A new heating system for the air pre-purification of air separation units

被引:11
|
作者
Zhang, Peikun [1 ]
Liang, Jiayue [1 ]
Yang, Yuehan [1 ]
Wang, Li [1 ]
机构
[1] Univ Sci & Technol, Sch Energy & Environm Engn, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
Air separation unit; Air pre-purification unit; Thermal regeneration; Energy-saving; SWING ADSORPTION PROCESS; PACKED-BEDS; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2023.120194
中图分类号
O414.1 [热力学];
学科分类号
摘要
A new heating system is disclosed to reduce the regeneration heating electric consumption for air prepurification of air separation units. The new heating system is of great energy-saving significance, as air separation units are energy-intensive installations that account for a considerable proportion (around 4.97 %) of China's total national electricity consumption. Unlike the traditional electric heater, the new heating system integrates components such as a compressor, a heat exchanger, and an expander to meet the heat requirement of the pre-purification unit, while also providing cooling capacity to reduce the refrigeration load of the pre-cooling system of an air separation unit, thereby realizing the efficient comprehensive utilization of electric energy. Furthermore, a regenerator is employed to enable the continuous operation and downsizing of the system. Mathematical models were established for each process in the new heating system, and then the simulation and calculation were carried out based on the field data of an industrial-scale air separation unit. Inlet and outlet parameters and power of the compressor, expander, and heat exchanger were obtained. The temperature and pressure bed profiles of the regenerator and the temperature history curves of the cold and hot ends of the regenerator were obtained. Then, the energy-saving effect of the new heating system relative to the traditional electric heater was obtained. In addition, an economic evaluation of the new heating system was conducted based on its energy-saving effect. The conclusions drawn are as follows: compared with a traditional electric heater, the new heating system can save about 55.5 % of electric energy, and the payback period of the new heating system retrofitted from a traditional electric heater is about 2.3 years.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Waste heat recovery method for the air pre-purification system of an air separation unit
    Tong, L. G.
    Zhang, P.
    Yin, S. W.
    Zhang, P. K.
    Liu, C. P.
    Li, N.
    Wang, L.
    APPLIED THERMAL ENGINEERING, 2018, 143 : 123 - 129
  • [2] Thermal adsorptive processes for air pre-purification
    Kalbassi, MA
    Golden, TC
    SIXTH CRYOGENICS 2000, PROCEEDINGS, 2000, (06): : 103 - 108
  • [3] A new concept of air pre-purification unit for cryogenic separation: Low-pressure supersonic separator coupled to finishing adsorption
    Brigagdo, George Victor
    Arinelli, Lara de Oliveira
    de Medeiros, Jose Luiz
    Araujo, Melia de Queiroz F.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2019, 215 : 173 - 189
  • [4] New-generation air separation units
    Garin, VA
    Pisarev, YG
    CHEMICAL AND PETROLEUM ENGINEERING, 1996, 32 (01) : 57 - 64
  • [5] A NEW AIR SEPARATION SYSTEM
    MCREYNOLDS, KB
    CHEMICAL ENGINEERING PROGRESS, 1985, 81 (06) : 27 - 29
  • [6] Air Pre-Heating increases System Efficiency
    不详
    WOCHENBLATT FUR PAPIERFABRIKATION, 2014, 142 (01): : 22 - 22
  • [7] Intensifying Air Separation Units
    Manenti, Flavio
    Rossi, Francesco
    Croce, Giulia
    Grottoli, Maria G.
    Altavilla, Marcello
    16TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION (PRES'13), 2013, 35 : 1249 - 1254
  • [8] Flexible Operation of Air Separation Units
    Klein, Harald
    Fritsch, Philipp
    Haider, Patrick
    Kender, Robert
    Roessler, Felix
    Rehfeldt, Sebastian
    Freko, Pascal
    Hoffmann, Rainer
    Thomas, Ingo
    Wunderlich, Bernd
    CHEMBIOENG REVIEWS, 2021, 8 (04): : 357 - 374
  • [9] Flexible Operation of Air Separation Units
    Klein, Harald
    Fritsch, Philipp
    Haider, Patrick
    Kender, Robert
    Roessler, Felix
    Rehfeldt, Sebastian
    Freko, Pascal
    Hoffmann, Rainer
    Thomas, Ingo
    Wunderlich, Bernd
    CHEMIE INGENIEUR TECHNIK, 2020, 92 (12) : 1921 - 1940
  • [10] LARGE AIR SEPARATION UNITS PLANTS
    SPRINGMANN, H
    MECHANICAL ENGINEERING, 1975, 97 (02) : 56 - 56