(Un)Reliable detection of menstrual blood in forensic casework - evaluation of the Seratec® PMB test with mock samples

被引:3
|
作者
Konrad, Helen [1 ]
Hartung, Benno [1 ]
Poetsch, Micaela [1 ]
机构
[1] Univ Hosp Essen, Inst Legal Med, Hufelandstr 55, D-45122 Essen, Germany
关键词
Rapid test; Immunochromatographic lateral flow strip test; Stain identification; Body fluids; Menstrual blood; IMMUNOCHROMATOGRAPHIC STRIP TEST; DEVELOPMENTAL VALIDATION; IDENTIFICATION;
D O I
10.1007/s00414-023-03138-3
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
The identification of the type of body fluid in crime scene evidence may be crucial, so that the efforts are high to reduce the complexity of these analyses and to minimize time and costs. Reliable immunochromatographic rapid tests for specific and sensitive identification of blood, saliva, urine and sperm secretions are already routinely used in forensic genetics. The recently introduced Seratec (R) PMB test is said to detect not only hemoglobin, but also differentiate menstrual blood from other secretions containing blood (cells) by detecting D-dimers. In our experimental set-up, menstrual blood could be reliably detected in mock forensic samples. Here, the result was independent of sample age and extraction buffer volume. It was also successfully demonstrated that all secretions without blood cells were negative for both, hemoglobin (P) and D-dimer (M). However, several blood cell-containing secretions/tissues comprising blood (injury), nasal blood, postmortem blood and wound crust also demonstrated positive results for D-dimer (M) and were therefore false positives. For blood (injury) and nasal blood, this result was reproduced for different extraction buffer volumes. The results of this study clearly demonstrate that the Seratec (R) PMB test is neither useful nor suitable for use in forensic genetics because of the great risk of false positive results which can lead to false conclusions, especially in sexual offense or violent acts.
引用
收藏
页码:781 / 786
页数:6
相关论文
共 9 条
  • [1] (Un)Reliable detection of menstrual blood in forensic casework — evaluation of the Seratec® PMB test with mock samples
    Helen Konrad
    Benno Hartung
    Micaela Poetsch
    International Journal of Legal Medicine, 2024, 138 : 781 - 786
  • [2] Practical and reliable enzyme test for the detection of Mucopolysaccharidosis IVA (Morquio Syndrome type A) in dried blood samples
    Camelier, Marli V.
    Burin, Maira G.
    De Mari, Jurema
    Vieira, Taiane A.
    Marasca, Giorgia
    Giugliani, Roberto
    CLINICA CHIMICA ACTA, 2011, 412 (19-20) : 1805 - 1808
  • [3] Multicentre evaluation of an immunological rapid test for the detection of troponin T in whole blood samples
    Collinson, PO
    Gerhardt, W
    Katus, HA
    MullerBardorff, M
    Braun, S
    Schricke, U
    Vogt, W
    Nagel, D
    Zander, M
    Leinberger, R
    Mangold, D
    Zerback, R
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1996, 34 (07): : 591 - 598
  • [4] Early detection of colorectal cancer with a blood based test; evaluation of methylated SEPT9 gene in 2272 Spanish population samples
    Herranz, A.
    Hidalgo, B.
    Leon, M.
    Pestana, E.
    Moya, A.
    Maeso, I.
    Lopez Garcia-Asenjo, J.
    Belinchon, A.
    Van der Vorst, E.
    EUROPEAN JOURNAL OF HUMAN GENETICS, 2018, 26 : 551 - 551
  • [5] Evaluation of VIKIA® HBsAg, a new immuno-chromatographic test for the qualitative detection of HBs antigen in serum, plasma and whole blood human samples
    Marcillat, S.
    Diagbouga, S.
    Chatterjee, K.
    Choudhary, M.
    Alquezar, A. S.
    JOURNAL OF CLINICAL VIROLOGY, 2006, 36 : S63 - S63
  • [6] Development and evaluation of a point-of-care test with a combination of EZ-Fast DNA extraction and real-time PCR and LAMP detection: evaluation using blood samples containing the bovine leukaemia DNA
    Yamazaki, Y.
    Thongchankaew-Seo, U.
    Nagao, K.
    Mekata, H.
    Yamazaki, W.
    LETTERS IN APPLIED MICROBIOLOGY, 2020, 71 (06) : 560 - 566
  • [7] Field evaluation of Xpert® HCV Viral Load point-of-care test for detection of hepatitis C virus infection by venipuncture-collected and finger-stick capillary whole-blood samples
    Grebely, J.
    Lamoury, F.
    Hajarizadeh, B.
    Mowat, Y.
    Marshall, A.
    Bajis, S.
    Marks, P.
    Amin, J.
    Smith, J.
    Edwards, M.
    Gorton, C.
    Ezard, N.
    Persing, D.
    Kleman, M.
    Cunningham, P.
    Catlett, B.
    Dore, G.
    Applegate, T. L.
    JOURNAL OF HEPATOLOGY, 2017, 66 (01) : S709 - S709
  • [8] Development of a highly sensitive point-of-care test for African swine fever that combines EZ-Fast DNA extraction with LAMP detection: Evaluation using naturally infected swine whole blood samples from Vietnam
    Ngan, Mai Thi
    Thi My Le, Huynh
    Ngoc Dang, Vu
    Thi Bich Ngoc, Trinh
    Phan, Le Van
    Thi Hoa, Nguyen
    Quang Lam, Truong
    Thi Lan, Nguyen
    Notsu, Kosuke
    Sekiguchi, Satoshi
    Yamazaki, Yasuko
    Yamazaki, Wataru
    VETERINARY MEDICINE AND SCIENCE, 2023, 9 (03) : 1226 - 1233
  • [9] Evaluation of GenoFlow Thrombophilia Array Test Kit in Its Detection of Mutations in Factor V Leiden (G1691A), Prothrombin G20210A, MTHFR C677T and A1298C in Blood Samples from 113 Turkish Female Patients
    Aytekin, Ebru
    Ergun, Sezen Guntekin
    Ergun, Mehmet Ali
    Percin, Ferda E.
    GENETIC TESTING AND MOLECULAR BIOMARKERS, 2014, 18 (11) : 717 - 721