGINEERING INFORMATICS, 2023, 56
  • [6] Numerical hybrid simulation assessment of E-BRBF and E-FBF systems for mitigating P-delta effects and enhancing post-earthquake performance
    Hariri, Bashar
    Christopoulos, Constantin
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2024, 53 (12): : 3754 - 3774