Comparison of glaucomatous from non-glaucomatous optic neuropathy using Bruch's membrane opening minimum rim width optical coherence tomography measurements

被引:0
|
作者
Gosalia, Hirika [1 ]
Kumar, Karthik M. [1 ]
Karan, A. K. [2 ]
Saravanan, Veerappan R. [2 ]
Shah, Virna M. [1 ]
机构
[1] Aravind Eye Hosp, Dept Neuroophthalmol, Coimbatore, Tamil Nadu, India
[2] Aravind Eye Hosp, Dept Vitreoretinal Serv, Coimbatore, Tamil Nadu, India
关键词
Bruch's membrane opening; compressive optic neuropathy; glaucomatous optic atrophy; optic atrophy; optical coherence tomography;
D O I
10.4103/IJO.IJO_3171_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare glaucomatous from non-glaucomatous optic atrophy using optical coherence tomography (OCT) based on the measurement values of Bruch's membrane opening minimum rim width (BMO-MRW), which is a difficult task otherwise due to their varied course of disease progression, treatment protocols, and systemic association to visual impairment. Methods: This study was conducted in 40 eyes, comprising 20 eyes with non-glaucomatous optic neuropathy (NGON) and 20 eyes with glaucomatous optic neuropathy (GON). All patients underwent a complete ophthalmic examination followed by an OCT optic disc scan to calculate the measurement of BMO-MRW. Results: The 5-fold cross-validated area under the curve for GON versus NGON from logistic regression models was 0.95 (95% confidence interval [CI]: 0.86-1.00) using BMO-MRW values from all sectors. The results revealed that the measurements were significantly lesser in GON than in NGON patients. Conclusion: Hence, OCT-based BMO-MRW values could be used as an additional test to compare glaucomatous with non-glaucomatous optic neuropathy patients, especially in cases of high clinical suspicion.
引用
收藏
页码:3005 / 3009
页数:5
相关论文
共 50 条
  • [1] In Vivo Relationship of Corneal and Scleral Stiffness with Bruch's Membrane Opening Minimum Rim Width in Glaucomatous versus Non-Glaucomatous Eyes
    Madhan, Nayasha S.
    Buma, Stephen
    Ma, Yanhui
    Mahmoud, Ashraf
    Fleming, Gloria
    Roberts, Cynthia J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [2] DIFFERENTIATION OF NON-GLAUCOMATOUS FROM GLAUCOMATOUS OPTIC NEUROPATHY WITH OPTICAL COHERENCE TOMOGRAPHY AND HEIDELBERG RETINAL TOMOGRAPHY
    Danesh-Meyer, Helen
    Yap, Joel
    Frampton, Chris
    Savino, Peter
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 : 29 - 30
  • [3] Discrimination of glaucomatous from non-glaucomatous optic neuropathy with swept-source optical coherence tomography
    Fabra, Matheu
    Trecu, M. Saint-Gerons
    Quiroga, M. J. Quiroz
    de Mendiola, Armentia Perez
    de Mendiola, J. Armentia Perez
    Palmer, A. Martinez
    Baranera, M. Martin
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (08): : 941 - 948
  • [4] Reproducibility of Bruch's membrane opening-minimum rim width measurements with Spectralis optical coherence tomography
    Lee, Jiwoong
    Park, Keunheung
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [5] A comprehensive enhanced depth imaging spectral-domain optical coherence tomography analysis of pseudoexfoliation spectrum from non-glaucomatous to advanced stage glaucoma in the aspect of Bruch's membrane opening-minimum rim width
    Mustafa Hepokur
    Cansu Yuksel Elgin
    Medine Gunes
    Fatma Sali
    Halit Oguz
    International Ophthalmology, 2022, 42 : 1835 - 1847
  • [6] A comprehensive enhanced depth imaging spectral-domain optical coherence tomography analysis of pseudoexfoliation spectrum from non-glaucomatous to advanced stage glaucoma in the aspect of Bruch's membrane opening-minimum rim width
    Hepokur, Mustafa
    Elgin, Cansu Yuksel
    Gunes, Medine
    Sali, Fatma
    Oguz, Halit
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (06) : 1835 - 1847
  • [7] Reproducibility of Bruch Membrane Opening-Minimum Rim Width Measurements With Spectral Domain Optical Coherence Tomography
    Park, Keunheung
    Kim, Jinmi
    Lee, Jiwoong
    JOURNAL OF GLAUCOMA, 2017, 26 (11) : 1041 - 1050
  • [8] The minimum rim width at Bruch's membrane opening (BMO-MRW) and detection of early glaucomatous damage
    Jarukasetphon, Ravivarn
    Wang, Diane
    Zhang, Xian
    Muhammad, Hassan
    Grillo, Lola
    Ramachandran, Rithambara
    Ritch, Robert
    Hood, Donald
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [9] Differentiating Glaucomatous Optic Neuropathy From Non-glaucomatous Optic Neuropathies Using Deep Learning Algorithms
    Vali, Mahsa
    Mohammadi, Massood
    Zarei, Nasim
    Samadi, Melika
    Atapour-Abarghouei, Amir
    Supakontanasan, Wasu
    Suwan, Yanin
    Subramanian, Prem S.
    Miller, Neil R.
    Kafieh, Rahele
    Fard, Masoud Aghsaei
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 252 : 1 - 8
  • [10] Intra- and interobserver reproducibility of Bruch's membrane opening minimum rim width measurements with spectral domain optical coherence tomography
    Reis, Alexandre S. C.
    Zangalli, Camila E. S.
    Abe, Ricardo Y.
    Silva, Andre L.
    Vianna, Jayme R.
    Vasconcellos, Jose Paulo C.
    Costa, Vital P.
    ACTA OPHTHALMOLOGICA, 2017, 95 (07) : E548 - E555