Experimental performance assessment of a novel insulation plaster as an energy-efficient retrofit solution for external walls: A key building material towards low/zero carbon buildings

被引:30
|
作者
Cuce, Erdem [1 ,2 ,3 ]
Cuce, Pinar Mert [2 ,4 ,5 ]
Alvur, Emre [1 ,2 ]
Yilmaz, Yusuf Nadir [1 ,2 ]
Saboor, Shaik [6 ]
Ustabas, Ilker [7 ]
Linul, Emanoil [8 ]
Asif, Mohammad [9 ]
机构
[1] Recep Tayyip Erdogan Univ, Fac Engn & Architecture, Dept Mech Engn, Zihni Derin Campus, TR-53100 Rize, Turkiye
[2] Recep Tayyip Erdogan Univ, Fac Engn & Architecture, Low Zero Carbon Energy Technol Lab, Zihni Derin Campus, TR-53100 Rize, Turkiye
[3] Birmingham City Univ, Sch Engn & Built Environm, Birmingham B4 7XG, England
[4] Recep Tayyip Erdogan Univ, Fac Engn & Architecture, Dept Architecture, Zihni Derin Campus, TR-53100 Rize, Turkiye
[5] Univ Nottingham, Fac Engn, Dept Architecture & Built Environm, Nottingham NG7 2RD, England
[6] Vellore Inst Technol, Sch Mech Engn, Dept Thermal & Energy Engn, VIT, Vellore 632014, Tamil Nadu, India
[7] Recep Tayyip Erdogan Univ, Fac Engn & Architecture, Dept Civil Engn, Zihni Derin Campus, TR-53100 Rize, Turkiye
[8] Politehn Univ Timisoara, Dept Mech & Strength Mat, 1 Mihai Viteazu Ave, Timisoara 300222, Romania
[9] King Saud Univ, Dept Chem Engn, POB 800, Riyadh 11421, Saudi Arabia
关键词
Thermal insulation plaster; External wall insulation; Energy-efficient retrofit; Co-heating test; U-value; THERMAL INSULATION; WINDOW TECHNOLOGY; CONDUCTIVITY; LIME; CONSUMPTION; MORTARS;
D O I
10.1016/j.csite.2023.103350
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermal insulation plasters have become the focus of attention in the building sector. Among the most important reasons for this is the high thermal energy losses of the buildings. Since conventional briquettes used in buildings allow high heat transfer, the construction industries are looking for alternative insulation ways with low cost and high thermal efficiency. The use of insulation plasters is becoming popular due to the high cost and installation of insulation materials such as Expanded Polystyrene (EPS), which is among the alternative ways. Therefore, in this study, the novel insulation plaster (NIP) developed in contrast to traditional insulation plasters is tested on conventional briquettes in different thicknesses. On considering the total heat transfer coefficient (U-value), it is understood that whilst the conventional briquette has the highest value with approximately 5.5 W/m2K, the briquette with 2-2 NIP thickness has the lowest value with a value of almost 2.86 W/m2K. As a result of the tests, the total heat transfer coefficient of the briquette with 1-1 NIP thickness is observed to have an improvement of nearly 22.5% compared to conventional briquettes, while a progress of approximately 36.4% is seen in briquettes with 2-1 NIP thickness. In addition, it is revealed that the best mitigation in the overall heat transfer coefficient is about 47.9% in briquettes with 2-2 NIP thickness. It is also figured out that NIP has additional thermal durability thanks to the dead air pores and boron minerals in its internal structure.