Study of combined heat and power plant integration with thermal energy storage for operational flexibility

被引:37
|
作者
Chen, Chengxu [1 ]
Ge, Zhihua [1 ]
Zhang, Youjun [1 ]
机构
[1] North China Elect Power Univ, Key Lab Power Stn Energy Transfer Convers & Syst, Minist Educ, Beijing 102206, Peoples R China
关键词
Combined heat and power; Thermal energy storage; Power plant flexibility; Thermodynamic analysis; Peak shaving capacity; COMPREHENSIVE ANALYSIS; GENERATION SYSTEM; EXERGY ANALYSIS; ELECTRIC-POWER; FEEDWATER; SOLAR; OPTIMIZATION; PERFORMANCE; COGENERATION; TECHNOLOGIES;
D O I
10.1016/j.applthermaleng.2022.119537
中图分类号
O414.1 [热力学];
学科分类号
摘要
Increasing the share of renewable energy in the future electricity market requires measures to maintain the stability of the grid, owing to the volatility and intermittency of renewable energy. For a combined heat and power (CHP) plant, molten salt thermal energy storage (TES) can be added to improve the flexibility to meet the needs of peak shaving. This paper proposed a novel cascade reheat steam extraction system to adjust the elec-trical load by using EBSILON software applied to thermal simulation and thermal analysis. A 350 MW super-critical CHP plant was used as an example to analyze the thermal and peak shaving performance under variable operating conditions. Meanwhile, through the static simulation, the change in the load and the efficiency of TES can be calculated during the charging and discharging cycle. The results show that the efficiency of TES is 40-51 %. With an increase in the load, the efficiency of TES is reduced, and the exergy loss range is from 4 MW to 12.4 MW mainly due to the throttling process and the molten salt heat transfer process. Moreover, the thermal ef-ficiency and exergy efficiency of the novel system are higher than those of the traditional CHP plant below 60 % turbine heat acceptance, so it is relatively economical to run for peak shaving under low loads. Finally, depending on the corresponding operating strategy, a reduction of the minimum load by up to 1 % of the rated output electrical load during charging and an increase of the maximum load by up to 2 % of the rated output electrical load during discharging are possible. Overall, the proposed system provides a feasible method for the flexibilization of CHP plants alongside new renewable systems.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Integration of Thermal Energy Storage Systems for Improved Efficiency and Flexibility of the Combined Heat and Power Plants of Medium and Small Power
    Atanasoae, Pavel
    Pentiuc, Radu
    Bobric, Crenguta
    Olariu, Elena
    Martin, Valentin
    2017 INTERNATIONAL CONFERENCE ON ELECTROMECHANICAL AND POWER SYSTEMS (SIELMEN), 2017, : 212 - 215
  • [2] Increasing the flexibility of combined heat and power plants with heat pumps and thermal energy storage
    Mollenhauer, Eike
    Christidis, Andreas
    Tsatsaronis, George
    ECOS 2016 - Proceedings of the 29th International Conference on Efficiency, Cost, Optimisation, Simulation and Environmental Impact of Energy Systems, 2016,
  • [3] Increasing the Flexibility of Combined Heat and Power Plants With Heat Pumps and Thermal Energy Storage
    Mollenhauer, Eike
    Christidis, Andreas
    Tsatsaronis, George
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2018, 140 (02):
  • [4] Assessing the Operational Flexibility in Power Systems with Energy Storage Integration
    Tziovani, Lysandros
    Savva, Maria
    Asprou, Markos
    Kolios, Panayiotis
    Kyriakides, Elias
    Tapakis, Rogiros
    Michael, Michalis
    Hadjilaou, Christos
    FLEXITRANSTORE, 2020, 610 : 1 - 12
  • [5] Flexibility of a combined heat and power system with thermal energy storage for district heating
    Nuytten, Thomas
    Claessens, Bert
    Paredis, Kristof
    Van Bael, Johan
    Six, Daan
    APPLIED ENERGY, 2013, 104 : 583 - 591
  • [6] Integration of compressed air energy storage into combined heat and power plants: A solution to flexibility and economy
    Wang, Congyu
    Song, Jiwei
    Zheng, Wei
    Zhu, Lingkai
    Guo, Junshan
    Wang, Wenxing
    ENERGY CONVERSION AND MANAGEMENT, 2023, 290
  • [7] Modeling of combined heat and power plant performance with seasonal thermal energy storage
    McDaniel, Benjamin
    Kosanovic, Dragoljub
    JOURNAL OF ENERGY STORAGE, 2016, 7 : 13 - 23
  • [8] Integration of Battery Energy Storage in Thermal Power Plant
    Vins, Martin
    Dragoun, Jaroslav
    Sirovy, Martin
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 1608 - 1613
  • [9] Combined heat and power operational modes for increased product flexibility in a waste incineration plant
    Beiron, Johanna
    Montanes, Ruben M.
    Normann, Fredrik
    Johnsson, Filip
    ENERGY, 2020, 202
  • [10] COMBINED HEAT AND POWER GAS TURBINE OPERATIONAL FLEXIBILITY
    DiCampli, James
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2013, VOL 4, 2013,