Nebulization of model hydrogel nanoparticles to macrophages at the air-liquid interface

被引:2
|
作者
Sudduth, Emma R. [1 ]
Kolewe, Emily L. [1 ]
Graf, Jodi [1 ]
Yu, Yinkui [1 ]
Somma, Joaquina [1 ]
Fromen, Catherine A. [1 ]
机构
[1] Univ Delaware, Dept Chem & Biomol Engn, Newark, DE 19716 USA
来源
FRONTIERS IN CHEMICAL ENGINEERING | 2023年 / 4卷
基金
美国国家卫生研究院;
关键词
aerosol; nebulizer; PEGDA (poly(ethylene glycol) diacrylate); nanoparticle; air-liquid interface (ALI); surface charge; CELLULAR UPTAKE; SURFACE-CHARGE; IN-VITRO; PULMONARY; CELLS; LUNG; PARTICLES; TRAFFICKING; CIRCULATION; DEPOSITION;
D O I
10.3389/fceng.2022.1086031
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction: Nanoparticle evaluation within the pulmonary airspace has increasingly important implications for human health, with growing interest from drug delivery, environmental, and toxicology fields. While there have been widespread investigations of nanoparticle physiochemical properties following many routes of administration, nanoparticle behavior at the air-liquid interface (ALI) is less well-characterized. Methods: In this work, we fabricate two formulations of poly(ethylene)-glycol diacrylate (PEGDA)-based model nanoparticles to establish an in vitro workflow allowing evaluation of nanoparticle charge effects at the ALI. Results and Discussion: Both cationic and anionic PEGDA formulations were synthesized with similar hydrodynamic diameters around 225 nm and low polydispersity, with expected surface charges corresponding with the respective functional co-monomer. We find that both formulations are readily nebulized from an aqueous suspension in a commercial Aeroneb (R) Lab Nebulizer, but the aqueous delivery solution served to slightly increase the overall hydrodynamic and geometric size of the cationic particle formulation. However, nanoparticle loading at 50 mu g/ml of either formulation did not influence the resultant aerosol diameter from the nebulizer. To assess aerosol delivery in vitro, we designed a 3D printed adapter capable of ensuring aerosol delivery to transwell 24-well culture plates. Nanoparticle uptake by macrophages was compared between traditional cell culture techniques and that of air-liquid interface-cultured macrophages following aerosol delivery. Cell viability was unaffected by nanoparticle delivery using either method. However, only traditional cell culture methods demonstrated significant uptake that was dependent on the nanoparticle surface charge. Concurrently, air-liquid interface culture resulted in lower metabolic activity of macrophages than those in traditional cell culture, leading to lower overall nanoparticle uptake at air-liquid interface. Overall, this work demonstrates that base-material similarities between both particle formulations provide an expected consistency in aerosol delivery regardless of the nanoparticle surface charge and provides an important workflow that enables a holistic evaluation of aerosolizable nanoparticles.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Toxicity of Silver Nanoparticles at the Air-Liquid Interface
    Holder, Amara L.
    Marr, Linsey C.
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [2] Interactions of insoluble micro- and nanoparticles with the air-liquid interface of the model pulmonary fluids
    Dobrowolska, Katarzyna
    Jablczynska, Katarzyna
    Kondej, Dorota
    Sosnowski, Tomasz R.
    PHYSICOCHEMICAL PROBLEMS OF MINERAL PROCESSING, 2018, 54 (01): : 151 - 162
  • [3] DNA damage of macrophages induced by metal nanoparticulates using an air-liquid interface exposure model
    Grigg, Jonathan
    Tellabati, Ananth
    Jones, George D. D.
    Howes, Paul
    NANOTOXICOLOGY, 2013, 7 (05) : 961 - 962
  • [4] Collection of nanoparticles at the air-liquid interface by surface tension gradients
    Liu, Dong
    Weng, Ding
    Wang, Jiadao
    COLLOID AND INTERFACE SCIENCE COMMUNICATIONS, 2019, 33
  • [5] Swimming of a model ciliate near an air-liquid interface
    Wang, S.
    Ardekani, A. M.
    PHYSICAL REVIEW E, 2013, 87 (06):
  • [6] Effects and uptake of gold nanoparticles deposited at the air-liquid interface of a human epithelial airway model
    Brandenberger, C.
    Rothen-Rutishauser, B.
    Muehlfeld, C.
    Schmid, O.
    Ferron, G. A.
    Maier, K. L.
    Gehr, P.
    Lenz, A. -G.
    TOXICOLOGY AND APPLIED PHARMACOLOGY, 2010, 242 (01) : 56 - 65
  • [7] Catalytic Microstrider at the Air-Liquid Interface
    Solovev, Alexander A.
    Mei, Yongfeng
    Schmidt, Oliver G.
    ADVANCED MATERIALS, 2010, 22 (39) : 4340 - +
  • [8] KERATINOCYTES GROWN AT THE AIR-LIQUID INTERFACE
    BERNSTAM, LI
    VAUGHAN, FL
    BERNSTEIN, IA
    IN VITRO CELLULAR & DEVELOPMENTAL BIOLOGY, 1986, 22 (12): : 695 - 705
  • [9] Colloidal interaction at the air-liquid interface
    Martínez-López, E
    Cabrerizo-Vílchez, MA
    Hidalgo-Alvarez, R
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2000, 232 (02) : 303 - 310
  • [10] Dynamic printing at the air-liquid interface
    Bakhshandeh, Sadra
    NATURE REVIEWS BIOENGINEERING, 2025, 3 (02): : 106 - 106