Anti-adhesive bioresorbable elastomer-coated composite hernia mesh that reduce intraperitoneal adhesions

被引:12
|
作者
Nikam, Shantanu P. [1 ,2 ]
Hsu, Yen-Hao [1 ,2 ]
Marks, Jessica R. [1 ]
Mateas, Catalin [3 ]
Brigham, Natasha C. [1 ]
McDonald, Samantha M. [1 ]
Guggenheim, Dana S. [1 ]
Ruppert, David [3 ]
Everitt, Jeffrey I. [4 ]
Levinson, Howard [3 ]
Becker, Matthew L. [1 ,5 ,6 ,7 ]
机构
[1] Duke Univ, Dept Chem, Durham, NC 27708 USA
[2] Univ Akron, Dept Polymer Sci, Akron, OH 44325 USA
[3] Duke Univ, Dept Surg, Div Plast & Reconstruct Surg, Med Ctr, Durham, NC 27710 USA
[4] Duke Univ, Dept Pathol, Durham, NC 27708 USA
[5] Duke Univ, Dept Mech Engn & Mat Sci, Durham, NC 27708 USA
[6] Duke Univ, Dept Orthopaed Surg, Durham, NC 27708 USA
[7] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
关键词
Hernia; Resorbable elastomer; Adhesions; Zwitterion; Anti; -adhesive; POLYPROPYLENE MESH; ABDOMINAL ADHESIONS; REPAIR; BIOCOMPATIBILITY; FUNCTIONALITY; BIOMATERIALS; PROSTHESIS; PREVENTION; STRATEGIES; MODEL;
D O I
10.1016/j.biomaterials.2022.121940
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intraperitoneal adhesions (IAs) are a major complication arising from abdominal repair surgeries, including hernia repair procedures. Herein, we fabricated a composite mesh device using a macroporous monofilament polypropylene mesh and a degradable elastomer coating designed to meet the requirements of this clinical application. The degradable elastomer was synthesized using an organo-base catalyzed thiol-yne addition polymerization that affords independent control of degradation rate and mechanical properties. The elastomeric coating was further enhanced by the covalent tethering of antifouling zwitterion molecules. Mechanical testing demonstrated the elastomer forms a robust coating on the polypropylene mesh does not exhibit micro-fractures, cracks or mechanical delamination under cyclic fatigue testing that exceeds peak abdominal loads (50 N/cm). Quartz crystal microbalance measurements showed the zwitterionic functionalized elastomer further reduced fibrinogen adsorption by 73% in vitro when compared to unfunctionalized elastomer controls. The elastomer exhibited degradation with limited tissue response in a 10-week murine subcutaneous implantation model. We also evaluated the composite mesh in an 84-day study in a rabbit cecal abrasion hernia adhesion model. The zwitterionic composite mesh significantly reduced the extent and tenacity of IAs by 94% and 90% respectively with respect to uncoated polypropylene mesh. The resulting composite mesh device is an excellent candidate to reduce complications related to abdominal repair through suppressed fouling and adhesion formation, reduced tissue inflammation, and appropriate degradation rate.
引用
收藏
页数:14
相关论文
共 2 条
  • [1] Endogenous stimulation-driven Janus mesh with antibacterial, anti-adhesive and prohealing performances for hernia repair
    Sun, Liwei
    Zhang, Xu
    Zhang, Jiteng
    Li, Xinmeng
    Zhao, Jie
    Jiang, Rujian
    Song, Lingjie
    Luan, Shifang
    CHEMICAL ENGINEERING JOURNAL, 2024, 494
  • [2] Chronic anemia due to transmural e-PTFE anti-adhesive barrier mesh migration in the small bowel after open incisional hernia repair: A case report
    Ceci, Francesca
    D'Amore, Linda
    Annesi, Elena
    Bambi, Lucia
    Grimaldi, Maria Romana
    Gossetti, Francesco
    Negro, Paolo
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2018, 53 : 54 - 57