Characteristics and Functionality of Cantilevers and Scanners in Atomic Force Microscopy

被引:6
|
作者
Dzedzickis, Andrius [1 ]
Rozene, Juste [1 ]
Bucinskas, Vytautas [1 ]
Virzonis, Darius [1 ]
Morkvenaite-Vilkonciene, Inga [1 ]
机构
[1] Vilnius Gediminas Tech Univ, Dept Mechatron Robot & Digital Mfg, Plytines 25, LT-10105 Vilnius, Lithuania
关键词
atomic force microscope (AFM); cantilever; scanner; AFM PROBE; SPRING CONSTANTS; CONTACT MODE; SPEED; TIP; DESIGN; SPECTROSCOPY; FABRICATION; NONCONTACT; STIFFNESS;
D O I
10.3390/ma16196379
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this paper, we provide a systematic review of atomic force microscopy (AFM), a fast-developing technique that embraces scanners, controllers, and cantilevers. The main objectives of this review are to analyze the available technical solutions of AFM, including the limitations and problems. The main questions the review addresses are the problems of working in contact, noncontact, and tapping AFM modes. We do not include applications of AFM but rather the design of different parts and operation modes. Since the main part of AFM is the cantilever, we focused on its operation and design. Information from scientific articles published over the last 5 years is provided. Many articles in this period disclose minor amendments in the mechanical system but suggest innovative AFM control and imaging algorithms. Some of them are based on artificial intelligence. During operation, control of cantilever dynamic characteristics can be achieved by magnetic field, electrostatic, or aerodynamic forces.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Interdigital cantilevers for atomic force microscopy
    Manalis, SR
    Minne, SC
    Atalar, A
    Quate, CF
    APPLIED PHYSICS LETTERS, 1996, 69 (25) : 3944 - 3946
  • [2] Short cantilevers for atomic force microscopy
    Walters, DA
    Cleveland, JP
    Thomson, NH
    Hansma, PK
    Wendman, MA
    Gurley, G
    Elings, V
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (10): : 3583 - 3590
  • [3] Cantilevers and tips for atomic force microscopy
    Tortonese, M
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1997, 16 (02): : 28 - 33
  • [4] Millions of cantilevers for atomic force microscopy
    Kawakatsu, H
    Saya, D
    Kato, A
    Fukushima, K
    Toshiyoshi, H
    Fujita, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (03): : 1188 - 1192
  • [5] Millions of cantilevers for atomic force microscopy
    1600, American Institute of Physics Inc. (73):
  • [6] Atomic force microscopy and lateral force microscopy using piezoresistive cantilevers
    Linnemann, R
    Gotszalk, T
    Rangelow, IW
    Dumania, P
    Oesterschulze, E
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1996, 14 (02): : 856 - 860
  • [7] Atomic force microscopy and lateral force microscopy using piezoresistive cantilevers
    Linnemann, R.
    Gotszalk, T.
    Rangelow, I.W.
    Dumania, P.
    Oesterschulze, E.
    Journal of Vacuum Science & Technology B: Microelectronics Processing and Phenomena, 1996, 14 (02):
  • [8] Preamplifying cantilevers for dynamic atomic force microscopy
    Zeyen, Benedikt
    Virwani, Kumar
    Pittenger, Bede
    Turner, Kimberly L.
    APPLIED PHYSICS LETTERS, 2009, 94 (10)
  • [9] Carbon nanotube atomic force microscopy cantilevers
    Emirov, YN
    Schumacher, JD
    Lagel, B
    Nguyen, N
    Ren, ZF
    Huang, ZP
    Rossie, BB
    Schlaf, R
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XVIII, PTS 1 AND 2, 2004, 5375 : 1389 - 1392
  • [10] Advances in piezoresistive cantilevers for Atomic Force Microscopy
    Tortonese, M
    ATOMIC FORCE MICROSCOPY/SCANNING TUNNELING MICROSCOPY 2, 1997, : 147 - 153