Fully automated film mounting in dental radiography: a deep learning model

被引:1
|
作者
Lin, Yu-Chun [1 ,2 ]
Chen, Meng-Chi [3 ]
Chen, Cheng-Hsueh [4 ]
Chen, Mu-Hsiung [5 ]
Liu, Kang-Yi [6 ]
Chang, Cheng-Chun [6 ]
机构
[1] Chang Gung Mem Hosp Linkou, Dept Med Imaging & Intervent, Taoyuan, Taiwan
[2] Chang Gung Univ, Dept Med Imaging & Radiol Sci, Taoyuan, Taiwan
[3] Chang Gung Mem Hosp Taipei, Dept Dent, Taipei, Taiwan
[4] Natl Taiwan Univ Hosp, Dept Dent, Hsin Chu Branch, Hsinchu, Taiwan
[5] Natl Taiwan Univ Hosp, Dept Dent, Taipei, Taiwan
[6] Natl Taipei Univ Technol, Dept Elect Engn, 1,Sec 3,Zhongxiao E Rd, Taipei 10608, Taiwan
关键词
Radiography; Dental; Deep learning;
D O I
10.1186/s12880-023-01064-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundDental film mounting is an essential but time-consuming task in dental radiography, with manual methods often prone to errors. This study aims to develop a deep learning (DL) model for accurate automated classification and mounting of both intraoral and extraoral dental radiography.MethodThe present study employed a total of 22,334 intraoral images and 1,035 extraoral images to train the model. The performance of the model was tested on an independent internal dataset and two external datasets from different institutes. Images were categorized into 32 tooth areas. The VGG-16, ResNet-18, and ResNet-101 architectures were used for pretraining, with the ResNet-101 ultimately being chosen as the final trained model. The model's performance was evaluated using metrics of accuracy, precision, recall, and F1 score. Additionally, we evaluated the influence of misalignment on the model's accuracy and time efficiency.ResultsThe ResNet-101 model outperformed VGG-16 and ResNet-18 models, achieving the highest accuracy of 0.976, precision of 0.969, recall of 0.984, and F1-score of 0.977 (p < 0.05). For intraoral images, the overall accuracy remained consistent across both internal and external datasets, ranging from 0.963 to 0.972, without significant differences (p = 0.348). For extraoral images, the accuracy consistently achieved the highest value of 1 across all institutes. The model's accuracy decreased as the tilt angle of the X-ray film increased. The model achieved the highest accuracy of 0.981 with correctly aligned films, while the lowest accuracy of 0.937 was observed for films exhibiting severe misalignment of & PLUSMN; 15 & DEG; (p < 0.001). The average time required for the tasks of image rotation and classification for each image was 0.17 s, which was significantly faster than that of the manual process, which required 1.2 s (p < 0.001).ConclusionThis study demonstrated the potential of DL-based models in automating dental film mounting with high accuracy and efficiency. The proper alignment of X-ray films is crucial for accurate classification by the model.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Fully automated film mounting in dental radiography: a deep learning model
    Yu-Chun Lin
    Meng-Chi Chen
    Cheng-Hsueh Chen
    Mu-Hsiung Chen
    Kang-Yi Liu
    Cheng-Chun Chang
    BMC Medical Imaging, 23
  • [2] Deep learning methods for fully automated dental age estimation on orthopantomograms
    Yuchao Shi
    Zelin Ye
    Jixiang Guo
    Yueting Tang
    Wenxuan Dong
    Jiaqi Dai
    Yu Miao
    Meng You
    Clinical Oral Investigations, 28
  • [3] Deep learning methods for fully automated dental age estimation on orthopantomograms
    Shi, Yuchao
    Ye, Zelin
    Guo, Jixiang
    Tang, Yueting
    Dong, Wenxuan
    Dai, Jiaqi
    Miao, Yu
    You, Meng
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (03)
  • [4] Deep Learning Model for Classifying Periodontitis Stages on Dental Panoramic Radiography
    Shon, Ho Sun
    Kong, Vungsovanreach
    Park, Jae Sung
    Jang, Wooyeong
    Cha, Eun Jong
    Kim, Sang-Yup
    Lee, Eun-Young
    Kang, Tae-Geon
    Kim, Kyung Ah
    APPLIED SCIENCES-BASEL, 2022, 12 (17):
  • [5] Fully automated deep learning approach to dental development assessment in panoramic radiographs
    Ong, Seung-Hwan
    Kim, Hyuntae
    Song, Ji-Soo
    Shin, Teo Jeon
    Hyun, Hong-Keun
    Jang, Ki-Taeg
    Kim, Young-Jae
    BMC ORAL HEALTH, 2024, 24 (01):
  • [6] Fully automated method for dental age estimation using the ACF detector and deep learning
    Pintana, Patipan
    Upalananda, Witsarut
    Saekho, Suwit
    Yarach, Uten
    Wantanajittikul, Kittichai
    EGYPTIAN JOURNAL OF FORENSIC SCIENCES, 2022, 12 (01)
  • [7] Fully automated method for dental age estimation using the ACF detector and deep learning
    Patipan Pintana
    Witsarut Upalananda
    Suwit Saekho
    Uten Yarach
    Kittichai Wantanajittikul
    Egyptian Journal of Forensic Sciences, 12
  • [8] URO - Fully Automated Deep Learning Model for the Detection of Prostate Cancer
    Krome, Susanne
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2025, 197 (04): : 367 - 367
  • [9] Fully automated deep learning based resolution recovery
    Andrew, Matthew
    Andreyev, Andriy
    Yang, Faguo
    Terada, Masako
    Gu, Allen
    White, Robin
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIV, 2022, 12242
  • [10] Fully Automated Deep Learning Model to Detect Clinically Significant Prostate Cancer at MRI
    Cai, Jason C.
    Nakai, Hirotsugu
    Kuanar, Shiba
    Froemming, Adam T.
    Bolan, Candice W.
    Kawashima, Akira
    Takahashi, Hiroaki
    Mynderse, Lance A.
    Dora, Chandler D.
    Humphreys, Mitchell R.
    Korfiatis, Panagiotis
    Rouzrokh, Pouria
    Bratt, Alexander K.
    Conte, Gian Marco
    Erickson, Bradley J.
    Takahashi, Naoki
    RADIOLOGY, 2024, 312 (02)