Toward local core outlet temperature monitoring in gas-cooled nuclear reactors using distributed fiber-optic temperature sensors

被引:9
|
作者
Hyer, Holden C. [1 ]
Giuliano, Dominic R. [1 ]
Petrie, Christian M. [1 ]
机构
[1] Oak Ridge Natl Lab, Oak Ridge, TN 37830 USA
关键词
Nuclear power; Fiber-optic; Gas-cooled reactor; Temperature sensor; Distributed sensing; SILICA OPTICAL-FIBERS; RADIATION-INDUCED ATTENUATION; HIGH-SPATIAL-RESOLUTION; RAYLEIGH BACKSCATTER; OPERATING EXPERIENCE; POWER; GAMMA; FLOW; AVR; NANOFLUID;
D O I
10.1016/j.applthermaleng.2023.120847
中图分类号
O414.1 [热力学];
学科分类号
摘要
Gas-cooled nuclear reactors operate at temperatures up to 950 degrees C with significant spatial variations in power generation and coolant flow through hundreds of parallel flow channels, resulting in complex mixing at the core outlet. The high temperatures and complex mixing can damage downstream components, challenge reactor calorimetry for power determination, and result in significant conservatism in calculated peak fuel temperatures, which ultimately limits the total power output. Directly measuring each gas stream individually is unrealistic using single point thermocouples, requiring more robust sensing techniques. Fiber-optic sensors are resilient to high temperatures (up to 1,000 degrees C) and radiation damage. Moreover, distributed measurements can be made along the length of one fiber, making them potential candidates for monitoring local core outlet temperatures to improve core calorimetry and identify hot channels. To the authors' knowledge, this manuscript is the first to report spatially distributed fiber optic temperature measurements to quantify mixing at the outlet of a relevant orifice plate under prototypic temperature and flow regimes to assess the feasibility of using fiber-optic sensors for distributed measurements of coolant temperature in gas-cooled reactors. A single optical fiber captured dynamic changes in local temperatures, whereas the mixed outlet temperature exhibited a muted response and could not identify which channels were responsible for the change in the mixed outlet temperature. The discussion focuses on potential challenges for deploying distributed optical fibers in gas-cooled reactors, including the effects of vibrations, radiation-induced signal attenuation and drift, and routing of the fiber while minimizing flow obstructions.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] HIGH TEMPERATURE GAS-COOLED NUCLEAR REACTORS
    SIMON, RH
    GITTERMA.M
    WEBB, GB
    CHEMICAL ENGINEERING PROGRESS, 1965, 61 (11) : 78 - &
  • [2] Nuclear graphite for high temperature gas-cooled reactors
    Zhou Xiang-wen
    Tang Ya-ping
    Lu Zhen-ming
    Zhang Jie
    Liu Bing
    NEW CARBON MATERIALS, 2017, 32 (03) : 193 - 204
  • [3] Optical fiber semiconductor absorption temperature sensor for temperature monitoring in a gas-cooled nuclear reactor
    Berghmans, F
    Vos, F
    Decreton, M
    vandenDurpel, L
    Marloye, D
    Verwimp, I
    FIBER OPTIC AND LASER SENSORS XIV, 1996, 2839 : 182 - 190
  • [4] EMERGENCY CORE COOLING FOR HIGH-TEMPERATURE GAS-COOLED REACTORS
    GOODJOHN, AJ
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1968, 11 (01): : 258 - &
  • [5] Power cycle assessment of nuclear high temperature gas-cooled reactors
    Herranz, L. E.
    Linares, J. I.
    Moratilla, B. Y.
    APPLIED THERMAL ENGINEERING, 2009, 29 (8-9) : 1759 - 1765
  • [6] Small high temperature gas-cooled reactors with innovative nuclear burning
    Liem, Peng Hong
    Ismail
    Sekimoto, Hiroshi
    PROGRESS IN NUCLEAR ENERGY, 2008, 50 (2-6) : 251 - 256
  • [7] A DESIGN METHOD TO ISOTHERMALIZE THE CORE OF HIGH-TEMPERATURE GAS-COOLED REACTORS
    TAKANO, M
    SAWA, K
    NUCLEAR TECHNOLOGY, 1987, 78 (03) : 207 - 215
  • [8] Hydrogen production by using high-temperature gas-cooled reactors
    Boretti, Alberto
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (21) : 7938 - 7943
  • [10] Local measurement of gas temperature with an infrared fiber-optic probe
    Clausen, S
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (06) : 888 - 896