Influence of filler types on wear and surface hardness of composite resin restorations

被引:3
|
作者
Chen, Fei [1 ]
Sun, Lijuan [2 ]
Luo, Hao [3 ,4 ]
Yu, Peng [3 ,4 ]
Lin, Jiang [1 ,5 ]
机构
[1] Capital Med Univ, Beijing Tongren Hosp, Dept Stomatol, Beijing, Peoples R China
[2] Inner Mongolia Med Univ, Ordos Cent Hosp, Dept Stomatol, Hohhot, Inner Mongolia, Peoples R China
[3] Inner Mongolia Med Univ, Ordos Sch Clin Med, Hohhot, Inner Mongolia, Peoples R China
[4] Peking Univ, Sch & Hosp Stomatol, Dept Cariol & Endodontol, Beijing, Peoples R China
[5] Capital Med Univ, Beijing Tongren Hosp, Dept Stomatol, 1, Dongjiaomingxiang Ave, Beijing 100730, Peoples R China
关键词
Filler type; abrasive wear; hardness; surface morphology; 2-BODY WEAR; ROUGHNESS; BEHAVIOR; NANOFILLER; RESISTANCE;
D O I
10.1177/22808000231193524
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective:Wear and surface hardness of resin composites are of relevance from the clinical standpoint. With the incorporation of novel filler system, more studies need to be performed to investigate newly marketed resin composites. The objective of this study was to investigate the abrasive wear and surface hardness of dental restorative with different filler types.Methods:Nanohybrid filled Harmonize (HM) and Tetric N-Ceram (TNC), microhybrid filled Filtek Z250 (Z250), nanofilled Filtek Z350 (Z350) were included in the study. Twelve cylindrical resin composites specimens with 10 mm in diameter and 6 mm in thickness were prepared for abrasive wear test. Eight hundred cycles under 17 kg load were conducted for final wear by CW3-1 wear machine. The specimen was cleaned with an ultrasonic unit for 3 min followed with drying procedure. After measurement of weight loss and the density of specimens, the specimens were kept for measurement of surface hardness. Surface hardness was measured using a micro-hardness tester with a Vickers diamond indenter after polishing. Three specimens of each material were observed by scanning electron microscopy (SEM) after the abrasion to evaluate the morphology of the surface. Data were analyzed using one-way analysis of variance (ANOVA), followed by Tukey HSD test (alpha = .05).Results:Z250 performed the least volume wear loss (41.1 +/- 2.1 mm3), as well as the hardest value (102.7 +/- 2.9 HV). There was no significant difference with the volume wear loss (p = 1.000) and surface hardness (p = 0.874) of HM and TNC. SEM images of nanohybrid filled HM and TNC represented smoother surface compared with other types of resin composites.Conclusions:Microhybrid Z250 showed the highest wear resistance and surface hardness, nanofilled and nanohybrid resin composites may still face the insufficient of wear and surface hardness quality.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Influence of Surface Sealants on Microleakage of Composite Resin Restorations
    dos Santos, Paulo Henrique
    Pavan, Sabrina
    Assuncao, Wirley Concalves
    Consani, Simonides
    Correr-Sobrinho, Lourenco
    Coelho Sinhoreti, Mario Alexandre
    JOURNAL OF DENTISTRY FOR CHILDREN, 2008, 75 (01): : 24 - 28
  • [2] Influence of photoactivation method and mold for restoration on the Knoop hardness of resin composite restorations
    William Cunha Brandt
    Lais Regiane Silva-Concilio
    Ana Christina Claro Neves
    Eduardo Jose Carvalho de Souza-Junior
    Mario Alexandre Coelho Sinhoreti
    Lasers in Medical Science, 2013, 28 : 1227 - 1231
  • [3] Influence of photoactivation method and mold for restoration on the Knoop hardness of resin composite restorations
    Brandt, William Cunha
    Silva-Concilio, Lais Regiane
    Claro Neves, Ana Christina
    Carvalho de Souza-Junior, Eduardo Jose
    Coelho Sinhoreti, Mario Alexandre
    LASERS IN MEDICAL SCIENCE, 2013, 28 (05) : 1227 - 1231
  • [4] Influence of placement techniques on Vickers and Knoop hardness of class II composite resin restorations
    Poskus, LT
    Placido, E
    Cardoso, PEC
    DENTAL MATERIALS, 2004, 20 (08) : 726 - 732
  • [5] Effect of polishing techniques and time on surface roughness, hardness and microleakage of resin composite restorations
    Venturini, D
    Cenci, MS
    Demarco, FF
    Camacho, GB
    Powers, JM
    OPERATIVE DENTISTRY, 2006, 31 (01) : 11 - 17
  • [6] WEAR OF COMPOSITE RESIN RESTORATIONS IN BEVELED AND NONBEVELED PREPARATIONS
    LANG, LA
    BURGESS, JO
    LANG, BR
    WANG, RF
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 165 - 165
  • [7] Differential wear assessment of posterior composite resin restorations
    Peters, MC
    Dennison, JB
    Lang, BR
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 236 - 236
  • [8] In vitro wear of flowable resin composite for posterior restorations
    Shinkai, Koichi
    Taira, Yoshihisa
    Suzuki, Shiro
    Suzuki, Masaya
    DENTAL MATERIALS JOURNAL, 2016, 35 (01) : 37 - 44
  • [9] The influence of finishing/polishing time and cooling system on surface roughness and microhardness of two different types of composite resin restorations
    Kaminedi, Raja Rajeswari
    Penumatsa, Narendra Varma
    Priya, Tulasi
    Baroudi, Kusai
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2014, 4 (05): : 99 - 104
  • [10] The influence of hidratation on microleakage of composite resin restorations
    Russo, EMA
    Carvalho, RCR
    Pagliari, AF
    Turbino, ML
    Nauff, F
    Cardoso, MV
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 964 - 964