Comparing Dose Calculation Algorithms for Heterogeneous Media: Analytical Anisotropic Algorithm Versus Acuros XB (Dm/Dw) With Continuous CT Value Variation

被引:0
|
作者
Yanagi, Yuya [1 ,2 ]
Kubo, Kazuki [1 ]
Ito, Takaaki [1 ]
Nakamura, Kenji [1 ]
Hirata, Makoto [1 ]
Doi, Hiroshi [3 ]
Monzen, Hajime [1 ]
机构
[1] Kindai Univ, Grad Sch Med Sci, Dept Med Phys, Osakasayama, Japan
[2] Shiga Univ Med Sci Hosp, Dept Radiol, Otsu, Japan
[3] Kindai Univ, Fac Med, Dept Radiat Oncol, Osakasayama, Japan
关键词
analytical anisotropic algorithm (aaa); heterogeneous material; hounsfield unit (hu); ct value; acuros xb (axb); DOSIMETRIC IMPACT; MONTE-CARLO; TO-MEDIUM;
D O I
10.7759/cureus.46805
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: To compare the doses calculated by the analytical anisotropic algorithm (AAA) and two dose reporting modes of Acuros XB (AXB(Dm) and AXB(Dw)) with varied CT values on the Eclipse (Varian Medical Systems, Palo Alto, CA).Materials and methods: Virtual phantoms with a central layer of heterogeneous material (thickness = 2 or 5 cm) were created with Eclipse. Using single or opposed fields, the field sizes were 5 x 5 cm(2) or 10 x 10 cm(2). The photon energies were 6 or 10 MV, and the source-to-target distance was 100 cm. The relative doses at the center of the heterogeneous material layer were evaluated with varied CT values, from-1000 to 3000 HU. Values were normalized with the dose at 0 HU (100%) for comparative analysis.Results: The results obtained from continuous data for a single field, 6 MV, 5 x 5 cm(2), and the heterogeneous material 5 cm, where the differences between algorithms were most pronounced, were as follows. In the low density region (-1000 HU and-800 HU), the dose differences for AXB with reference to AAA were, respectively,-54.5% and +4.6% (AXB(Dm)) and-47.0% and +3.5% (AXB(D-w)), and in the high-density regions (1000 HU and 3000 HU) were-5.7% and-8.8% (AXB(D-m)) and +7.4% and +3.5% (AXB(D-w)), respectively. Consequently, dose differences at arbitrary CT values could be obtained.Conclusion: Dose differences between these algorithms were clarified for heterogeneous materials. The risk of dose reduction or escalation in clinical use was clearly visible between CT values from-1000 to 3000 HU.
引用
收藏
页数:12
相关论文
共 17 条
  • [1] Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media
    Fogliata, Antonella
    Nicolini, Giorgia
    Clivio, Alessandro
    Vanetti, Eugenio
    Cozzi, Luca
    RADIATION ONCOLOGY, 2011, 6
  • [2] Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media
    Antonella Fogliata
    Giorgia Nicolini
    Alessandro Clivio
    Eugenio Vanetti
    Luca Cozzi
    Radiation Oncology, 6
  • [3] Dosimetric Evaluation with Heterogeneity in Acuros XB Advanced Dose Calculation Algorithm and Anisotropic Analytical Algorithm (AAA)
    Rana, S.
    Rogers, K.
    MEDICAL PHYSICS, 2012, 39 (06) : 3827 - 3827
  • [4] Comparison of Dose Calculation Algorithms Between Acuros XB and Anisotropic Analytical Algorithm in RapidArc Plans for High-Grade Glioma
    Takizawa, T.
    Tanabe, S.
    Utsunomiya, S.
    Kushima, N.
    Ohta, A.
    Saito, H.
    Nakano, T.
    Abe, E.
    Kaidu, M.
    Aoyama, H.
    MEDICAL PHYSICS, 2018, 45 (06) : E301 - E302
  • [5] Clinical impact of anisotropic analytical algorithm and Acuros XB dose calculation algorithms for intensity modulated radiation therapy in lung cancer patients
    Abdullah, Chaymaa
    Farag, Hamed
    El-Sheshtawy, Wael
    Aboelenein, Hassan
    Guirguis, O. W.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (06) : 1019 - 1031
  • [6] Comparing the Analytic Anisotropic Algorithm Vs. Acuros XB for Dose Calculation in the Setting of Radioablation of Ventricular Tachycardia
    Prusator, M.
    Tucker, W.
    Mazur, T.
    Hugo, G.
    Robinson, C.
    Cuculich, P.
    Knutson, N.
    MEDICAL PHYSICS, 2022, 49 (06) : E529 - E529
  • [7] Evaluating small field dosimetry with the Acuros XB (AXB) and analytical anisotropic algorithm (AAA) dose calculation algorithms in the eclipse treatment planning system
    Behinaein, Sepideh
    Osei, Ernest
    Darko, Johnson
    Charland, Paule
    Bassi, Dylan
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (04) : 353 - 364
  • [8] A comparison of two dose calculation algorithms-anisotropic analytical algorithm and Acuros XB-for radiation therapy planning of canine intranasal tumors
    Nagata, Koichi
    Pethel, Timothy D.
    VETERINARY RADIOLOGY & ULTRASOUND, 2017, 58 (04) : 479 - 485
  • [9] Dosimetric and radiobiological comparison in different dose calculation grid sizes between Acuros XB and anisotropic analytical algorithm for prostate VMAT
    Kim, Kyeong-Hyeon
    Chung, Jin-Beom
    Suh, Tae Suk
    Kang, Sang-Won
    Kang, Seong-Hee
    Eom, Keun-Yong
    Song, Changhoon
    Kim, In-Ah
    Kim, Jae-Sung
    PLOS ONE, 2018, 13 (11):
  • [10] A comparison of Monte Carlo, anisotropic analytical algorithm (AAA) and Acuros XB algorithms in assessing dosimetric perturbations during enhanced dynamic wedged radiotherapy deliveries in heterogeneous media
    Zaman, Ashfaq
    Kakakhel, Muhammad Basim
    Hussain, Amjad
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (01) : 75 - 81