Inelastic cyclic response of RBS connections with jumbo sections

被引:5
|
作者
Bompa, D. V. [1 ,2 ]
Elghazouli, A. Y. [2 ]
Bogdan, T. [3 ]
Eatherthon, M. R. [4 ]
Leon, R. T. [4 ]
机构
[1] Univ Surrey, Sch Sustainabil Civil & Environm Engn, Guildford GU2 7HX, England
[2] Imperial Coll London, Dept Civil & Environm Engn, London SW7 2AZ, England
[3] ArcelorMittal Global Res & Dev Esch, Esch Sur Alzette, Luxembourg
[4] Virginia Tech, Dept Civil & Environm Engn, Blacksburg, VA USA
关键词
Reduced beam sections; Welded steel connections; Seismic design; Cyclic response; Non-linear analysis; STEEL MOMENT CONNECTIONS; TO-COLUMN CONNECTIONS; STRESS TRIAXIALITY; SEISMIC BEHAVIOR; LODE PARAMETER; DESIGN; SHEAR; FAILURE; MODEL;
D O I
10.1016/j.engstruct.2023.115758
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper examines the cyclic performance of reduced beam section (RBS) moment connections incorporating larger member sizes than those allowed in the current seismic provisions for prequalified steel connections, through experimentally validated three-dimensional nonlinear numerical assessments. Validations of the adopted nonlinear finite element procedures are carried out against experimental results from two test series, including four full-scale RBS connections comprising large structural members, outside the prequalification limits. After gaining confidence in the ability of the numerical models to predict closely the full inelastic response and failure modes, parametric investigations are undertaken. Particular attention is given to assessing the influence of the RBS-to-column capacity ratio as well as the RBS geometry and location on the overall response. The numerical results and test observations provide a detailed insight into the structural behavior, including strength, ductility, and failure modes of large RBS connections. It is shown that connections which consider sections beyond the code limits, by up to two times the weight or beam depth limits, developed a stable inelastic response characterized by beam flexural yielding and inelastic local buckling. However, connections with very large beam sections, up to three-times the typically prescribed limits, exhibited significant hardening resulting in severe demands at the welds, hence increasing susceptibility to weld fracture and propagation through the column. The findings from this study point to the need, in jumbo sections with thick flanges, for a deeper RBS cut than currently specified in design, to about 66% of the total beam width. This modification would be required to promote a response governed by extensive yielding at the RBS while reducing the excessive strain demands at the beam-to-column welds. Moreover, for connections incorporating relatively deep columns, it is shown that more stringent design requirements need to be followed, combined with appropriate bracing outside the RBS, to avoid out-of-plane rotation.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Cyclic behavior of jumbo reduced beam section connections with heavy sections: Numerical investigation
    Qi, Liangjie
    Liu, Mengda
    Shen, Zhangpeng
    Liu, Hang
    EARTHQUAKES AND STRUCTURES, 2022, 23 (02) : 183 - 196
  • [2] Effects of design factors on the cyclic response of sloped RBS moment connections
    Nia, Majid Mohammadi
    Moradi, Saber
    ENGINEERING STRUCTURES, 2020, 207
  • [3] Parametric investigation on the design of RBS moment connections with jumbo beams and columns
    Qi, Liangjie
    Leon, Roberto T.
    Eatherton, Matthew R.
    Paquette, Jonathan L.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 177
  • [4] Cyclic testing of tubular web RBS connections in deep beams
    Saleh, Aboozar
    Mirghaderi, Seyed Rasoul
    Zahrai, Seyed Mehdi
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 117 : 214 - 226
  • [5] CYCLIC INELASTIC ANALYSIS OF TUBULAR COLUMN SECTIONS
    TOMA, S
    CHEN, WF
    COMPUTERS & STRUCTURES, 1983, 16 (06) : 707 - 716
  • [6] Development of more accurate cyclic hysteretic models to represent RBS connections
    Horton, Thomas Alexander
    Hajirasouliha, Iman
    Davison, Buick
    Ozdemir, Zuhal
    Abuzayed, Ismail
    ENGINEERING STRUCTURES, 2021, 245
  • [7] Inelastic cyclic testing of welded unreinforced moment connections
    Ricles, JM
    Mao, CS
    Lu, LW
    Fisher, JW
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2002, 128 (04): : 429 - 440
  • [8] Jumbo hollow sections
    不详
    MATERIALS WORLD, 1996, 4 (06) : 316 - 316
  • [9] LOCAL BUCKLING AND INELASTIC CYCLIC BEHAVIOR OF TUBULAR SECTIONS
    SOHAL, IS
    CHEN, WF
    THIN-WALLED STRUCTURES, 1988, 6 (01) : 63 - 80
  • [10] Assessment of reduced beam section (RBS) moment connections subjected to cyclic loading
    Sofias, C. E.
    Pachoumis, D. T.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 171