Rotational stability and refractive outcomes of the DFT/DATx15 toric, extended depth of focus intraocular lens

被引:4
|
作者
Barber, Kevin M. [1 ]
O'Connor, Sara [1 ]
Mackinder, Philip [1 ]
Chih, Andreea [1 ]
Jones, Brian [1 ]
机构
[1] Cent Florida Eye Specialists, 968 Int Pkwy, Lake Mary, FL 32746 USA
关键词
Vivity; Extended depth of vision; Intermediate visual acuity; Corneal astigmatism correction; INTRAOPERATIVE ABERROMETRY; CATARACT-SURGERY; RESIDUAL ASTIGMATISM; AMERICAN-ACADEMY; ORIENTATION; PRESBYOPIA; IMPLANTATION; MISALIGNMENT; ALIGNMENT; FORMULAS;
D O I
10.1007/s10792-023-02673-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo quantitatively assess postoperative rotational stability and visual acuity with the DFT/DATx15 extended depth of focus (EDOF) toric intraocular lens (IOL).MethodsIn this prospective case series, thirty-five patients with a calculated IOL power between + 15.0 D and + 25.0 D, corneal astigmatism between 0.75 D and 2.25 D, and no significant ocular pathology underwent cataract surgery. Primary outcome was rotational stability of the IOL at 1 month post-operatively. Secondary outcomes included residual refractive astigmatism, absolute residual astigmatism prediction error, and monocular distance and intermediate visual acuities.ResultsMean absolute postoperative IOL rotation was 1.1 +/- 0.2 degrees, with no rotation of more than 3 degrees at the final visit. Monocular mean best spectacle-corrected distance visual acuity (BSCDVA) improved from logMAR 0.27 +/- 0.030 to 0.078 +/- 0.017 (P < .001). Monocular uncorrected distance visual acuity (UCDVA) improved from 0.93 +/- 0.096 to 0.18 +/- 0.022 (P < .001). Best spectacle-corrected intermediate visual acuity (DSCIVA) was 0.17 +/- 0.025, and uncorrected intermediate visual acuity (UCIVA) was 0.27 +/- 0.040. Residual regular astigmatic refractive error was 0.21 +/- 0.047 D.ConclusionsThe toric DFT/DATx15 EDOF lens showed excellent rotational stability and effective and predictable correction of astigmatism. Its refractive outcomes and safety profile were similar to those identified in prior studies of the non-toric DFT/DAT015 EDOF IOL. A small difference in monocular BSCDVA, of uncertain clinical significance, was found when comparing these outcomes with prior DFT/DAT015 data. The trial was retrospectively registered on November 5, 2021 (TRN NCT05119127). Plain english summaryIn cataract surgery, the natural lens of the eye is replaced with an artificial lens implant. In many cases, the patient's glasses prescription in the operated eye can be reduced or eliminated through careful choice of a lens implant. There are many types of lens implants available. Toric lens implants are used to reduce one component of the glasses prescription, called regular astigmatism (or often just "astigmatism"). To maintain the full astigmatism-reducing effect of the toric lens, the lens implant must not rotate significantly within the eye after the surgery. The DFT/DATx15 (Vivity (TM)) is a relatively new type of lens implant designed to offer patients good spectacle-free vision at far distances and improved glasses-free vision at arm's length ("intermediate") compared to a more traditional lens implant that is designed to maximize spectacle-free distance vision only. This study reports one surgeon's experience with measuring the amount of rotation of DFT/DATx15 lenses after surgery. This study also assessed the ability of the DFT/DATx15 to reduce regular astigmatism and improve glasses-free vision at far and intermediate distances. The results show that this lens did not rotate significantly within the eye and was effective at reducing the regular astigmatism as intended.
引用
收藏
页码:2737 / 2747
页数:11
相关论文
共 50 条
  • [1] Rotational stability and refractive outcomes of the DFT/DATx15 toric, extended depth of focus intraocular lens
    Kevin M. Barber
    Sara O’Connor
    Philip Mackinder
    Andreea Chih
    Brian Jones
    International Ophthalmology, 2023, 43 : 2737 - 2747
  • [2] Correction: Rotational stability and refractive outcomes of the DFT/DATx15 toric, extended depth of focus intraocular lens
    Kevin M. Barber
    Sara O’Connor
    Philip Mackinder
    Andreea Chih
    Brian Jones
    International Ophthalmology, 2023, 43 : 2749 - 2749
  • [3] Rotational stability and refractive outcomes of the DFT/DATx15 toric, extended depth of focus intraocular lens (vol 43, pg 2737, 2023)
    Barber, Kevin M. M.
    O'Connor, Sara
    Mackinder, Philip
    Chih, Andreea
    Jones, Brian
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (8) : 2749 - 2749
  • [4] Clinical Outcomes of a Refractive Extended Depth of Focus Intraocular Lens
    Orbegozo, Javier
    Perez, Angelica
    Basterra, Inaki
    Noguera, Helena
    Diaz, Sergio
    Gonzalez, Laura
    Lauzirika, Gorka
    Pinero, David P.
    JOURNAL OF REFRACTIVE SURGERY, 2025, 41 (03) : e238 - e247
  • [5] Rotational stability and refractive outcomes of a new hydrophobic acrylic toric intraocular lens
    Schartmueller, Daniel
    Lisy, Marcus
    Mahnert, Nikolaus
    Schranz, Markus
    Danzinger, Victor
    Schwarzenbacher, Luca
    Pieh, Stefan
    Abela-Formanek, Claudette
    Leydolt, Christina
    Menapace, Rupert
    EYE AND VISION, 2024, 11 (01)
  • [6] Evaluating Rotational Stability of an Extended Depth of Focus Toric Intraocular Lens Using a Slit Lamp and Image-Based Analysis
    Sandoval, Helga P.
    Lane, Stephen
    Slade, Stephen
    Donnenfeld, Eric D.
    Potvin, Richard
    Solomon, Kerry D.
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 2405 - 2410
  • [7] Refractive and Visual Outcomes After Implantation of a Secondary Sulcus Intraocular Lens with an Extended Depth of Focus
    Gundersen, Kjell Gunnar
    Potvin, Richard
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 1861 - 1869
  • [8] Tolerance to refractive error with a new extended depth of focus intraocular lens
    Black, Daniel A.
    Bala, Chandra
    Alarcon, Aixa
    Vilupuru, Srividhya
    EYE, 2024, 38 (SUPPL 1) : 15 - 20
  • [9] Rotational stability of modified toric intraocular lens
    Osawa, Ryoko
    Oshika, Tetsuro
    Sano, Masahiko
    Yuguchi, Takuma
    Kaiya, Tadayoshi
    PLOS ONE, 2021, 16 (03):
  • [10] Rotational stability and refractive outcomes of a single-piece aspheric toric intraocular lens with 4 fenestrated haptics
    Savini, Giacomo
    Alessio, Giovanni
    Perone, Giuseppe
    Rossi, Scipione
    Schiano-Lomoriello, Domenico
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (09): : 1275 - 1279