Continuous Glucose Monitoring to Optimize Management of Diabetes in Patients with Advanced CKD

被引:23
|
作者
Galindo, Rodolfo J. J. [1 ,7 ]
Boer, Ian H. de H. [2 ]
Neumiller, Joshua J. J. [3 ]
Tuttle, Katherine R. R. [4 ,5 ,6 ]
机构
[1] Emory Univ, Sch Med, Div Endocrinol, Atlanta, GA USA
[2] Univ Washington, Kidney Res Inst, Seattle, WA USA
[3] Washington State Univ, Coll Pharm & Pharmaceut Sci, Dept Pharmacotherapy, Spokane, WA USA
[4] Univ Washington, Kidney Res Inst, Nephrol Div, Seattle, WA USA
[5] Univ Washington, Inst Translat Hlth Sci, Seattle, WA USA
[6] Providence Hlth Care, Providence Med Res Ctr, Spokane, WA USA
[7] Emory Univ, Sch Med, 69 Jesse Hill Jr Dr,Glenn Bldg,Suite 202, Atlanta, GA 30303 USA
关键词
chronic dialysis; chronic kidney disease; diabetes; diabetes mellitus; end-stage renal disease; continuous glucose monitoring; CGM; STAGE RENAL-DISEASE; DAILY INSULIN INJECTIONS; QUALITY-OF-LIFE; KIDNEY-DISEASE; SENSING TECHNOLOGY; COMPLICATIONS TRIAL/EPIDEMIOLOGY; GLYCEMIC CONTROL; INHIBITORS; US ADULTS; TYPE-1;
D O I
10.2215/CJN.04510422
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Treatment of patients with diabetes and CKD includes optimizing glycemic control using lifestyle modifications and drugs that safely control glycemia and improve clinical kidney and cardiovascular disease outcomes. However, patients with advanced CKD, defined as eGFR <30 ml/min per 1.73 m(2) or kidney disease treated with dialysis, have limitations to the use of some preferred glucose-lowering medications, are often treated with insulin, and experience high rates of severe hypoglycemia. Moreover, hemoglobin A1c accuracy decreases as GFR deteriorates. Hence, there is a need for better glycemic monitoring tools. Continuous glucose monitoring allows for 24-hour glycemic monitoring to understand patterns and the effects of lifestyle and medications. Real-time continuous glucose monitoring can be used to guide the administration of insulin and noninsulin therapies. Continuous glucose monitoring can overcome the limitations of self-monitored capillary glucose testing and hemoglobin A1c and has been shown to prevent hypoglycemic excursions in some populations. More data are needed to understand whether similar benefits can be obtained for patients with diabetes and advanced CKD. This review provides an updated approach to management of glycemia in advanced CKD, focusing on the role of continuous glucose monitoring in this high-risk population.
引用
收藏
页码:130 / 145
页数:16
相关论文
共 50 条
  • [1] Continuous Glucose Monitoring Metrics in the Assessment of Glycemia in Moderate-to-Advanced CKD in Diabetes
    Ling, James
    Ng, Jack K. C. Chung
    Lau, Eric S. H.
    Ma, Ronald C. W.
    Kong, Alice P. S.
    Luk, Andrea O. Y.
    Kwok, Jeffrey S. S.
    Szeto, Cheuk-Chun
    Chan, Juliana C. N.
    Chow, Elaine
    KIDNEY INTERNATIONAL REPORTS, 2022, 7 (06): : 1354 - 1363
  • [2] Frequency of Hypoglycemia Assessed by Continuous Glucose Monitoring in Advanced CKD
    Ushiogi, Yasuyuki
    Kanehara, Hideo
    Kato, Tamayo
    CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2023, 18 (04): : 475 - 484
  • [3] Continuous Glucose Monitoring and Glycemic Control in Patients With Type 2 Diabetes Mellitus and CKD
    Presswala, Lubaina
    Hong, Susana
    Harris, Yael
    Romao, Isabela
    Zhang, Meng
    Jhaveri, Kenar D.
    Sakhiya, Vipul
    Fishbane, Steven
    KIDNEY MEDICINE, 2019, 1 (05) : 281 - 287
  • [4] Continuous Glucose Monitoring and Reduced Diabetes-Related Hospitalizations in Patients with Type 2 Diabetes and CKD
    Hannah, Katia L.
    Nemlekar, Poorva M.
    Johnson, Matthew L.
    Chernavvsky, Daniel R.
    Norman, Gregory J.
    KIDNEY360, 2024, 5 (04): : 515 - 521
  • [5] Advanced Diabetes Management Using Artificial Intelligence and Continuous Glucose Monitoring Sensors
    Vettoretti, Martina
    Cappon, Giacomo
    Facchinetti, Andrea
    Sparacino, Giovanni
    SENSORS, 2020, 20 (14) : 1 - 18
  • [6] Role of continuous glucose monitoring in diabetes management
    Moser, E. G.
    Crew, L. B.
    Garg, S. K.
    AVANCES EN DIABETOLOGIA, 2010, 26 (02): : 73 - 78
  • [7] Continuous Glucose Monitoring: Review of an Innovation in Diabetes Management
    Mian, Zainab
    Hermayer, Kathie L.
    Jenkins, Alicia
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2019, 358 (05): : 332 - 339
  • [8] Continuous Glucose Monitoring for Diabetes Management During Pregnancy
    Battarbee, Ashley N.
    Durnwald, Celeste
    Yee, Lynn M.
    Valent, Amy M.
    OBSTETRICS AND GYNECOLOGY, 2024, 144 (05): : 649 - 659
  • [9] Continuous Glucose Monitoring in Patients With Type 2 Diabetes
    Beck, R. W.
    Riddlesworth, T. D.
    Ruedy, K.
    Ahmann, A.
    Haller, S.
    Kruger, D.
    McGill, J. B.
    Polonsky, W.
    Price, D.
    Aronoff, S.
    Aronson, R.
    Toschi, E.
    Kollman, C.
    Bergenstal, R.
    ANNALS OF INTERNAL MEDICINE, 2017, 167 (06) : I20 - I20
  • [10] Accuracy of Continuous Glucose Monitoring in Hemodialysis Patients With Diabetes
    Narasaki, Yoko
    Kalantar-Zadeh, Kamyar
    Daza, Andrea C.
    You, Amy S.
    Novoa, Alejandra
    Peralta, Renal Amel
    Siu, Man Kit Michael
    Nguyen, Danh V.
    Rhee, Connie M.
    DIABETES CARE, 2024, 47 (11)