A 19-color single-tube full spectrum flow cytometry assay for the detection of measurable residual disease in acute myeloid leukemia

被引:2
|
作者
Fokken, Hendrik [1 ]
Waclawski, Julian [1 ]
Kattre, Nadine [1 ]
Kloos, Arnold [1 ]
Mueller, Sebastian [2 ,3 ,4 ]
Ettinger, Max [5 ]
Kacprowski, Tim [2 ,3 ,4 ]
Heuser, Michael [1 ]
Maetzig, Tobias [6 ,7 ]
Schwarzer, Adrian [1 ,7 ,8 ,9 ,10 ]
机构
[1] Hannover Med Sch, Dept Hematol Hemostasis Oncol & Stem Cell Transpla, Hannover, Germany
[2] TU Braunschweig, Peter L Reichertz Inst Med Informat, Div Data Sci Biomed, Braunschweig, Germany
[3] Hannover Med Sch, Braunschweig, Germany
[4] TU Braunschweig, Braunschweig Integrated Ctr Syst Biol BRICS, Braunschweig, Germany
[5] Hannover Med Sch, Dept Orthoped Surg, Hannover, Germany
[6] Hannover Med Sch, Dept Pediat Hematol, Hannover, Germany
[7] Hannover Med Sch, Inst Expt Hematol, Hannover, Germany
[8] Univ Med Greifswald, CCC MV, Greifswald, Germany
[9] Univ Med Greifswald, Dept Internal Med C, Greifswald, Germany
[10] Univ Med Greifswald, Dept Internal Med C, Sauerbruchstr 1, D-17475 Greifswald, Germany
关键词
acute myeloid leukemia; full spectrum flow cytometry; measurable residual disease; Flow-MRD; PROGNOSTIC IMPACT; AML; MRD;
D O I
10.1002/cyto.a.24811
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Multiparameter flow cytometry (MFC) has emerged as a standard method for quantifying measurable residual disease (MRD) in acute myeloid leukemia. However, the limited number of available channels on conventional flow cytometers requires the division of a diagnostic sample into several tubes, restricting the number of cells and the complexity of immunophenotypes that can be analyzed. Full spectrum flow cytometers overcome this limitation by enabling the simultaneous use of up to 40 fluorescent markers. Here, we used this approach to develop a good laboratory practice-conform single-tube 19-color MRD detection assay that complies with recommendations of the European LeukemiaNet Flow-MRD Working Party. We based our assay on clinically-validated antibody clones and evaluated its performance on an IVD-certified full spectrum flow cytometer. We measured MRD and normal bone marrow samples and compared the MRD data to a widely used reference MRD-MFC panel generating highly concordant results. Using our newly developed single-tube panel, we established reference values in healthy bone marrow for 28 consensus leukemia-associated immunophenotypes and introduced a semi-automated dimensionality-reduction, clustering and cell type identification approach that aids the unbiased detection of aberrant cells. In summary, we provide a comprehensive full spectrum MRD-MFC workflow with the potential for rapid implementation for routine diagnostics due to reduced cell requirements and ease of data analysis with increased reproducibility in comparison to conventional FlowMRD routines.
引用
收藏
页码:181 / 195
页数:15
相关论文
共 50 条
  • [1] Development of a 29-Color Single-Tube Full Spectrum Flow Cytometry Assay for the Detection of Measurable Residual Disease and Leukemic Stem Cells in AML
    Zhang, Zhong
    Wilhelm, Miriam
    Sieber, Ines
    Doehner, Hartmut
    Feuring, Michaela
    BLOOD, 2024, 144 : 4331 - 4332
  • [2] Validation of a 12-color flow cytometry assay for acute myeloid leukemia minimal/measurable residual disease detection
    Wang, Sa A.
    Jorgensen, Jeffrey L.
    Hu, Shimin
    Jia, Fuli
    Li, Shaoying
    Loghavi, Sanam
    Ok, Chi Young
    Thakral, Beenu
    Xu, Jie
    Medeiros, L. Jeffrey
    Wang, Wei
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2023, 104 (05) : 356 - 366
  • [3] Reproducibility of measurable residual disease detection by flow cytometry in acute myeloid leukemia
    Roehnert, M. A.
    Kramer, M.
    Schadt, J.
    Ensel, P.
    Thiede, C.
    Krause, S.
    Buecklein, V
    Hoffmann, J.
    Jaramillo, S.
    Schlenk, R.
    Roellig, C.
    Bornhaeuser, M.
    McCarthy, N.
    Freeman, S.
    Oelschlaegel, U.
    von Bonin, M.
    ONCOLOGY RESEARCH AND TREATMENT, 2022, 45 (SUPPL 2) : 278 - 278
  • [4] Reproducible measurable residual disease detection by multiparametric flow cytometry in acute myeloid leukemia
    Roehnert, Maximilian A.
    Kramer, Michael
    Schadt, Jonas
    Ensel, Philipp
    Thiede, Christian
    Krause, Stefan W.
    Buecklein, Veit
    Hoffmann, Joerg
    Jaramillo, Sonia
    Schlenk, Richard F.
    Roellig, Christoph
    Bornhaeuser, Martin
    McCarthy, Nicholas
    Freeman, Sylvie
    Oelschlaegel, Uta
    von Bonin, Malte
    LEUKEMIA, 2022, 36 (09) : 2208 - 2217
  • [5] Reproducible measurable residual disease detection by multiparametric flow cytometry in acute myeloid leukemia
    Maximilian A. Röhnert
    Michael Kramer
    Jonas Schadt
    Philipp Ensel
    Christian Thiede
    Stefan W. Krause
    Veit Bücklein
    Jörg Hoffmann
    Sonia Jaramillo
    Richard F. Schlenk
    Christoph Röllig
    Martin Bornhäuser
    Nicholas McCarthy
    Sylvie Freeman
    Uta Oelschlägel
    Malte von Bonin
    Leukemia, 2022, 36 : 2208 - 2217
  • [6] Twenty-four-color full spectrum flow cytometry panel for minimal residual disease detection in acute myeloid leukemia
    Chen, Man
    Fu, Minjing
    Gong, Meiwei
    Gao, Yajing
    Wang, Aixian
    Zhao, Wei
    Wu, Xueying
    Wang, Hui
    OPEN MEDICINE, 2023, 18 (01):
  • [7] Analytical assay validation for acute myeloid leukemia measurable residual disease assessment by multiparametric flow cytometry
    Tettero, Jesse M.
    Dakappagari, Naveen
    Heidinga, Maaike E.
    Oussoren-Brockhoff, Yvonne
    Hanekamp, Diana
    Pahuja, Anil
    Burns, Kerri
    Kaur, Pavinder
    Alfonso, Zeni
    van Der Velden, Vincent H. J.
    te Marvelde, Jeroen G.
    Hobo, Willemijn
    Slomp, Jennichjen
    Bachas, Costa
    Kelder, Angele
    Nguyen, Kevin
    Cloos, Jacqueline
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2023, 104 (06) : 426 - 439
  • [8] 28-color single tube for flow cytometric assessment of myeloid maturation, myeloid neoplasia, and acute myeloid leukemia minimal/measurable residual disease
    Gao, Qi
    Chan, Alexander
    Zhang, Jingping
    Sun, Xiaotian
    Burke, Amanda
    Miu, Olivia
    Nguyen, Nghia
    Zhang, Shu Jie
    Reminick, Jennifer
    Wardrope, Jessica
    Roshal, Mikhail
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2025,
  • [9] A Single-Tube Seven-Colour Flow Cytometry Assay for Detection of Minimal Residual Disease In Myeloma.
    Wuilleme, Soraya
    Robillard, Nelly
    Richebourg, Steven
    Eveillard, Marion
    Lode, Laurence
    Avet-Loiseau, Herve
    BLOOD, 2010, 116 (21) : 708 - 708
  • [10] A single-tube six-colour flow cytometry screening assay for the detection of minimal residual disease in myeloma
    de Tute, R. M.
    Jack, A. S.
    Child, J. A.
    Morgan, G. J.
    Owen, R. G.
    Rawstron, A. C.
    LEUKEMIA, 2007, 21 (09) : 2046 - U2