Enhancing Soft Tissue Differentiation with Different Dual-Energy CT Systems: A Phantom Study

被引:0
|
作者
Gallo, Pasqualina [1 ,2 ]
D'Alessio, Andrea [3 ]
Pascuzzo, Riccardo [2 ]
Gallo, Salvatore [4 ,7 ]
Fumagalli, Maria Luisa [2 ]
Ortenzia, Ornella [5 ]
Tenconi, Chiara [6 ]
Cavatorta, Claudia [6 ]
Pignoli, Emanuele [4 ,6 ]
Ghetti, Caterina [5 ]
Bruzzone, Maria Grazia [2 ]
De Martin, Elena [2 ]
机构
[1] Human Res Ctr IRCCS, Dept Radiotherapy & Radiosurg, Via G Manzoni 56, I-20089 Milan, Italy
[2] Fdn IRCCS Ist Neurol Carlo Besta, Via G Celoria 11, I-20133 Milan, Italy
[3] Univ Hosp Maggiore Carita, Med Phys Dept, Corso G Mazzini 18, I-28100 Novara, Italy
[4] Univ Milan, Phys Dept Aldo Pontremoli, Via G Celoria 16, I-20133 Milan, Italy
[5] Univ Hosp Parma, Med Phys Dept, Via A Gramsci 14, I-43126 Parma, Italy
[6] Fdn IRCCS Ist Nazl Tumori, Med Phys Dept, Via G Venezian 1, I-20133 Milan, Italy
[7] Univ Catania, Phys & Astron Dept Ettore Majorana, Via S Sofia64, I-95125 Catania, Italy
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 05期
关键词
dual-energy CT; soft tissue; SNR; virtual monochromatic imaging; IMAGE-QUALITY; COMPUTED-TOMOGRAPHY; SPECTRAL CT; HEAD; QUANTIFICATION; PRINCIPLES; ACCURACY; IODINE; NECK;
D O I
10.3390/app14051724
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
To quantitatively evaluate the possible advantages of quantifying and differentiating various soft tissues using virtual monochromatic images (VMI) derived from different dual-energy computed tomography (DECT) technologies. This study involved four DECT scanners with different technologies. CIRS phantom images were acquired in single-energy (SECT) and DECT modes with each scanner. The analysis focused on five equivalent soft-tissue inserts: adipose, breast, liver, muscle, and bone (200 mg). The signal-to-noise ratio (SNR) was calculated for each equivalent soft-tissue insert. Finally, the contrasts of tissue pairs between DECT and SECT images were compared using Wilcoxon signed-rank tests adjusted for multiple comparisons. Average CT numbers and noise showed a significant difference pattern between DECT with respect to SECT for each CT scanner. Generally, energy levels of 70 keV or higher led to improved SNR in VMI for most of the equivalent soft-tissue inserts. However, energy levels of 40-50 keV showed significantly higher contrasts in most of the equivalent soft-tissue insert pairs. DECT images at low energies, especially at 40-50 keV, outperform SECT images in discriminating soft tissues across all four DECT technologies. The combined use of DECT images reconstructed at different energy levels provides a more comprehensive set of information for diagnostic and/or radiotherapy evaluation compared to SECT. Some differences between scanners are evident, depending on the DECT acquisition technique and reconstruction method.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Differentiation with the Dual-Energy CT
    Krome, Susanne
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (08): : 689 - 689
  • [2] Dual-energy CT: a phantom comparison of different platforms for abdominal imaging
    Thorsten Sellerer
    Peter B. Noël
    Manuel Patino
    Anushri Parakh
    Sebastian Ehn
    Sascha Zeiter
    Jasmin A. Holz
    Johannes Hammel
    Alexander A. Fingerle
    Franz Pfeiffer
    David Maintz
    Ernst J. Rummeny
    Daniela Muenzel
    Dushyant V. Sahani
    European Radiology, 2018, 28 : 2745 - 2755
  • [3] Dual-energy CT: a phantom comparison of different platforms for abdominal imaging
    Sellerer, Thorsten
    Noel, Peter B.
    Patino, Manuel
    Parakh, Anushri
    Ehn, Sebastian
    Zeiter, Sascha
    Holz, Jasmin A.
    Hammel, Johannes
    Fingerle, Alexander A.
    Pfeiffer, Franz
    Maintz, David
    Rummeny, Ernst J.
    Muenzel, Daniela
    Sahani, Dushyant V.
    EUROPEAN RADIOLOGY, 2018, 28 (07) : 2745 - 2755
  • [4] Quantification of Metal Artifact Reduction of Dual-Energy CT: A Phantom Study
    Li, K.
    Leung, W.
    MEDICAL PHYSICS, 2017, 44 (06) : 3036 - 3036
  • [5] Spectral performance of two split-filter dual-energy CT systems: A phantom study
    Greffier, Joel
    Van Ngoc Ty, Claire
    Fitton, Isabelle
    Frandon, Julien
    Beregi, Jean-Paul
    Dabli, Djamel
    MEDICAL PHYSICS, 2023, 50 (11) : 6828 - 6835
  • [6] Lower limit of iron quantification using dual-energy CT - a phantom study
    Jiang, Xia
    Hintenlang, David E.
    White, Richard D.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (01): : 299 - 307
  • [7] Robustness of radiomics among photon-counting detector CT and dual-energy CT systems: a texture phantom study
    Zhu, Lan
    Dong, Haipeng
    Sun, Jing
    Wang, Lingyun
    Xing, Yue
    Hu, Yangfan
    Lu, Junjie
    Yang, Jiarui
    Chu, Jingshen
    Yan, Chao
    Yuan, Fei
    Zhong, Jingyu
    EUROPEAN RADIOLOGY, 2025, 35 (02) : 871 - 884
  • [8] Calcium scoring with dual-energy CT in men and women: an anthropomorphic phantom study
    Li, Qin
    Liu, Songtao
    Myers, Kyle
    Gavrielides, Marios A.
    Zeng, Rongping
    Sahiner, Berkman
    Petrick, Nicholas
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [9] Accurate Multi-Material Decomposition in Dual-Energy CT: A Phantom Study
    Xue, Yi
    Jiang, Yangkang
    Yang, Chunlin
    Lyu, Qihui
    Wang, Jing
    Luo, Chen
    Zhang, Luhan
    Desrosiers, Catherine
    Feng, Kun
    Sun, Xiaonan
    Hu, Xiuhua
    Sheng, Ke
    Niu, Tianye
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2019, 5 (04) : 515 - 529
  • [10] Accuracy of dual-energy computed tomography for the quantification of iodine in a soft tissue-mimicking phantom
    Li, Jung-Hui
    Du, Yeh-Ming
    Huang, Hsuan-Ming
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (05): : 418 - 426