Remote Sensing on Carbon Dioxide Emissions in Power Plants and Urban Areas Based on DOAS Technology

被引:1
|
作者
Zhang Huarong [1 ,2 ]
Xie Pinhua [1 ,2 ,3 ]
Xu Jin [1 ]
Lu Yinsheng [1 ,2 ]
Li Youtao [1 ]
Zhang Zhidong [1 ,2 ]
机构
[1] Chinese Acad Sci, Hefei Inst Phys Sci, Anhui Inst Opt & Fine Mech, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
spectroscopy; near; infrared differential optical absorption spectroscopy; optical remote sensing; CO2 concentration distribution; emission flux; OPTICAL-ABSORPTION SPECTROSCOPY; HETERODYNE RADIOMETER; QUANTIFICATION; METHANE; CH4; CO2; SPECTROMETER; PERFORMANCE; INSTRUMENT; SCIAMACHY;
D O I
10.3788/AOS230762
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Objective Carbon dioxide (CO2), methane (CH4), water vapor (H2O), and other greenhouse gases have the ability to absorb longwave radiation emitted by the earth to cause the greenhouse effect. The escalating greenhouse effect has resulted in a series of climate and environmental degradation issues. Accurate measurement of CO2 gas concentration and estimation of CO2 emission intensity from emission sources are of significance for controlling greenhouse gas emissions. Remote sensing methods based on passive differential optical absorption spectroscopy (DOAS) technology can measure the concentration of multiple gas components in real-time with high precision and can capture a wide range of gas concentration variations. Currently, researchers both domestically and internationally have made corresponding progress in measuring greenhouse gas concentrations and emission fluxes from emission sources using DOAS technology, mainly focusing on satellite and airborne platforms. However, there is relatively less research on emission flux estimation from typical emission sources using DOAS remote sensing methods on ground-based platforms. Focusing on typical emission sources and urban areas as the research targets, we employ a ground-based near-infrared spectroscopy remote sensing system coupled with differential absorption spectroscopy technology to retrieve the two-dimensional distribution of CO2 column concentration. Based on these results, the emission fluxes from typical emission sources are estimated to provide a reliable technique and method for remote sensing of carbon emissions. Methods The near-infrared DOAS algorithm for retrieving CO2 concentration information is first studied, and the spectral range and interfering gases for CO2 inversion are selected by analyzing the distribution of gas absorption line intensity in the HITRAN database. Meanwhile, we calculate the effective absorption cross-sections of the gases in the measurement environment through line broadening and convolution. The absorption cross-sections of CH4 and H2O are included in the retrieval to account for their interference in the absorption spectra. The influence of reference spectrum selection on the retrieval results is analyzed, and ultimately the zenith direction spectrum is chosen as the reference spectrum. The CO2 column concentration information is obtained using least-squares fitting. By subtracting the gas concentration in the first column upwind from the obtained CO2 column concentration and considering the angular information of the remote sensing system, the two-dimensional concentration distribution of CO2 columns in the vicinity of the power plant and the boundary layer of Hefei is obtained. The bicubic interpolation algorithm is applied to achieve high spatial resolution for the two-dimensional distribution of CO2 column concentrations. Furthermore, the CO2 emission flux from the power plant is calculated, and the error sources are analyzed. Results and Discussions We choose the background spectrum as the reference spectrum, and employ the DOAS algorithm to retrieve CO2 column density. The retrieval error can reach 0. 79%. The remote sensing results of a chimney in a power plant in Hefei show that high concentrations of CO2 are concentrated above the chimney outlet, and the slant column density of CO2 at the emission hotspot is approximately 3. 36x1021 molecule/cm(2) higher than the background concentration (Fig. 9). The high concentrations of CO2 emitted from the power plant are mainly distributed within a height range of 35 m above the chimney outlet (Fig. 10). By utilizing the bicubic interpolation algorithm, the spatial resolution of the power plant's CO2 concentration distribution map is improved from 5 mx5 m to 1. 25 mx1. 25 m (Fig. 11). The emission flux from the power plant is about 1925 kg and the distance estimation error is the largest error source in the flux measurement. The remote sensing results in the boundary layer of Hefei indicate that both the power plant and the urban area have higher concentrations compared to the suburban area. After subtracting the complex background, the highest concentration in the urban area reaches up to 2. 58x1021 molecule/cm(2). The thickness of the high-concentration layer in the power plant is approximately 279. 2 m, while it is 418. 8 m in the urban area (Fig. 13). Conclusions We introduce a near-infrared spectroscopy remote sensing system and estimation method for measuring CO2 column density distribution and emission fluxes, and investigate the distribution characteristics of CO2 from typical point sources and urban emissions. A power plant is selected as a point source for emission research. Scanning measurements are conducted in the vertical direction of the power plant plume dispersion to obtain a two-dimensional concentration distribution map of CO2 emissions from the power plant. The CO2 emission flux is calculated as about 1925 kg, and observations and research on the CO2 distribution characteristics in the atmospheric boundary layer of Hefei are also conducted. Preliminary results show that the high concentration values in the boundary layer are primarily distributed near the ground level, and the concentrations in the power plant and urban areas are significantly higher than those in the suburbs. This suggests that the fuel combustion in the power plant and emissions from transportation and manufacturing activities in urban areas play a major role in atmospheric CO2 concentration and distribution. Finally, we provide effective techniques and methods for estimating carbon emissions. The next step will involve adopting three-dimensional modeling to investigate the three-dimensional spatial distribution characteristics of the plume and combining precise wind speed measurement instruments for more accurate emission flux estimation.
引用
收藏
页数:10
相关论文
共 28 条
  • [1] Detection and quantification of CH4 plumes using the WFM-DOAS retrieval on AVIRIS-NG hyperspectral data
    Borchardt, Jakob
    Gerilowski, Konstantin
    Krautwurst, Sven
    Bovensmann, Heinrich
    Thorpe, Andrew K.
    Thompson, David R.
    Frankenberg, Christian
    Miller, Charles E.
    Duren, Riley M.
    Burrows, John Philip
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2021, 14 (02) : 1267 - 1291
  • [2] A near-infrared optimized DOAS method for the fast global retrieval of atmospheric CH4, CO, CO2, H2O, and N2O total column amounts from SCIAMACHY Envisat-1 nadir radiances
    Buchwitz, M
    Rozanov, VV
    Burrows, JP
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2000, 105 (D12) : 15231 - 15245
  • [3] SCIAMACHY - SCANNING IMAGING ABSORPTION SPECTROMETER FOR ATMOSPHERIC CHARTOGRAPHY
    BURROWS, JP
    HOLZLE, E
    GOEDE, APH
    VISSER, H
    FRICKE, W
    [J]. ACTA ASTRONAUTICA, 1995, 35 (07) : 445 - 451
  • [4] Development of a laser heterodyne spectroradiometer for high-resolution measurements of CO2, CH4, H2O and O2 in the atmospheric column
    Deng, Hao
    Yang, Chenguang
    Xu, Zhenyu
    Li, Mingxing
    Huang, An
    Yao, Lu
    Hu, Mai
    Chen, Bing
    He, Yabai
    Kan, Ruifeng
    Liu, Jianguo
    [J]. OPTICS EXPRESS, 2021, 29 (02) : 2003 - 2013
  • [5] Near infrared heterodyne radiometer for continuous measurements of atmospheric CO2 column concentration
    Deng, Hao
    Yang, Chenguang
    Wang, Wei
    Shan, Changgong
    Xu, Zhenyu
    Chen, Bing
    Yao, Lu
    Hu, Mai
    Kan, Ruifeng
    He, Yabai
    [J]. INFRARED PHYSICS & TECHNOLOGY, 2019, 101 : 39 - 44
  • [6] Design and Test of Dual-Channel Non-Dispersive Infrared CO2 Gas Sensor
    Dong Helei
    Liu Can
    Jin Changming
    Zhang Lei
    Zhang Yanan
    Tan Qiulin
    [J]. CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2023, 50 (02):
  • [7] Building the COllaborative Carbon Column Observing Network (COCCON): long-term stability and ensemble performance of the EM27/SUN Fourier transform spectrometer
    Frey, Matthias
    Sha, Mahesh K.
    Hase, Frank
    Kiel, Matthaus
    Blumenstock, Thomas
    Harig, Roland
    Surawicz, Gregor
    Deutscher, Nicholas M.
    Shiomi, Kei
    Franklin, Jonathan E.
    Bosch, Hartmut
    Chen, Jia
    Grutter, Michel
    Ohyama, Hirofumi
    Sun, Youwen
    Butz, Andre
    Tsidu, Gizaw Mengistu
    Ene, Dragos
    Wunch, Debra
    Cao, Zhensong
    Garcia, Omaira
    Ramonet, Michel
    Vogel, Felix
    Orphal, Johannes
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2019, 12 (03) : 1513 - 1530
  • [8] MAMAP - a new spectrometer system for column-averaged methane and carbon dioxide observations from aircraft: instrument description and performance analysis
    Gerilowski, K.
    Tretner, A.
    Krings, T.
    Buchwitz, M.
    Bertagnolio, P. P.
    Belemezov, F.
    Erzinger, J.
    Burrows, J. P.
    Bovensmann, H.
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2011, 4 (02) : 215 - 243
  • [9] The HITRAN2020 molecular spectroscopic database
    Gordon, I. E.
    Rothman, L. S.
    Hargreaves, R. J.
    Hashemi, R.
    Karlovets, E., V
    Skinner, F. M.
    Conway, E. K.
    Hill, C.
    Kochanov, R., V
    Tan, Y.
    Wcislo, P.
    Finenko, A. A.
    Nelson, K.
    Bernath, P. F.
    Birk, M.
    Boudon, V
    Campargue, A.
    Chance, K., V
    Coustenis, A.
    Drouin, B. J.
    Flaud, J-M
    Gamache, R. R.
    Hodges, J. T.
    Jacquemart, D.
    Mlawer, E. J.
    Nikitin, A., V
    Perevalov, V., I
    Rotger, M.
    Tennyson, J.
    Toon, G. C.
    Tran, H.
    Tyuterev, V. G.
    Adkins, E. M.
    Baker, A.
    Barbe, A.
    Cane, E.
    Csaszar, A. G.
    Dudaryonok, A.
    Egorov, O.
    Fleisher, A. J.
    Fleurbaey, H.
    Foltynowicz, A.
    Furtenbacher, T.
    Harrison, J. J.
    Hartmann, J-M
    Horneman, V-M
    Huang, X.
    Karman, T.
    Karns, J.
    Kassi, S.
    [J]. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2022, 277
  • [10] Nitrogen Oxides Spatial Distribution and Emissions with Mobile Multi-Axis Differential Optical Absorption Spectroscopy in Wuhan City
    Huang Yeyuan
    Li Ang
    Qin Min
    Hu Zhaokun
    Xie Pinhua
    Xu Jin
    Duan Jun
    Ren Hongmei
    Tian Xin
    Li Xiaomei
    Ren Bo
    Zhang Qiang
    Zhong Hongyan
    [J]. ACTA OPTICA SINICA, 2021, 41 (10)