Motion-induced proton dose change measured by 3D deformable dosimeters in an anthropomorphic phantom

被引:0
|
作者
Jensen, S. [1 ,2 ]
Ehrbar, S. [3 ,4 ]
Worm, E. [5 ]
Muren, L. [1 ,2 ]
Tanadini-Lang, S.
Petersen, J. [5 ,6 ]
Balling, P. [7 ,8 ]
Poulsen, P. [1 ,2 ]
机构
[1] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
[2] Aarhus Univ Hosp, Danish Ctr Particle Therapy, Aarhus, Denmark
[3] Univ Zurich, Dept Radiat Oncol, Zurich, Switzerland
[4] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[5] Aarhus Univ Hosp, Dept Med Phys, Aarhus, Denmark
[6] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
[7] Aarhus Univ, Dept Phys & Astron, Aarhus, Denmark
[8] Aarhus Univ, Interdisciplinary Nanosci Ctr, Aarhus, Denmark
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
MO-0480
引用
收藏
页码:S387 / S389
页数:4
相关论文
共 50 条
  • [1] Motion-induced dose perturbations in photon radiotherapy and proton therapy measured by deformable liver-shaped 3D dosimeters in an anthropomorphic phantom
    Vindbaek, Simon
    Ehrbar, Stefanie
    Worm, Esben
    Muren, Ludvig
    Tanadini-Lang, Stephanie
    Petersen, Jorgen
    Balling, Peter
    Poulsen, Per
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 31
  • [2] Progress Toward the Development of a Deformable Anthropomorphic 3D Dosimetric Phantom
    Juang, T.
    Das, S.
    Adamovics, J.
    Oldham, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [3] Development of deformable 3D anthropomorphic dosimetry systems for proton therapy
    Jensen, S.
    Erichsen, T.
    Jensen, M.
    Balling, P.
    Petersen, J.
    Poulsen, P.
    Muren, L.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1354 - S1356
  • [4] Deformable Anthropomorphic Abdominal Phantom for the Validation of Deformable Dose Accumulation Algorithms and Intrafractional Motion Management Systems
    Matrosic, C.
    Marsh, I.
    Palmer, B.
    Hull, J.
    Bednarz, B.
    Culberson, W.
    MEDICAL PHYSICS, 2018, 45 (06) : E662 - E662
  • [5] Proton therapy dose distributions around cardiac implant leads measured with 3D dosimeters and films
    Valdetaro, L.
    Stick, L. Bjerregaard
    Sitarz, M. Krzysztof
    Muren, L. Paul
    Balling, P.
    Skyt, P. Sandegaard
    Petersen, J. Breede Baltzer
    Jensen, M. Fulgsang
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1353 - S1354
  • [6] 3D Proton Dose Distributions in an Anthropomorphic Lung Phantom, Comparing Monte Carlo, Film, and TLD Measurements
    Perles, L. A.
    Ibbott, G. S.
    Blatnica, A.
    Mirkovic, D.
    Titt, U.
    Gillin, M.
    Mohan, R.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [7] Use of Small 3D Radiochromic Dosimeters and a Motion Phantom for Dose Verification of Dynamic MLC Tracking Radiotherapy
    Costa, F.
    Menten, M.
    Doran, S.
    Adamovics, J.
    Hanson, I.
    Nill, S.
    Oelfke, U.
    MEDICAL PHYSICS, 2018, 45 (06) : E142 - E142
  • [8] Dose verification of dynamic MLC-tracked radiotherapy using small PRESAGE® 3D dosimeters and a motion phantom
    Costa, Filipa
    Menten, Martin J.
    Doran, Simon
    Adamovics, John
    Hanson, Ian M.
    Nill, Simeon
    Oelfke, Uwe
    10TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2019, 1305
  • [9] MOTION-INDUCED MONTE CARLO DOSE CALCULATION USING DEFORMABLE TETRAHEDRAL MESHES
    Touileb, Yazid
    Manescu, Petru
    Ladjal, Hamid
    Azencot, Joseph
    Beuve, Michael
    Shariat, Behzad
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 1257 - 1260
  • [10] Investigation of 3D dosimetry for an anthropomorphic spine phantom
    Grant, R.
    Ibbott, G.
    Yang, J.
    Adamovics, J.
    Followill, D.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444