Bypass control of heat exchanger network under uncertainty

被引:1
|
作者
Manchikatla, Chaitanya [1 ]
Li, Zukui [1 ]
Huang, Biao [1 ]
机构
[1] Univ Alberta, Dept Chem & Mat Engn, Edmonton, AB, Canada
来源
关键词
heat exchanger network; model predictive control; optimization under uncertainty; DESIGN; OPTIMIZATION;
D O I
10.1002/cjce.24597
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The dynamic control of the heat exchanger network is important for developing energy-efficient and safe industrial processes. In such a system, the control is achieved through the bypass stream around the heat exchanger. This work aims to track the setpoint temperature of the mixed stream by manipulating the bypass fraction of the cold stream around the heat exchanger. The implemented control is in a non-linear model predictive control (NMPC) framework. The first-principles model of a shell and a tube heat exchanger is used. The orthogonal collocation technique is used to discretize the first-principles model into the system of algebraic equations. In this work, uncertainty is also considered in the inlet temperature of the hot stream. The uncertain optimal control problem is dealt with by using a scenario tree-based approximation along with the affine policy-based method. The results show that, under different scenarios of uncertainty, the controlled variable efficiently tracks the setpoint. In comparison, considering the same scenarios of uncertainty used, the deterministic optimization approach shows significant deviation in the controlled variable from the setpoint as time passes.
引用
收藏
页码:533 / 544
页数:12
相关论文
共 50 条
  • [1] Bypass Selection for Control of Heat Exchanger Network
    Sun Lin
    Luo Xionglin
    Hou Benquan
    Bai Yujie
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2013, 21 (03) : 276 - 284
  • [2] Coordination between bypass control and economic optimization for heat exchanger network
    Sun, Lin
    Zha, Xinlang
    Luo, Xionglin
    ENERGY, 2018, 160 : 318 - 329
  • [3] Heat-Exchanger Bypass Control
    Luyben, William L.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2011, 50 (02) : 965 - 973
  • [4] Heat exchanger network bypass position determination based on complex network control theory
    Dong, Yunqing
    Wang, Zheng
    Xu, Yifan
    Yang, Yanxia
    Jia, Xiaoping
    Wang, Fang
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2019, 38 (07): : 3046 - 3055
  • [5] A Method for Flexible Heat Exchanger Network Design under Severe Operation Uncertainty
    Zheng, Kailiang
    Lou, Helen H.
    Wang, Jing
    Cheng, Fangqin
    CHEMICAL ENGINEERING & TECHNOLOGY, 2013, 36 (05) : 757 - 765
  • [6] Coordination of bypass control and economic optimisation for heat exchanger network with stream splits
    Sun L.
    Zha X.-L.
    Luo X.-L.
    Sun, Lin (sunlin@cup.edu.cn), 2017, Italian Association of Chemical Engineering - AIDIC (61): : 187 - 192
  • [7] Operation of heat exchanger networks under uncertainty
    Li, KQ
    Luo, X
    Niemeyer, B
    Li, ML
    ENERGY AND ENVIRONMENT, VOLS 1 AND 2, 2003, : 889 - 896
  • [8] On the Effectiveness of Heat-Exchanger Bypass Control
    Soave, Nicolo
    Barolo, Massimiliano
    PROCESSES, 2021, 9 (02) : 1 - 16
  • [9] On-line control of the heat exchanger network under fouling constraints
    Markowski, Mariusz
    Trzcinski, Przemyslaw
    ENERGY, 2019, 185 (521-526) : 521 - 526
  • [10] BYPASS SELECTION FOR CONTROL OF HEAT-EXCHANGER NETWORKS
    MATHISEN, KW
    SKOGESTAD, S
    WOLFF, EA
    COMPUTERS & CHEMICAL ENGINEERING, 1992, 16 : S263 - S272