Numerical Simulation of the Blast Resistance of SPUA Retrofitted CMU Masonry Walls

被引:6
|
作者
Zhang, Yi [1 ]
Hu, Jiahui [2 ]
Zhao, Wenda [3 ]
Hu, Feng [1 ]
Yu, Xiao [1 ]
机构
[1] PLA, Inst Def Engn, AMS, Beijing 100850, Peoples R China
[2] Tongji Univ, Coll Civil Engn, Shanghai 200092, Peoples R China
[3] China Construct Engn Bur Co Ltd, Shanghai 200122, Peoples R China
基金
中国国家自然科学基金;
关键词
far-range explosion; numerical simulation; masonry walls; sprayed polyurea; dynamic response;
D O I
10.3390/buildings13020446
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Through numerical simulation, the blast-resistant performance of spray polyurea elastomer (SPUA) retrofitted concrete masonry unit (CMU) masonry infill walls under far-range blast loading was studied. From an engineering perspective, the effects of boundary conditions and thickness of a SPUA layer on enhancing the blast resistance of masonry infill walls are discussed, and the blast resistance of SPUA-retrofitted and grouted CMU masonry infill walls are compared. It is concluded that the boundary constraint conditions and the anchorage length of SPUA layer have limited improvement on the blast-resistant performance of the wall; the thickness of SPUA layer can significantly improve the blast-resistant performance of the wall as the blast loading increases. In addition, SPUA retrofitting shows relatively better performance to reinforce masonry infill walls.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Simulation of Retrofitted Unreinforced Concrete Masonry Unit Walls under Blast Loading
    Aghdamy, Sanam
    Wu, Chengqing
    Griffith, Michael
    INTERNATIONAL JOURNAL OF PROTECTIVE STRUCTURES, 2013, 4 (01) : 21 - 44
  • [2] Numerical simulation of Masonry Walls Subjected to Blast Loads
    Yuan, Xiaojun
    Chen, Li
    Wu, Jianhua
    Tang, Jingxin
    ADVANCED BUILDING MATERIALS AND STRUCTURAL ENGINEERING, 2012, 461 : 93 - +
  • [3] Numerical simulation of masonry walls retrofitted by prefabricated reinforced concrete panels
    Zhang, Yongqun
    Wang, Tao
    ADVANCES IN CIVIL STRUCTURES, PTS 1 AND 2, 2013, 351-352 : 1514 - 1518
  • [4] Dynamic Response of Retrofitted Masonry Walls for Blast Loading
    Urgessa, Girum S.
    Maji, Arup K.
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 2010, 136 (07): : 858 - 864
  • [5] Blast response of polymer-retrofitted masonry unit walls
    Wang, Junguo
    Ren, Huiqi
    Wu, Xiangyun
    Cai, Canliu
    COMPOSITES PART B-ENGINEERING, 2017, 128 : 174 - 181
  • [6] Numerical analysis on blast-resistant capacity of masonry walls retrofitted with elastomeric polymer and CFRP
    Xu, San-Luo
    Fang, Qin
    Jiefangjun Ligong Daxue Xuebao/Journal of PLA University of Science and Technology (Natural Science Edition), 2010, 11 (03): : 306 - 311
  • [7] Behaviour of retrofitted masonry walls subjected to blast loading: Damage assessment
    Chiquito, M.
    Lopez, L. M.
    Castedo, R.
    Perez-Caldentey, A.
    Santos, A. P.
    ENGINEERING STRUCTURES, 2019, 201
  • [8] Response of 1/4-scale concrete masonry unit (CMU) walls to blast
    Dennis, ST
    Baylot, JT
    Woodson, SC
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 2002, 128 (02): : 134 - 142
  • [9] NUMERICAL SIMULATION OF CFRP STRENGTHENED PERFORATED MASONRY WALLS UNDER BLAST LOADING
    Guo, Yurong
    Zheng, Hong
    INNOVATION & SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2011, : 1060 - 1064
  • [10] Response of 1/4-scale concrete masonry unit (CMU) walls to blast
    Dennis, Scott T.
    Baylot, James T.
    Woodson, Stanley C.
    American Society of Mechanical Engineers, Pressure Vessels and Piping Division (Publication) PVP, 2000, 414 : 251 - 261