Influence of luminance and luminance longitudinal uniformity of tunnel lighting on drivers' comprehensive visual performance

被引:9
|
作者
Kang, Cheng [1 ,2 ,3 ]
Lin, Guojun [4 ]
Ye, Lei [5 ]
Zhang, Chi [1 ]
Huang, Zhiyi [1 ]
Wu, Ke [1 ,2 ,6 ,7 ]
机构
[1] Zhejiang Univ, Key Lab Offshore Geotech & Mat Zhejiang Prov, Hangzhou 310058, Zhejiang, Peoples R China
[2] Zhejiang Univ, Ctr Balance Architecture, Hangzhou 310007, Zhejiang, Peoples R China
[3] Inst Grp Co Ltd, China Railway First Survey & Design, Xian 710043, Shaanxi, Peoples R China
[4] Ninghai Supervis Stn Traff Construct Engn Qual &, Ningbo 315600, Zhejiang, Peoples R China
[5] Zhejiang Prov Commun Dept, Construction Management Div, Hangzhou 310007, Zhejiang, Peoples R China
[6] Zhejiang Univ, Engn Res Ctr Ocean Sensing Technol & Equipment, Minist Educ, Hangzhou 310058, Zhejiang, Peoples R China
[7] West4 B220, Zijingang Campus, 866 yuhangtang Rd, Hangzhou, Zhejiang, Peoples R China
关键词
Traffic engineering; Luminance longitudinal uniformity; Indoor experiment; Comprehensive visual performance; Actual perceived luminance; Antagonism; CHOICE; IMPACT;
D O I
10.1016/j.tust.2023.105282
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The present study aimed to investigate the comprehensive influence of the average luminance Lav and luminance longitudinal uniformity U1 on the diver's visual performance under the stage of driving in the tunnel's interior zone during the experiment. Specifically, we collected reaction time, pupil area change rate, and blink frequency from 40 participants through the indoor visual performance experiments. The present study quantitatively characterized the mechanism of the antagonism between luminance intensity and difference, and established the Lav-U1 curve which succeeds in satisfying the safety threshold of the driver's comprehensive visual performance. The results show that the driver's visual performance deteriorated continuously as the test time increases. Increasing the luminance was beneficial for accelerating the reaction speed, but also caused greater stimulation of light and dark changes. The change ratio of reaction speed and the increased amplitude of perceived luminance increased exponentially with the increase of luminance, resulting in an antagonism effect. The visual performance decreased with the increase of average luminance under low uniformity levels, and increased with the increase of average luminance under high uniformity levels. Furthermore, we found that the luminance longitudinal uniformity should match up the luminance in the interior zone, instead of separation under the current specification. Based on our findings, we propose specific recommendations for the luminance longitudinal uniformity under different average luminance levels. For the interior zone of tunnels with an average luminance of 2.5, 4.5, and 6 cd/m2, the luminance longitudinal uniformity should be increased from 0.6 to 0.67, 0.72, and 0.75, respectively. Current findings demonstrate that the implementation of the proposed U1 standard in tunnel lighting design can significantly fasten drivers' reaction time, contribute to a decrease in traffic accidents, and thus improve the safety level of tunnel lighting design in the interior zone of tunnel. These results have significant implications for the design of tunnel lighting.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Preference for luminance uniformity of refrigerator lighting
    Jeong, Kyeong Ah
    You, Chanyang
    Suk, Hyeon-Jeong
    COLOR RESEARCH AND APPLICATION, 2021, 46 (01): : 146 - 154
  • [2] Energy savings in tunnel lighting by improving the road surface luminance uniformity - A new approach to tunnel lighting
    Kimura, Masayoshi
    Hirakawa, Satoshi
    Uchino, Hirohito
    Motomura, Hideki
    Jinno, Masafumi
    Journal of Light and Visual Environment, 2014, 38 : 66 - 78
  • [3] Energy savings in tunnel lighting by improving the road surface luminance uniformity - A new approach to tunnel lighting
    Kimura, Masayoshi
    Hirakawa, Satoshi
    Uchino, Hirohito
    Motomura, Hideki
    Jinno, Masafumi
    Journal of Light and Visual Environment, 2014, 38 : 66 - 78
  • [4] Luminance stepped decreasing ratio of the tunnel entrance enhanced lighting based on visual performance
    Kang, Cheng
    Du, Zhigang
    Lin, Guojun
    Zhang, Chi
    Huang, Zhiyi
    Wu, Ke
    APPLIED OPTICS, 2022, 61 (22) : 6553 - 6560
  • [5] LUMINANCE CALCULATIONS FOR TUNNEL LIGHTING SYSTEMS
    LEWIN, I
    HEINISCH, RV
    JOURNAL OF THE ILLUMINATING ENGINEERING SOCIETY, 1988, 17 (01): : 74 - 79
  • [6] DESIGN OF ROAD LIGHTING FOR GIVEN LUMINANCE AND UNIFORMITY
    VERMEULEN, J
    KNUDSEN, B
    PHILIPS TECHNICAL REVIEW, 1968, 29 (10): : 299 - +
  • [7] EXTENSION OF THE LUMINANCE CONCEPT IN ROAD AND TUNNEL LIGHTING
    Stockmar, Axel
    LIGHT & ENGINEERING, 2015, 23 (04): : 30 - 32
  • [8] CALCULATING AVERAGE ROAD LUMINANCE OF TUNNEL LIGHTING
    RODDEWIG, W
    STOCKMAR, A
    LICHTTECHNIK, 1977, 29 (02): : 64 - 65
  • [9] EFFECTS OF SPATIAL LUMINANCE NONUNIFORMITIES ON VISUAL-TASK PERFORMANCE AND SUBJECTIVE UNIFORMITY
    GALLIMORE, JJ
    FARLEY, WW
    SNYDER, HL
    DISPLAYS, 1991, 12 (3-4) : 147 - 155
  • [10] Study of the optical systems with illuminance and luminance uniformity simultaneously for LED lighting
    Graduate School at Shenzhen, Tsinghua University, Shenzhen
    Guangdong
    518055, China
    Guangxue Xuebao, 2