Significance of body acceleration and gold nanoparticles through blood flow in an uneven/composite inclined stenosis artery: A finite difference computation

被引:15
|
作者
Raju, C. S. K. [1 ]
Basha, H. Thameem [2 ]
Noor, N. F. M. [3 ]
Shah, Nehad Ali [4 ]
Yook, Se-Jin [1 ]
机构
[1] Hanyang Univ, Sch Mech Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
[2] Ulsan Natl Inst Sci & Technol, Dept Math Sci, Ulsan, South Korea
[3] Univ Malaya, Inst Math Sci, Kuala Lumpur 50603, Malaysia
[4] Sejong Univ, Dept Mech Engn, Seoul 05006, South Korea
关键词
Pulsatile flow; Sutterby rheological model; Nanofluid; Uneven/composite inclined stenosis; Finite difference method; NANOFLUID FLOW; MAGNETIC-FIELD; PULSATILE FLOW; HEAT-TRANSFER;
D O I
10.1016/j.matcom.2023.08.006
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Stenosis is a tiny plaque-like structure that builds up in the arterial wall owing to the sediment of cholesterol, fats, and pearly substances. Such inward proliferation in arteries significantly inhibits blood flow, which leads to a lack of nutrients and oxygen in the organs. Therefore, exploring the transport characteristics of blood fluid flow in stenosis arteries plays a prominent role in enhancing blood transportation. As a result, the present mathematical model is devoted to scrutinizing the flow of Sutterby gold blood nanofluid in two distinct stenosis arteries with periodic body acceleration. It is observed that the Sutterby rheology model is treated as blood, and the single-phase model is used for exposing the nanofluid behaviour. Dimensional non-linear PDEs of the current model are reduced to the set of dimensionless PDEs with the help of non-similar variables. A finite-difference approach is manipulated to compute the dimensionless PDEs. The physical features of governing flow parameters on the Sutterby nanofluid velocity, temperature, resistance impedance, flow rate, and wall shear stress are exposed through graphs. It is found that the composite stenosis has a lower wall shear stress than the irregular stenosis. Sutterby blood nanofluid velocity is elevated with the rising of nanoparticle volume fraction. When employing a gold nanofluid containing 5% volume fraction, the temperature in the irregular artery rises by 26.004% compared to the base fluid (blood). Similarly, in the composite artery, utilizing the same 5% volume fraction of the gold nanofluid leads to a temperature increase of 32.6207%. The blood flow pattern exhibits a 0.2340% higher in the irregular artery as compared to the composite artery. & COPY; 2023 International Association for Mathematics and Computers in Simulation (IMACS). Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:399 / 419
页数:21
相关论文
共 50 条
  • [1] Finite Difference Computation of Au - Cu /Magneto-Bio-Hybrid Nanofluid Flow in an Inclined Uneven Stenosis Artery
    Basha, H. Thameem
    Rajagopal, Karthikeyan
    Ahammad, N. Ameer
    Sathish, S.
    Gunakala, Sreedhara Rao
    Complexity, 2022, 2022
  • [2] Finite Difference Computation of Au-Cu/Magneto-Bio-Hybrid Nanofluid Flow in an Inclined Uneven Stenosis Artery
    Basha, H. Thameem
    Rajagopal, Karthikeyan
    Ahammad, N. Ameer
    Sathish, S.
    Gunakala, Sreedhara Rao
    COMPLEXITY, 2022, 2022
  • [3] Unsteady flow of Casson nano-blood through uneven/composite stenosis porous artery with an inclined magnetic field
    El Glili, I.
    Saidi, A.
    Foukhari, Y.
    Driouich, M.
    Sammouda, M.
    Gueraoui, K.
    JOURNAL OF COMPUTATIONAL APPLIED MECHANICS, 2025, 56 (01): : 87 - 100
  • [4] SIGNIFICANCE OF ELECTRO-OSMOSIS FORCES AND NANOPARTICLES FOR BLOOD FLOW THROUGH AN INCLINED, POROUS-SATURATED ARTERY WITH A COMBINATION OF STENOSIS AND ANEURYSM
    El Glili, Issa
    Saidi, Abdelmajid
    Foukhari, Youness
    Driouich, Mohamed
    Sammouda, Mohamed
    JOURNAL OF POROUS MEDIA, 2025, 28 (07)
  • [5] Analysis of pulsatile blood flow through elliptical multi-stenosed inclined artery influenced by body acceleration
    Awan, Aziz Ullah
    Khalid, Muhammad Usman
    Nadeem, Sohail
    Shahzad, Muhammad Hasnain
    Ahammad, N. Ameer
    Gamaoun, Fehmi
    Hassan, Ahmed M.
    ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2023, 47
  • [6] Blood Flow through a Composite Stenosis in an Artery with Permeable Wall
    Mishra, Shailesh
    Siddiqui, S. U.
    Medhavi, Amit
    APPLICATIONS AND APPLIED MATHEMATICS-AN INTERNATIONAL JOURNAL, 2011, 6 (01): : 58 - 73
  • [7] Computational study of the pulsatile EMHD Sutterby nanofluid flow of blood through an inclined tapered porous artery having overlapping stenosis with body acceleration and slip effects
    El Glili, I.
    Driouich, M.
    ARCHIVE OF APPLIED MECHANICS, 2024, 94 (07) : 1841 - 1869
  • [8] Suspension model for blood flow through a tapering catheterized inclined artery with asymmetric stenosis
    Biswas, Devajyoti
    Paul, Moumita
    APPLICATIONS AND APPLIED MATHEMATICS-AN INTERNATIONAL JOURNAL, 2015, 10 (01): : 474 - +
  • [9] Blood flow of nanofluid through an artery with composite stenosis and permeable walls
    R. Ellahi
    S. U. Rahman
    S. Nadeem
    N. S. Akbar
    Applied Nanoscience, 2014, 4 : 919 - 926
  • [10] Blood flow of nanofluid through an artery with composite stenosis and permeable walls
    Ellahi, R.
    Rahman, S. U.
    Nadeem, S.
    Akbar, N. S.
    APPLIED NANOSCIENCE, 2014, 4 (08) : 919 - 926