A new compact micro-XRF spectrometer with polychromatic x-ray sample excitation

被引:2
|
作者
Wobrauschek, Peter [1 ]
Ingerle, Dieter [1 ]
Prost, Josef [1 ]
Dhara, Sangita [2 ]
Mishra, Nand Lal [2 ]
Iro, Michael [1 ]
Streli, Christina [1 ]
机构
[1] TU Wien, Atominst, Stadionallee 2, A-1020 Vienna, Austria
[2] Bhabha Atom Res Ctr, Fuel Chem Div, Mumbai, India
关键词
elemental mapping; micro-XRF; nuclear materials; toxic samples; XRF; FLUORESCENCE; BEAMLINE; OXIDE;
D O I
10.1002/xrs.3412
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A new compact micro-x-ray fluorescence (mu-XRF) spectrometer covering wide range of elements was developed and fabricated. The working capabilities of this new compact custom-made mu-XRF spectrometer are presented. The spectrometer uses a low power Rh target x-ray tube for sample excitation. Polycapillary optics focuses the polychromatic beam down to 40 mu m. The emitted radiation is measured by a peltier cooled silicon drift detector of 30 mm2 crystal size. It was observed that the polychromatic excitation provides sufficient photons for an efficient excitation of the sample to achieve good detection limit and area resolution. The detection limits are comparable with that one obtained by TXRF for a thin film sample. The advantage of the present setup, is the fact that it is suitable for specific applications for example, for radioactive and toxic samples requiring instrument adoption in glove boxes or fume hoods because of its good analytical features accompanied by simple and compact instrumentation.
引用
收藏
页码:196 / 203
页数:8
相关论文
共 50 条
  • [1] Component selection for a compact micro-XRF spectrometer
    Bichlmeier, S
    Janssens, K
    Heckel, J
    Gibson, D
    Hoffmann, P
    Ortner, HM
    X-RAY SPECTROMETRY, 2001, 30 (01) : 8 - 14
  • [2] Micro-XRF excitation in an SEM
    Haschke, M.
    Eggert, F.
    Elam, W. T.
    X-RAY SPECTROMETRY, 2007, 36 (04) : 254 - 259
  • [3] Mathematical considerations for evaluating X-ray beam size in micro-XRF analysis
    Nakae, Masanori
    Matsuyama, Tsugufumi
    Ishi, Hideyuki
    Tsuji, Kouichi
    X-RAY SPECTROMETRY, 2023, 52 (06) : 290 - 302
  • [4] Mediaeval metal threads and their identification using micro-XRF scanning, confocal XRF, and X-ray micro-radiography
    Hlozek, M.
    Trojek, T.
    Prokes, R.
    Linhart, V.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 155 : 299 - 303
  • [5] A compact 3D micro X-ray fluorescence spectrometer with X-ray tube excitation for archaeometric applications
    Mantouvalou, Ioanna
    Lange, Kathrin
    Wolff, Timo
    Groetzsch, Daniel
    Luehl, Lars
    Haschke, Michael
    Hahn, Oliver
    Kanngiesser, Birgit
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (04) : 554 - 561
  • [6] Comparative material characterization of historical and industrial samples by using a compact micro-XRF spectrometer
    Bichlmeier, S
    Janssens, K
    Heckel, J
    Hoffmann, P
    Ortner, HM
    X-RAY SPECTROMETRY, 2002, 31 (01) : 87 - 91
  • [7] Development and Applications of a Laboratory Micro X-ray Fluorescence (μXRF) Spectrometer Using Monochromatic Excitation for Quantitative Elemental Analysis
    Garrevoet, Jan
    Vekemans, Bart
    Bauters, Stephen
    Demey, Arne
    Vincze, Laszlo
    ANALYTICAL CHEMISTRY, 2015, 87 (13) : 6544 - 6552
  • [8] Development of confocal 3D micro-XRF spectrometer with dual Cr-Mo excitation
    Tsuji, Kouichi
    Nakano, Kazuhiko
    X-RAY SPECTROMETRY, 2007, 36 (03) : 145 - 149
  • [9] Development of micro X-ray fluorescence spectrometer with multi excitation sources
    Maeo, Shuji
    Sakai, Ichiro
    Kuzushita, Kaori
    Taniguchi, Kazuo
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (6-7) : 562 - 566
  • [10] A micro-XRF spectrometer based on a rotating anode generator and capillary optics
    Janssens, K
    Vekemans, B
    Vincze, L
    Adams, F
    Rindby, A
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (13) : 1661 - 1678