Characterizing continuous positive airway pressure (CPAP) Belly Syndrome in preterm infants in the neonatal intensive care unit (NICU)

被引:0
|
作者
Gu, Hannah [1 ]
Seekins, Jayne [2 ]
Ritter, Victor [3 ]
Halamek, Louis P. [1 ]
Wall, James K. [4 ]
Fuerch, Janene H. [1 ]
机构
[1] Stanford Univ, Div Neonatol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Pediat Radiol, Stanford, CA USA
[3] Stanford Univ, Quantitat Sci Unit, Stanford, CA USA
[4] Stanford Univ, Dept Pediat Gen Surg, Stanford, CA USA
关键词
BIRTH-WEIGHT INFANTS; VENTILATION; INTUBATION; BOWEL;
D O I
10.1038/s41372-024-01918-2
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: Reproducibly define CPAP Belly Syndrome (CBS) in preterm infants and describe associated demographics, mechanical factors, and outcomes. Study design: A retrospective case-control study was conducted in infants <32 weeks gestation in the Stanford Children's NICU from January 1, 2020 to December 31, 2021. CBS was radiographically defined by a pediatric radiologist. Data analysis included descriptive statistics and comparator tests. Results: Analysis included 41 infants with CBS and 69 infants without. CBS was associated with younger gestational age (median 27.7 vs 30 weeks, p < 0.001) and lower birthweight (median 1.00 vs 1.31 kg, p < 0.001). Infants with CBS were more likely to receive bilevel respiratory support and higher positive end expiratory pressure. Infants with CBS took longer to advance enteral feeds (median 10 vs 7 days, p = 0.003) and were exposed to more abdominal radiographs. Conclusions: Future CBS therapies should target small infants, prevent air entry from above, and aim to reduce time to full enteral feeds and radiographic exposure.
引用
收藏
页码:1269 / 1275
页数:7
相关论文
共 50 条
  • [1] A trial comparing continuous positive airway pressure (CPAP) devices in preterm infants
    Backes, Carl H.
    Cooper, Jennifer N.
    Notestine, Jennifer L.
    Alfred, Crystal M.
    Ball, Molly K.
    Rivera, Brian K.
    Lamp, Jane M.
    Marzec, Laura
    Stenger, Michael R.
    Moallem, Mohannad
    Miller, Randy R.
    Naik, Apurwa
    Beer, Lindsey J.
    Howard, Christopher R.
    Welty, Stephen E.
    Richardson, C. Peter
    Hillman, Noah H.
    Zupancic, John A. F.
    Stanberry, Larissa, I
    Hansen, Thomas N.
    Smith, Charles, V
    JOURNAL OF PERINATOLOGY, 2020, 40 (08) : 1193 - 1201
  • [2] A trial comparing continuous positive airway pressure (CPAP) devices in preterm infants
    Carl H. Backes
    Jennifer N. Cooper
    Jennifer L. Notestine
    Crystal M. Alfred
    Molly K. Ball
    Brian K. Rivera
    Jane M. Lamp
    Laura Marzec
    Michael R. Stenger
    Mohannad Moallem
    Randy R. Miller
    Apurwa Naik
    Lindsey J. Beer
    Christopher R. Howard
    Stephen E. Welty
    C. Peter Richardson
    Noah H. Hillman
    John A. F. Zupancic
    Larissa I. Stanberry
    Thomas N. Hansen
    Charles V. Smith
    Journal of Perinatology, 2020, 40 : 1193 - 1201
  • [3] Neonatal helmet-continuous positive airway pressure in preterm infants
    Trevisanuto, D.
    Doglioni, N.
    Grazzina, N.
    ANAESTHESIA, PAIN, INTENSIVE CARE AND EMERGENCY MEDICINE, 2005, : 787 - 793
  • [4] Prophylactic or very early initiation of continuous positive airway pressure (CPAP) for preterm infants
    Subramaniam, Prema
    Ho, Jacqueline J.
    Davis, Peter G.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2021, (10):
  • [5] Quality Improvement of Nasal Continuous Positive Airway Pressure Therapy in Neonatal Intensive Care Unit
    Chen, Chien-Yi
    Chou, An-Kuo
    Chen, Yu-Lien
    Chou, Hung-Chieh
    Tsao, Po-Nien
    Hsieh, Wu-Shiun
    PEDIATRICS AND NEONATOLOGY, 2017, 58 (03): : 229 - 235
  • [6] Care of Preterm Infants in the Neonatal Intensive Care Unit
    Hack, Maureen
    PEDIATRICS, 2009, 123 (04) : 1246 - 1247
  • [7] A new device for administration of continuous positive airway pressure in preterm infants: comparison with a standard nasal CPAP continuous positive airway pressure system
    Trevisanuto, D
    Grazzina, N
    Doglioni, N
    Ferrarese, P
    Marzari, F
    Zanardo, V
    INTENSIVE CARE MEDICINE, 2005, 31 (06) : 859 - 864
  • [8] A new device for administration of continuous positive airway pressure in preterm infants: comparison with a standard nasal CPAP continuous positive airway pressure system
    Daniele Trevisanuto
    Nicoletta Grazzina
    Nicoletta Doglioni
    Paola Ferrarese
    Francesco Marzari
    Vincenzo Zanardo
    Intensive Care Medicine, 2005, 31 : 859 - 864
  • [9] Increased Forced Expiratory Flows in Former Preterm Infants Randomized to Two Extra Weeks of Continuous Positive Airway Pressure (CPAP) in the NICU
    Mcevoy, C. T.
    Macdonald, K. D.
    Go, M.
    Milner, K.
    Harris, J.
    Schilling, D.
    Olson, M.
    Tiller, C.
    Slaven, J.
    Bjerregaard, J.
    Vu, A.
    Martin, A.
    Mamidi, R.
    Schelonka, R.
    Morris, C.
    Tepper, R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [10] Early enteral feeding protocols eor preterm infants in the neonatal intensive care unit (NICU).
    Szabo, IS
    Clark, MD
    JOURNAL OF INVESTIGATIVE MEDICINE, 1996, 44 (01) : A59 - A59