Comparisons of visual outcomes between bilateral implantation and mix-and-match implantation of three types intraocular lenses

被引:3
|
作者
Ke, Shurui [1 ,2 ,3 ]
Wan, Wenjuan [1 ,2 ,3 ]
Li, Can [1 ,2 ,3 ]
机构
[1] Chongqing Med Univ, Dept Ophthalmol, Affiliated Hosp 1, Chongqing 400016, Peoples R China
[2] Chongqing Key Lab Ophthalmol, Chongqing 400016, Peoples R China
[3] Chongqing Eye Inst, Chongqing 400016, Peoples R China
关键词
Multifocal intraocular lens; Extended depth of focus intraocular lens; Dynamic visual acuity; Mix-and-match implantation; Stereopsis; Contrast sensitivity; EXTENDED-DEPTH; PATIENT SATISFACTION; IOL; PERFORMANCE; ACUITY;
D O I
10.1007/s10792-022-02513-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare binocular static visual acuity (SVA), stereopsis, contrast sensitivity (CS) and dynamic visual acuity (DVA) of 5 combinations of bifocal intraocular lenses (IOLs), trifocal IOLs and extended-depth-of-focus (EDOF) IOLs in age-related cataract patients. Methods Two hundred and ninety-two eyes of 146 patients who underwent cataract surgery in the ophthalmology department of the First Affiliated Hospital of Chongqing Medical University were involved. Subgroups included group MM (33patients, bilaterally bifocal IOL, ZMB00), group TT (31patients, bilaterally trifocal IOL, AT LISA tri839MP), group XX (34patients, bilaterally EDOF IOL, ZXR00), group MX (25patients, bifocal IOL, ZMB00 + EDOF IOL, ZXR00) and group TX (23patients, trifocal IOL, AT LISA tri839MP + EDOF IOL, ZXR00). The uncorrected SVAs (UDVA, UIVA and UNVA), uncorrected DVAs (UDDVA, UIDVA and UNDVA), near and distance stereopsis, and CS were assessed 3 months postoperatively. Results Subgroups of TT, XX, MX and TX showed better UIVA than MM (bP = 0.039, 0.021, 0.035 and 0.037, respectively). MX showed better UNVA than MM and TX (bP = 0.031 and 0.013, respectively). MX group had the optimal outcomes of both near and distance stereopsis. In the UDDVA, XX group and MX group showed better outcomes than TX group at 24 fps (frames per second) (bP = 0.019 and 0.023, respectively). XX group and MX group showed optimal outcomes at all speeds of UIDVA (P = 0.001, 0.005, 0.003 and 0.005, respectively). As the speed increased, the XX group and the MX group showed better UNDVA than the MM group and the TT group (P = 0.019, 0.002 and 0.003, respectively). Conclusions Mix-and-match implantation of bifocal IOLs and EDOF IOLs provides excellent and stable binocular visual outcomes including SVA, stereopsis and DVA in distant and near distances.
引用
收藏
页码:1143 / 1152
页数:10
相关论文
共 50 条
  • [1] Comparisons of visual outcomes between bilateral implantation and mix-and-match implantation of three types intraocular lenses
    Shurui Ke
    Wenjuan Wan
    Can Li
    International Ophthalmology, 2023, 43 : 1143 - 1152
  • [2] Comparison Between Mix-and-Match Implantation of Bifocal Intraocular Lenses and Bilateral Implantation of Trifocal Intraocular Lenses
    Bilbao-Calabuig, Rafael
    Gonzalez-Lopez, Felix
    Amparo, Ferrer
    Alvarez, Gemma
    Patel, Sunni R.
    Llovet-Osuna, Fernando
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (10) : 659 - 663
  • [3] Comparison of Visual Performance Between Mix-and-Match and Bilateral Implantation of Rotationally Asymmetric Multifocal Intraocular Lenses
    Liu, Dongle
    Li, Honglei
    Zheng, Simeng
    Sun, Jiajun
    Bai, Huiran
    Wu, Xiaoming
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 3289 - 3295
  • [4] Three Month Outcomes After Bilateral Mix-and-match Implantation of Extended Depth of Focus and Trifocal Intraocular Lenses
    Lim, Hyunah
    Lee, Ko Eun
    Jang, Joon Hyuck
    Nam, Sanghyu
    Lee, Hun
    Tchah, Hungwon
    Kim, Jae Yong
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [5] Prospective study of bilateral mix-and-match implantation of diffractive multifocal intraocular lenses in Koreans
    Chan Min Yang
    Dong Hui Lim
    Sungsoon Hwang
    Joo Hyun
    Tae-Young Chung
    BMC Ophthalmology, 18
  • [6] Prospective study of bilateral mix-and-match implantation of diffractive multifocal intraocular lenses in Koreans
    Yang, Chan Min
    Lim, Dong Hui
    Hwang, Sungsoon
    Hyun, Joo
    Chung, Tae-Young
    BMC OPHTHALMOLOGY, 2018, 18
  • [7] Six-Month Clinical Outcomes with Bilateral Mix-and-match Implantation of Extended Depth of Focus and Trifocal Intraocular Lenses
    Kim, Jae Yong
    An, Hye Rin
    Nam, Sanghyu
    Lee, Ko Eun
    Lee, Hun
    Tchah, Hungwon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [8] Comparison of Visual Outcomes and Patient Satisfaction After Bilateral Implantation of an EDOF IOL and a Mix-and-Match Approach
    Tarib, Imane
    Kasier, Insa
    Herbers, Claudia
    Hagen, Philip
    Breyer, Detlev
    Kaymak, Hakan
    Klabe, Karsten
    Lucchesi, Rafaela
    Teisch, Swetlana
    Diakonis, Vasilios F.
    Hahn, Ursula
    Fabian, Hoehn
    Kretz, Florian T. A.
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (07) : 408 - +
  • [9] Mix-and-match vs bilateral trifocal and bilateral EDOF intraocular lens implantation: the spline curve battle
    Labiris, Georgios
    Panagis, Christos
    Ntonti, Panagiota
    Konstantinidis, Aristeidis
    Bakirtzis, Minas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (02): : 167 - 173
  • [10] Clinical outcomes after mix-and-match implantation of diffractive multifocal intraocular lenses with + 2.75 and + 4.00 diopter add powers
    Jae Hyuck Lee
    Hun Lee
    Jin Ah. Lee
    Aeri Yoo
    Jae Yong Kim
    Hungwon Tchah
    BMC Ophthalmology, 20