Test-retest reliability of quantitative sensory testing, active joint position sense, and functional hop testing in amateur adult athletes with unilateral anterior cruciate ligament reconstruction

被引:1
|
作者
Kempfert, David J. [1 ]
Chaconas, Eric J. [2 ]
Daugherty, Matthew L. [1 ]
Clark, Nicholas C. [3 ]
机构
[1] Univ St Augustine Hlth Sci, Coll Rehabil Sci, St Augustine, FL 32086 USA
[2] Bellin Coll, Sci Phys Therapy Program, 3201 Eaton Rd, Green Bay, WI 54311 USA
[3] Univ Essex, Sch Sport Rehabil & Exercise Sci, Wivenhoe Pk, Colchester C04 3SQ, Essex, England
关键词
Knee; Anterior cruciate ligament; Quantitative sensory testing; Proprioception; INJURY SURVEILLANCE SYSTEM; PLANTAR CUTANEOUS SENSITIVITY; ACL INJURY; KNEE PROPRIOCEPTION; SENSORIMOTOR SYSTEM; DESCRIPTIVE EPIDEMIOLOGY; VIBRATORY PERCEPTION; MEASUREMENT ERROR; SPORTS; PAIN;
D O I
10.1016/j.ptsp.2023.09.007
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: The somatosensory system fulfils a critical role in functional knee joint stability (FKJS) by providing afferent feedback necessary for neuromuscular control. Individuals with anterior cruciate ligament reconstruction (ACLr) have altered somatosensory function. Somatosensory characteristics are assessed by proprioception and quantitative sensory testing. The purpose of the study was to examine intra-rater and inter-rater reliability of methods used to assess somatosensory characteristics and FKJS in amateur adult athletes with unilateral ACLr.Design: Repeated measures.Setting: University.Participants: 8 female, 4 male with unilateral autogenous ACLr.Main outcome measures: Bilateral measurements at 5 lower extremity locations and the anterior forearm: light touch (LT), vibration sense (VS), pressure pain threshold (PPT); knee active joint position sense (AJPS); adapted crossover hop for distance (ACHD). Intraclass correlation coefficients (ICC) determined reliability, defined as: poor (<0.50), moderate (0.50-0.75), good (0.75-0.90).Results: ACLr-side intra-rater/inter-rater ICCs ranged: LT, -0.27-0.80/-0.01-0.84; VS, 0.12-0.90/0.25-0.90; PPT, 0.49-0.98/0.86-0.99; AJPS, 0.15-0.79/0.55-0.87; ACHD, 0.98/0.99. Uninjured-side intra-rater/inter-rater ICCs ranged: LT, 0.12-0.66/-0.09-0.64; VS, 0.35-0.89/0.05-0.81; PPT, 0.65-0.99/0.45-0.95; AJPS, 0.07-0.81/ 0.37-0.99; ACHD, 0.99/0.98.Conclusions: Intra-rater and inter-rater reliability was poor to good for both limbs. Overall, PPT and the ACHD demonstrated the highest ICCs. Some somatosensory assessments can be employed with confidence, while others should be used with caution.
引用
收藏
页码:63 / 73
页数:11
相关论文
共 25 条
  • [1] Test-retest reliability of knee rating scales and functional hop tests one year following anterior cruciate ligament reconstruction
    Hopper, DM
    Goh, SC
    Wentworth, LA
    Chan, DYK
    Chau, JHW
    Wootton, GJ
    Strauss, GR
    Boyle, JJW
    PHYSICAL THERAPY IN SPORT, 2002, 3 (01) : 10 - 18
  • [2] A hop testing alternative for functional performance following anterior cruciate ligament reconstruction
    Ripic, Zachary
    Letter, Michael
    Schoenwether, Brandon
    Kaplan, Lee D.
    Baraga, Michael G.
    Costello, Joseph P.
    Eskenazi, Jordan
    Dennison, Molly
    Best, Thomas M.
    Signorile, Joseph F.
    Eltoukhy, Moataz
    PLOS ONE, 2024, 19 (08):
  • [3] Test-retest reliability of Quantitative Sensory Testing in knee osteoarthritis and healthy participants
    Wylde, V.
    Palmer, S.
    Learmonth, I. D.
    Dieppe, P.
    OSTEOARTHRITIS AND CARTILAGE, 2011, 19 (06) : 655 - 658
  • [4] Functional assessment of knee joint position sense following anterior cruciate ligament reconstruction
    Mir, S. M.
    Hadian, M-R
    Talebian, S.
    Nasseri, N.
    BRITISH JOURNAL OF SPORTS MEDICINE, 2008, 42 (04) : 300 - 303
  • [5] Functional measurement of knee joint position sense after anterior cruciate ligament reconstruction
    Hopper, DM
    Creagh, MJ
    Formby, PA
    Goh, SC
    Boyle, JJ
    Strauss, GR
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2003, 84 (06): : 868 - 872
  • [6] Test-retest Agreement and Reliability of Quantitative Sensory Testing 1 Year After Breast Cancer Surgery
    Andersen, Kenneth Geving
    Kehlet, Henrik
    Aasvang, Eske Kvanner
    CLINICAL JOURNAL OF PAIN, 2015, 31 (05): : 393 - 403
  • [7] Test-retest reliability of quantitative sensory testing for mechanical somatosensory and pain modulation assessment of masticatory structures
    Costa, Y. M.
    Morita-Neto, O.
    de Araujo-Junior, E. N. S.
    Sampaio, F. A.
    Conti, P. C. R.
    Bonjardim, L. R.
    JOURNAL OF ORAL REHABILITATION, 2017, 44 (03) : 197 - 204
  • [8] Replicate effects and test-retest reliability of quantitative sensory threshold testing in dogs with and without chronic pain
    Knazovicky, David
    Helgeson, Erika S.
    Case, Beth
    Thomson, Andrea
    Gruen, Margaret E.
    Maixner, William
    Lascelles, B. Duncan X.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2017, 44 (03) : 615 - 624
  • [9] Test-retest reliability of a simple bedside-quantitative sensory testing battery for chronic neuropathic pain
    Sachau, Juliane
    Appel, Christina
    Reimer, Maren
    Sendel, Manon
    Vollert, Jan
    Huellemann, Philipp
    Baron, Ralf
    PAIN REPORTS, 2023, 8 (01) : E1049
  • [10] Hop testing symmetry improves with time and while wearing a functional knee brace in anterior cruciate ligament reconstructed athletes
    Peebles, Alexander T.
    Miller, Thomas K.
    Moskal, Joseph T.
    Queen, Robin M.
    CLINICAL BIOMECHANICS, 2019, 70 : 66 - 71