RELIABILITY AND VALIDITY OF THE LIE-TO-SIT-TOSTAND-TO-WALK TRANSFER TEST IN TOTAL KNEE ARTHROPLASTY

被引:0
|
作者
Unver, B. [1 ]
Kacmaz, K. S. [2 ]
Karatosun, V. [3 ]
机构
[1] Dokuz Eylul Univ, Phys Therapy & Rehabil, Izmir, Turkiye
[2] Izmir Katip Celebi Univ, Phys Therapy & Rehabil, Izmir, Turkiye
[3] Dokuz Eylul Univ, Orthoped & Traumatol, Izmir, Turkiye
关键词
Osteoarthritis; Outcome measures; Comorbidities;
D O I
10.1136/annrheumdis-2023-eular.6302
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AB1816-HPR
引用
收藏
页码:2140 / 2140
页数:1
相关论文
共 50 条
  • [1] The reliability and validity of the Lie-To-Sit-To-Stand-To-Walk transfer test in total knee arthroplasty
    Kacmaz, Kevser Sevik
    Unver, Bayram
    Karatosun, Vasfi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (08) : 3669 - 3675
  • [2] The Reliability and Validity of the Lie-to-Sit-to-Stand-to-Walk Transfer (LSSWT) Test in Knee Osteoarthritis
    Kacmaz, Kevser Sevik
    Unver, Bayram
    Karatosun, Vasfi
    INDIAN JOURNAL OF ORTHOPAEDICS, 2023, 57 (02) : 290 - 296
  • [3] The Reliability and Validity of the Lie-to-Sit-to-Stand-to-Walk Transfer (LSSWT) Test in Knee Osteoarthritis
    Kevser Sevik Kacmaz
    Bayram Unver
    Vasfi Karatosun
    Indian Journal of Orthopaedics, 2023, 57 : 290 - 296
  • [4] RELIABILITY AND VALIDITY OF THE CONE EVASION WALK TEST IN PATIENTS WITH TOTAL KNEE ARTHROPLASTY: A PILOT STUDY
    Kacmaz, K. S.
    Unver, B.
    Karatosun, V.
    ANNALS OF THE RHEUMATIC DISEASES, 2022, 81 : 1624 - 1624
  • [5] Reliability of the 6-min walk test after total knee arthroplasty
    Thomas Linding Jakobsen
    Henrik Kehlet
    Thomas Bandholm
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2625 - 2628
  • [6] Reliability of the 6-min walk test after total knee arthroplasty
    Jakobsen, Thomas Linding
    Kehlet, Henrik
    Bandholm, Thomas
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (11) : 2625 - 2628
  • [7] RELIABILITY AND VALIDITY OF THE LIE-TO-SITTO-STAND-TO-WALK TRANSFER TEST IN HIP OSTEOARTHRITIS
    Unver, B.
    Kacmaz, K. S.
    Karatosun, V.
    ANNALS OF THE RHEUMATIC DISEASES, 2023, 82 : 1040 - 1040
  • [8] Reliability and validity of the two-minute step test in patients with total knee arthroplasty
    Akkan, Hakan
    Mutlu, Ebru Kaya
    Kuyubasi, Sabit Numan
    DISABILITY AND REHABILITATION, 2024, 46 (14) : 3128 - 3132
  • [9] Reliability, validity, and minimal detectable change of the Step Test in patients with total knee arthroplasty
    Eymir, Musa
    Yuksel, Ertugrul
    Unver, Bayram
    Karatosun, Vasfi
    IRISH JOURNAL OF MEDICAL SCIENCE, 2022, 191 (06) : 2651 - 2656
  • [10] Interrater Reliability and Validity of the Stair Ascend/Descend Test in Subjects With Total Knee Arthroplasty
    Almeida, Gustavo J.
    Schroeder, Carolyn A.
    Gil, Alexandra B.
    Fitzgerald, G. Kelley
    Piva, Sara R.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 91 (06): : 932 - 938