Controlling Legionella pneumophila growth in hot water systems by reducing dissolved oxygen levels

被引:0
|
作者
Krause, J. David [1 ,2 ]
机构
[1] Healthcare Consulting & Contracting, Tallahassee, FL 32309 USA
[2] Healthcare Consulting & Contracting, 2976 Wellington Circle West, Tallahassee, FL 32309 USA
关键词
Legionellosis; Legionnaires' disease; healthcare hot water systems; waterborne pathogen control; LEGIONNAIRES-DISEASE; CULTURE;
D O I
10.1080/15459624.2024.2313580
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Legionella pneumophila, the leading cause of Legionnaires' disease in the United States, is found in lakes, ponds, and streams but poses a health risk when it grows in building water systems. The growth of L. pneumophila in hot water systems of healthcare facilities poses a significant risk to patients, staff, and visitors. Hospitals and long-term care facilities account for 76% of reported Legionnaires' disease cases with mortality rates of 25%. Controlling L. pneumophila growth in hot water systems serving healthcare and hospitality buildings is currently achieved primarily by adding oxidizing chemical disinfectants. Chemical oxidants generate disinfection byproducts and can accelerate corrosion of premise plumbing materials and equipment. Alternative control methods that do not generate hazardous disinfection byproducts or accelerate corrosion are needed. L. pneumophila is an obligate aerobe that cannot sustain cellular respiration, amplify, or remain culturable when dissolved oxygen (DO) concentrations are too low (< 0.3 mg/L). An alternative method of controlling L. pneumophila growth by reducing DO levels in a hot water model system using a gas transfer membrane contactor was evaluated. A hot water model system was constructed and inoculated with L. pneumophila at DO concentrations above 0.5 mg/L. Once the model system was colonized, DO levels were incrementally reduced. Water samples were collected each week to evaluate the effect of reducing dissolved oxygen levels when all other conditions favored Legionella amplification. At DO concentrations below 0.3 mg/L, L. pneumophila concentrations were reduced by 1-log over 7 days. Under conditions in the hot water model system, at favorable temperatures and with no residual chlorine disinfectant, L. pneumophila concentrations were reduced by 1-log, indicating growth inhibition by reducing DO levels as the sole control measure. In sections of the model system where DO levels were not lowered L. pneumophila continued to grow. Reducing dissolved oxygen levels in hot water systems of healthcare and other large buildings to control L. pneumophila could also lower the risk of supplemental chemical treatment methods currently in use.
引用
收藏
页码:259 / 269
页数:11
相关论文
共 50 条
  • [1] Controlling Legionella pneumophila in water systems at reduced hot water temperatures with copper and silver ionization
    Cloutman-Green, Elaine
    Barbosa, Vera L.
    Jimenez, Diego
    Wong, Daniel
    Dunn, Helen
    Needham, Brian
    Ciric, Lena
    Hartley, John C.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2019, 47 (07) : 761 - 766
  • [2] Environmental surveillance of Legionella pneumophila in hot water systems of hotels in Morocco
    Assaidi, Abdelwahid
    Soummane, Afaf
    Ellouali, Mostafa
    Latrache, Hassan
    Timinouni, Mohammed
    Zahir, Hafida
    Mliji, El Mostafa
    JOURNAL OF WATER AND HEALTH, 2021, 19 (05) : 855 - 863
  • [3] LEGIONELLA PNEUMOPHILA IN HOSPITAL HOT WATER CYLINDERS
    FISHERHOCH, SP
    SMITH, MG
    COLBOURNE, JS
    LANCET, 1982, 1 (8280): : 1073 - 1073
  • [4] CORRELATION BETWEEN GROWTH OF LEGIONELLA PNEUMOPHILA AND IRON CONTENT IN HOT WATER-SYSTEMS AND CULTURE MEDIA
    HAHN, T
    TOUGIANIDOU, D
    BOTZENHART, K
    ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIE B-UMWELTHYGIENE KRANKENHAUSHYGIENE ARBEITSHYGIENE PRAVENTIVE MEDIZIN, 1987, 184 (05): : 425 - 425
  • [5] Managing Legionella pneumophila in Water Systems
    LeChevallier, Mark W.
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2020, 112 (02): : 11 - 23
  • [6] LEGIONELLA PNEUMOPHILA AND WATER-SYSTEMS
    GORDON, H
    BRITISH MEDICAL JOURNAL, 1981, 282 (6268): : 988 - 988
  • [7] LEGIONELLA PNEUMOPHILA IN WATER PLUMBING SYSTEMS
    DENNIS, PJ
    TAYLOR, JA
    FITZGEORGE, RB
    BARTLETT, CLR
    BARROW, GI
    LANCET, 1982, 1 (8278): : 949 - 951
  • [8] INFLUENCE OF TEMPERATURE ON THE NUMBER OF LEGIONELLA-PNEUMOPHILA IN HOT WATER-SYSTEMS
    GROOTHUIS, DG
    VEENENDAAL, HR
    DIJKSTRA, HL
    JOURNAL OF APPLIED BACTERIOLOGY, 1985, 59 (06): : 529 - 536
  • [9] Convective Mixing in Distal Pipes Exacerbates Legionella pneumophila Growth in Hot Water Plumbing
    Rhoads, William J.
    Pruden, Amy
    Edwards, Marc A.
    PATHOGENS, 2016, 5 (01):
  • [10] Investigation of Legionella pneumophila and free living amoebas in the domestic hot water systems in Istanbul