Highly Sensitive Wearable Sensor Based on (001)-Orientated TiO2 for Real-Time Electrochemical Detection of Dopamine, Tyrosine, and Paracetamol

被引:7
|
作者
Zhang, Tianyao [1 ]
Zhu, Jia [1 ,2 ,3 ]
Xie, Maowen [1 ]
Meng, Ke [1 ]
Yao, Guang [1 ]
Pan, Taisong [1 ]
Gao, Min [1 ]
Cheng, Huanyu [3 ]
Lin, Yuan [1 ,4 ]
机构
[1] Univ Elect Sci & Technol China, Sch Mat & Energy, Chengdu 610054, Peoples R China
[2] Univ Elect Sci & Technol China, Yangtze Delta Reg Inst Quzhou, Quzhou 324000, Peoples R China
[3] Penn State Univ, Dept Engn Sci & Mech, University Pk, PA 16802 USA
[4] Univ Elect Sci & Technol China, Med Engn Cooperat Appl Med Res Ctr, Chengdu 610054, Peoples R China
基金
美国国家科学基金会; 中国国家自然科学基金; 美国国家卫生研究院;
关键词
anatase TiO2; dual-channel skin patch; flexible electrochemical sensor; polymer-assisted deposition; smart diaper; DOPED GRAPHENE; ASCORBIC-ACID; URIC-ACID; SWEAT; BIOMARKERS; BIOSENSORS; NANOTUBES; COMPOSITE; ELECTRODE; DOTS;
D O I
10.1002/smll.202312238
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The concentration of dopamine (DA) and tyrosine (Tyr) reflects the condition of patients with Parkinson's disease, whereas moderate paracetamol (PA) can help relieve their pain. Therefore, real-time measurements of these bioanalytes have important clinical implications for patients with Parkinson's disease. However, previous sensors suffer from either limited sensitivity or complex fabrication and integration processes. This work introduces a simple and cost-effective method to prepare high-quality, flexible titanium dioxide (TiO2) thin films with highly reactive (001)-facets. The as-fabricated TiO2 film supported by a carbon cloth electrode (i.e., TiO2-CC) allows excellent electrochemical specificity and sensitivity to DA (1.390 mu A mu M-1 cm(-2)), Tyr (0.126 mu A mu M-1 cm(-2)), and PA (0.0841 mu A mu M-1 cm(-2)). More importantly, accurate DA concentration in varied pH conditions can be obtained by decoupling them within a single differential pulse voltammetry measurement without additional sensing units. The TiO2-CC electrochemical sensor can be integrated into a smart diaper to detect the trace amount of DA or an integrated skin-interfaced patch with microfluidic sampling and wireless transmission units for real-time detection of the sweat Try and PA concentration. The wearable sensor based on TiO2-CC prepared by facile manufacturing methods holds great potential in the daily health monitoring and care of patients with neurological disorders.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Highly sensitive electrochemical assay for selective detection of Aminotriazole based on TiO2/poly(CTAB) modified sensor
    Malode, Shweta J.
    Prabhu, K. Keerthi
    Shetti, Nagaraj P.
    Reddy, Kakarla Raghava
    ENVIRONMENTAL TECHNOLOGY & INNOVATION, 2021, 21
  • [2] A silicon-based electrochemical sensor for highly sensitive, specific, label-free and real-time DNA detection
    Guo, Yuanyuan
    Su, Shao
    Wei, Xinpan
    Zhong, Yiling
    Su, Yuanyuan
    Huang, Qing
    Fan, Chunhai
    He, Yao
    NANOTECHNOLOGY, 2013, 24 (44)
  • [3] Highly Sensitive Electrochemical Sensor for the Detection of Paracetamol in Presence of Etilefrine and Dopamine Based on Fe3O4@SiO2 Nanocomposites
    Madhuri, Chougoni
    Kiranmai, Sundupalle
    Swamy, Bahaddurghatta E. Kumara
    Padmavati, Vavilla
    Reddy, Patil Yugandhar
    Madhavi, Gajulapalli
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (10): : 1452 - 1466
  • [4] Highly sensitive electrochemical sensor for Sudan I based on graphene decorated with mesoporous TiO2
    Gan, Tian
    Sun, Junyong
    He, Manman
    Wang, Lingling
    IONICS, 2014, 20 (01) : 89 - 95
  • [5] Highly sensitive electrochemical sensor for Sudan I based on graphene decorated with mesoporous TiO2
    Tian Gan
    Junyong Sun
    Manman He
    Lingling Wang
    Ionics, 2014, 20 : 89 - 95
  • [6] Highly Sensitive and Low Detection Limit Flexible Pressure Sensor Based on Modified TiO2 Cocooned Elastic Sponge for Wearable Applications
    Xu, Zhaopeng
    Zhao, Shuai
    Lv, Xiaorong
    Ge, Xueyang
    Guo, Yongxin
    Han, Runyi
    Gong, Chenbo
    Bian, Fei
    Tian, Jifeng
    Gao, Jing
    IEEE SENSORS JOURNAL, 2022, 22 (23) : 22479 - 22486
  • [7] Electrochemical sensor for sensitive detection of bisphenol A based on molecularly imprinted TiO2 with oxygen vacancy
    Liu, Yu-Huan
    Liu, Chang
    Wang, Xin-Hui
    Li, Tong
    Zhang, Xing
    BIOSENSORS & BIOELECTRONICS, 2023, 237
  • [8] Highly sensitive detection of estradiol by a SERS sensor based on TiO2 covered with gold nanoparticles
    Brognara, Andrea
    Nasri, Ili F. Mohamad Ali
    Bricchi, Beatrice R.
    Li Bassi, Andrea
    Gauchotte-Lindsay, Caroline
    Ghidelli, Matteo
    Lidgi-Guigui, Nathalie
    BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2020, 11 : 1026 - 1035
  • [9] Photoelectrochemical sensor based on carboxylated graphdiyne co-sensitized TiO2 for sensitive detection of dopamine
    Xie, Y. Z.
    Wang, Y.
    Ma, Y.
    Ye, J. S.
    MATERIALS TODAY CHEMISTRY, 2022, 26
  • [10] Naphthalene Detection in Air by Highly Sensitive TiO2 Sensor: Real Time Response to Concentration Changes Monitored by Simultaneous UV Spectrophotometry
    Torres, Jorge H.
    Rosa, Vincent A.
    Barreto, Patricia D.
    Barreto, Jose C.
    SENSORS, 2022, 22 (19)