Fiber SPR biosensor sensitized by MOFs for MUC1 protein detection

被引:19
|
作者
Wang, Rui [1 ]
Liu, Chunlan [1 ]
Wei, Yong [1 ]
Ran, Ze [1 ]
Jiang, Tianci [1 ]
Liu, Chunbiao [1 ]
Shi, Chen [1 ]
Ren, Zhuo [1 ]
Wang, Xingkai [1 ]
Liu, Zhihai [2 ]
Zhang, Yu [2 ]
机构
[1] Chongqing Three Gorges Univ, Coll Elect & Informat Engn, Chongqing 404100, Peoples R China
[2] Harbin Engn Univ, Key Lab Infiber Integrated Opt, Minist Educ China, Harbin 150001, Peoples R China
基金
中国国家自然科学基金;
关键词
Fiber SPR sensor; MUC1; MOFs; Aptamer; NANOCOMPOSITES; MUCIN1;
D O I
10.1016/j.talanta.2023.124467
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The concentration of tumor markers is low, which needs a highly sensitive, stable and fast detection method. In this paper, we proposed and demonstrated a U-shape fiber SPR biosensor sensitized by MOFs materials. The surface of the U-shape SPR sensor was modified with MOFs materials to enhance the sensitivity, and the nucleic acid aptamer was immobilized on the sensor surface because of the biocompatibility of MOFs materials. By the high specificity of the nucleic acid aptamer, the MUC1 protein was recognized and detected. The testing results indicate that the sensor has a logarithmic linear response in the MUC1 protein concentration detection range of 1 pg/ml-100 mu g/ml, its sensitivity and detection limit are 5.33 nm/log(mu g/ml) and 0.16 pg/ml respectively. After being sensitized by MOFs, the detection sensitivity of the sensor can be increased by 1.62 times,the LOD can be decreased by 0.75 times. The sensor has high sensitivity and specificity, which has broad application prospects in clinical detection of tumor markers.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Microsphere Sensitized Fiber Optic SPR Biosensor for Refractive Index Detection
    Sun, Huiying
    Zhu, Zhaocheng
    Wang, Fang
    Gong, Pengqi
    Zhou, Xue
    Li, Xuegang
    2024 13TH INTERNATIONAL CONFERENCE ON COMMUNICATIONS, CIRCUITS AND SYSTEMS, ICCCAS 2024, 2024, : 85 - 88
  • [2] Detection of a secreted MUC1/SEC protein by MUC1 isoform specific monoclonal antibodies
    Smorodinsky, N
    Weiss, M
    Hartmann, ML
    Baruch, A
    Harness, E
    Yaakobovitz, M
    Keydar, I
    Wreschner, DH
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1996, 228 (01) : 115 - 121
  • [3] A highly sensitive tapered fiber biosensor modified by PDMS combustion product and graphene oxide for MUC1 detection
    Wang, Bo
    Liu, Shanren
    Gao, Mengmeng
    Li, Yuanjun
    Yang, Heer
    Sun, Cai
    Guo, Qi
    Yu, Yongsen
    SENSORS AND ACTUATORS REPORTS, 2025, 9
  • [4] D-SPR optical fiber plasmonic biosensor for protein detection
    Thawany, Priyanka
    Tiwari, Umesh
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS, TREATMENT AND ENVIRONMENTAL APPLICATIONS XXII, 2022, 11953
  • [5] SPR Fiber Biosensor for Organic Molecules Detection
    Krepelka, Pavel
    INTERNATIONAL INTERDISCIPLINARY PHD WORKSHOP 2016, 2016, : 1 - 5
  • [6] Detection of circulating mammary mucin (MUC1) and MUC1 immune complexes (MUC1-CIC) in healthy women
    Croce, MV
    Isla-Larrain, MT
    Price, MR
    Segal-Eiras, A
    INTERNATIONAL JOURNAL OF BIOLOGICAL MARKERS, 2001, 16 (02): : 112 - 120
  • [7] Quantitative Detection of MUC1 Protein by Aptamer-Based Fluorescence Analysis
    Yang Y.-Z.
    Dai W.-Q.
    Lü X.-F.
    Deng Y.-L.
    Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology, 2019, 39 : 1 - 5
  • [8] THE IMMUNOGENICITY OF MUC1 PEPTIDES AND FUSION PROTEIN
    APOSTOLOPOULOS, V
    PIETERSZ, GA
    XING, PX
    LEES, CJ
    MICHAEL, M
    BISHOP, J
    MCKENZIE, IFC
    CANCER LETTERS, 1995, 90 (01) : 21 - 26
  • [9] The high luminescent polydopamine nanosphere-based ECL biosensor with steric effect for MUC1 detection
    Liang, Zihui
    Liu, Yang
    Zhang, Qian
    Guo, Yupeng
    Ma, Qiang
    CHEMICAL ENGINEERING JOURNAL, 2020, 385
  • [10] Development of Electrochemical Aptamer Biosensor for Tumor Marker MUC1 Determination
    Song, Jinhua
    Zhou, Yun
    Chen, Bech
    Lou, Wensheng
    Gu, Jianping
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (06): : 5618 - 5627