Motion artifact removal in coronary CT angiography based on generative adversarial networks

被引:14
|
作者
Zhang, Lu [1 ]
Jiang, Beibei [1 ]
Chen, Qiang [2 ]
Wang, Lingyun [1 ]
Zhao, Keke [1 ]
Zhang, Yaping [1 ]
Vliegenthart, Rozemarijn [3 ]
Xie, Xueqian [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Radiol, Sch Med, Haining Rd 100, Shanghai 200080, Peoples R China
[2] Shukun Beijing Technol Co Ltd, Jinhui Bd,Qiyang Rd, Beijing 100102, Peoples R China
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Radiol, Hanzepl 1, NL-9700 RB Groningen, Netherlands
基金
中国国家自然科学基金;
关键词
Coronary CT angiography; Motion artifacts; Generative adversarial network;
D O I
10.1007/s00330-022-08971-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Coronary motion artifacts affect the diagnostic accuracy of coronary CT angiography (CCTA), especially in the mid right coronary artery (mRCA). The purpose is to correct CCTA motion artifacts of the mRCA using a GAN (generative adversarial network). Methods We included 313 patients with CCTA scans, who had paired motion-affected and motion-free reference images at different R-R interval phases in the same cardiac cycle and included another 53 CCTA cases with invasive coronary angiography (ICA) comparison. Pix2pix, an image-to-image conversion GAN, was trained by the motion-affected and motion-free reference pairs to generate motion-free images from the motion-affected images. Peak signal-to-noise ratio (PSNR), structural similarity (SSIM), Dice similarity coefficient (DSC), and Hausdorff distance (HD) were calculated to evaluate the image quality of GAN-generated images. Results At the image level, the median of PSNR, SSIM, DSC, and HD of GAN-generated images were 26.1 (interquartile: 24.4-27.5), 0.860 (0.830-0.882), 0.783 (0.714-0.825), and 4.47 (3.00-4.47), respectively, significantly better than the motion-affected images (p < 0.001). At the patient level, the image quality results were similar. GAN-generated images improved the motion artifact alleviation score (4 vs. 1, p < 0.001) and overall image quality score (4 vs. 1, p < 0.001) than those of the motion-affected images. In patients with ICA comparison, GAN-generated images achieved accuracy of 81%, 85%, and 70% in identifying no, < 50%, and >= 50% stenosis, respectively, higher than 66%, 72%, and 68% for the motion-affected images. Conclusion Generative adversarial network-generated CCTA images greatly improved the image quality and diagnostic accuracy compared to motion-affected images.
引用
收藏
页码:43 / 53
页数:11
相关论文
共 50 条
  • [1] Motion artifact removal in coronary CT angiography based on generative adversarial networks
    Lu Zhang
    Beibei Jiang
    Qiang Chen
    Lingyun Wang
    Keke Zhao
    Yaping Zhang
    Rozemarijn Vliegenthart
    Xueqian Xie
    European Radiology, 2023, 33 : 43 - 53
  • [2] Wasserstein generative adversarial networks for motion artifact removal in dental CT imaging
    Jiang, Changhui
    Zhang, Qiyang
    Ge, Yongshuai
    Liang, Dong
    Yang, Yongfeng
    Liu, Xin
    Zheng, Hairong
    Hu, Zhanli
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [3] Metal artifact correction of industrial CT images based on generative adversarial networks
    Jiang, Shibo
    Sun, Yuewen
    Xu, Shuo
    Wu, Zhifang
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2022, 43 (12): : 1766 - 1771
  • [4] Evaluation of motion artifact metrics for coronary CT angiography
    Ma, Hongfeng
    Gros, Eric
    Szabo, Aniko
    Baginski, Scott G.
    Laste, Zachary R.
    Kulkarni, Naveen M.
    Okerlund, Darin
    Schmidt, Taly G.
    MEDICAL PHYSICS, 2018, 45 (02) : 687 - 702
  • [5] Motion-Blind Blur Removal for CT Images with Wasserstein Generative Adversarial Networks
    Lyu, Yilin
    Jiang, Wei
    Lin, Yanjun
    Voros, Laszlo
    Zhang, Miao
    Mueller, Boris
    Mychalczak, Borys
    Song, Yulin
    2018 11TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2018), 2018,
  • [6] Motion artifact recognition and quantification in coronary CT angiography using convolutional neural networks
    Lossau, T.
    Nickisch, H.
    Wissel, T.
    Bippus, R.
    Schmitt, H.
    Morlock, M.
    Grass, M.
    MEDICAL IMAGE ANALYSIS, 2019, 52 : 68 - 79
  • [7] Generative Adversarial Networks for Coronary CT Angiography Acquisition Protocol Correction with Explicit Attenuation Constraints
    van Herten, Rudolf L. M.
    van Harten, Louis D.
    Planken, R. Nils
    Isgum', Ivana
    MEDICAL IMAGING WITH DEEP LEARNING, VOL 227, 2023, 227 : 1288 - 1303
  • [8] Generative adversarial network for coronary artery plaque synthesis in coronary CT angiography
    Zhai, Zhiwei
    Wang, Yining
    de Vos, Bob D.
    Noothout, Julia M. H.
    Planken, Nils
    Isgum, Ivana
    MEDICAL IMAGING 2022: IMAGE PROCESSING, 2022, 12032
  • [9] Deep Generative Adversarial Compression Artifact Removal
    Galteri, Leonardo
    Seidenari, Lorenzo
    Bertini, Marco
    Del Bimbo, Alberto
    2017 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV), 2017, : 4836 - 4845
  • [10] Cycle Consistent Generative Motion Artifact Correction in Coronary Computed Tomography Angiography
    Saleem, Amal Muhammad
    Jung, Sunghee
    Chang, Hyuk-Jae
    Lee, Soochahn
    APPLIED SCIENCES-BASEL, 2024, 14 (05):