Precision of Ultrasound-Guided versus Anatomical Palpation-Guided Needle Placement of the Ulnar Nerve at the Cubital Tunnel: A Cadaveric Study

被引:2
|
作者
Lopez-de-Celis, Carlos [1 ,2 ,3 ]
Fernandez-de-Las-Penas, Cesar [4 ]
Malo-Urries, Miguel [5 ]
Albarova-Corral, Isabel [5 ]
Arias-Buria, Jose L. [4 ]
Perez-Bellmunt, Albert [1 ,2 ]
Rodriguez-Sanz, Jacobo [1 ,2 ]
Gonzalez-Rueda, Vanessa [1 ,2 ,3 ]
Borella-Andres, Sergio [5 ]
机构
[1] Univ Int Catalunya, Fac Med & Hlth Sci, Barcelona 08028, Spain
[2] ACTIUM Funct Anat Grp, Barcelona 08028, Spain
[3] Univ Recerca Atencio, Fundacio Inst, Primaria Salut Jordi Gol i Gurina IDIAPJGol, Barcelona 08028, Spain
[4] Univ Rey Juan Carlos, Dept Phys Therapy Occupat Therapy Rehabil & Phys, Alcorcon 28922, Spain
[5] Univ Zaragoza, Hlth Sci Fac, Dept Physiatry & Nursery, Zaragoza 50009, Spain
关键词
needle; ultrasound; ulnar nerve; cubital tunnel; accuracy; palpation; REGIONAL ANESTHESIA; BRACHIAL-PLEXUS; STIMULATION; NEUROSTIMULATION; PAIN;
D O I
10.3390/healthcare11111603
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Percutaneous electrical stimulation has been performed for years with only the assistance of anatomical landmarks. The development of real-time ultrasonography guidance has improved the precision and safety of these percutaneous interventions. Despite ultrasound-guided and palpation-guided procedures being performed routinely for targeting nerve tissues in the upper extremity, the precision and safety of these techniques are unknown. The aim of this cadaveric study was to determine and compare the precision and safety of ultrasound-guided versus palpation-guided needling procedure with and without the handpiece of the ulnar nerve on a cadaveric model. Five physical therapists performed a series of 20 needle insertion tasks each (n = 100), 10 palpation-guided (n = 50) and 10 ultrasound-guided (n = 50) on cryopreserved specimens. The purpose of the procedure was to place the needle in proximity to the ulnar nerve at the cubital tunnel. The distance to target, time performance, accurate rate, number of passes, and unintentional puncture of surrounding structures were compared. The ultrasound-guided procedure was associated with higher accuracy (66% vs. 96%), lower distance from needle to the target (0.48 +/- 1.37 vs. 2.01 +/- 2.41 mm), and a lower frequency of perineurium puncture (0% vs. 20%) when compared with the palpation-guided procedure. However, the ultrasound-guided procedure required more time (38.33 +/- 23.19 vs. 24.57 +/- 17.84 s) than the palpation-guided procedure (all, p < 0.001). Our results support the assumption that ultrasound guidance improves the accuracy of needling procedures on the ulnar nerve at the cubital tunnel when compared with palpation guidance.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Patellar Tendon: A Cadaveric Study
    Arias-Buria, Jose L.
    Borrella-Andres, Sergio
    Rodriguez-Sanz, Jacobo
    Lopez-de-Celis, Carlos
    Malo-Urries, Miguel
    Fernandez-de-las-Penas, Cesar
    Gallego-Sendarrubias, Gracia M.
    Gonzalez-Rueda, Vanessa
    Perez-Bellmunt, Albert
    Albarova-Corral, Isabel
    LIFE-BASEL, 2023, 13 (10):
  • [2] The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical Study
    Malo-Urries, Miguel
    Borrella-Andres, Sergio
    Lopez-de-Celis, Carlos
    Fernandez-de-las-Penas, Cesar
    Perez-Bellmunt, Albert
    Arias-Buria, Jose L.
    Albarova-Corral, Isabel
    Rodriguez-Sanz, Jacobo
    HEALTHCARE, 2024, 12 (10)
  • [3] Accuracy of Ultrasound-Guided Versus Palpation-Guided Acromioclavicular Joint Injections: A Cadaveric Study
    Peck, Evan
    Lai, Jim K.
    Pawlina, Wojciech
    Smith, Jay
    PM&R, 2010, 2 (09) : 817 - 821
  • [4] RE: Accuracy of Ultrasound-Guided Versus Palpation-Guided Acromioclavicular Joint Injections: A Cadaveric Study
    Sabeti-Aschraf, Manuel
    PM&R, 2011, 3 (05) : 495 - 495
  • [5] Accuracy of Palpation-Guided and Ultrasound-Guided Needle Tip Placement Into the Deep and Superficial Posterior Leg Compartments
    Peck, Evan
    Finnoff, Jonathan T.
    Smith, Jay
    Curtiss, Heather
    Muir, Jeffery
    Hollman, John H.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (09): : 1968 - 1974
  • [6] Comparison of palpation-guided and ultrasound-guided biopsies in transplanted kidneys
    Antonopoulos, IM
    Nahas, WC
    Mazzucchi, E
    Ianhez, LE
    Saldanha, LB
    Arap, S
    CLINICAL TRANSPLANTATION, 2001, 15 (06) : 393 - 396
  • [7] Ultrasound-guided versus palpation-guided local corticosteroid injection therapy for treatment of plantar fasciitis
    Saba, Emmanuel Kamal Aziz
    El-Sherif, Sherine Mahmoud
    EGYPTIAN RHEUMATOLOGIST, 2016, 38 (02): : 123 - 131
  • [8] The Accuracy of Ultrasound-Guided and Palpation-Guided Peroneal Tendon Sheath Injections
    Muir, Jeffery J.
    Curtiss, Heather M.
    Hollman, John
    Smith, Jay
    Finnoff, Jonathan T.
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2011, 90 (07) : 564 - 571
  • [9] Ultrasound-guided thread versus ultrasound-guided needle release of the A1 pulley: a cadaveric study
    Jengojan, Suren
    Sorgo, Philipp
    Streicher, Johannes
    Snoj, Ziga
    Kasprian, Gregor
    Gruber, Gerlinde
    Bodner, Gerd
    RADIOLOGIA MEDICA, 2024, 129 (10): : 1513 - 1521
  • [10] Ultrasound-guided versus palpation-guided corticosteroid injections for tendinosis of the long head of the biceps: A randomized comparative study
    Christos K. Yiannakopoulos
    Panayiotis D. Megaloikonomos
    Konstantina Foufa
    John Gliatis
    Skeletal Radiology, 2020, 49 : 585 - 591