Multimodal and multiscale characterization reveals how tendon structure and mechanical response are altered by re duce d loading

被引:7
|
作者
Pierantoni, Maria [1 ,6 ]
Barreto, Isabella Silva [1 ]
Hammerman, Malin [1 ,2 ]
Novak, Vladimir [3 ]
Diaz, Ana [3 ]
Engqvist, Jonas [4 ]
Eliasson, Pernilla [2 ,5 ]
Isaksson, Hanna [1 ]
机构
[1] Lund Univ, Dept Biomed Engn, Box 118, S-22100 Lund, Sweden
[2] Linkoping Univ, Dept Biomed & Clin Sci, S-58183 Linkoping, Sweden
[3] Paul Scherrer Inst 5232, CH-5232 Villigen, Switzerland
[4] Lund Univ, Dept Solid Mech, Box 118, S-22100 Lund, Sweden
[5] Sahlgrens Univ Hosp, Dept Orthopaed, Gothenburg, Sweden
[6] Lund Univ, Dept Biomed Engn, LTH, Box 118, S-22100 Lund, Sweden
基金
欧洲研究理事会; 瑞典研究理事会;
关键词
Collagen fibers; Mechanobiology; Synchrotron imaging; Scattering; Tomography; 3D orientations; ACHILLES-TENDON; PATELLAR TENDON; VISCOELASTIC PROPERTIES; COLLAGEN; ELASTIN; MECHANOBIOLOGY; MUSCLE; DAMAGE; MICROSTRUCTURE; DEFORMATION;
D O I
10.1016/j.actbio.2023.07.021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tendons are collagen-based connective tissues where the composition, structure and mechanics respond and adapt to the local mechanical environment. Adaptation to prolonged inactivity can result in stiffer tendons that are more prone to injury. However, the complex relation between reduced loading, structure, and mechanical performance is still not fully understood. This study combines mechanical testing with high-resolution synchrotron X-ray imaging, scattering techniques and histology to elucidate how reduced loading affects the structural properties and mechanical response of rat Achilles tendons on multiple length scales. The results show that reduced in vivo loading leads to more crimped and less organized fibers and this structural inhomogeneity could be the reason for the altered mechanical response. Unloading also seems to change the fibril response, possibly by altering the strain partitioning between hierarchical levels, and to reduce cell density. This study elucidates the relation between in vivo loading, the Achilles tendon nano-, meso-structure and mechanical response. The results provide fundamental insights into the mechanoregulatory mechanisms guiding the intricate biomechanics, tissue structural organization, and performance of complex collagen-based tissues.Statement of significance Achilles tendon properties allow a dynamic interaction between muscles and tendon and influence force transmission during locomotion. Lack of physiological loading can have dramatic effects on tendon structure and mechanical properties. We have combined the use of cutting-edge high-resolution synchrotron techniques with mechanical testing to show how reduced loading affects the tendon on multiple hierarchical levels (from nanoscale up to whole organ) clarifying the relation between structural changes and mechanical performance. Our findings set the first step to address a significant healthcare challenge, such as the design of tailored rehabilitations that take into consideration structural changes after tendon immobilization.& COPY; 2023 The Author(s). Published by Elsevier Ltd on behalf of Acta Materialia Inc. This is an open access article under the CC BY license ( http://creativecommons.org/licenses/by/4.0/ )
引用
收藏
页码:264 / 276
页数:13
相关论文
共 7 条
  • [1] Micro- and nanostructure specific X-ray tomography reveals less matrix formation and altered collagen organization following re duce d loading during Achilles tendon healing
    Barreto, Isabella Silva
    Pierantoni, Maria
    Nielsen, Leonard C.
    Hammerman, Malin
    Diaz, Ana
    Novak, Vladimir
    Eliasson, Pernilla
    Liebi, Marianne
    Isaksson, Hanna
    ACTA BIOMATERIALIA, 2024, 174 : 245 - 257
  • [2] Tendon healing affects the multiscale mechanical, structural and compositional response of tendon to quasi-static tensile loading
    Freedman, Benjamin R.
    Rodriguez, Ashley B.
    Hillin, Cody D.
    Weiss, Stephanie N.
    Han, Biao
    Han, Lin
    Soslowsky, Louis J.
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2018, 15 (139)
  • [3] Cranial suture morphometry and mechanical response to loading: 2D vs. 3D assumptions and characterization
    Ross Remesz
    Tsolmonbaatar Khurelbaatar
    Miranda Grotski
    Tracy Popowics
    Katherine Rafferty
    Susan W. Herring
    Owen Addison
    Michael R. Doschak
    Dan L. Romanyk
    Biomechanics and Modeling in Mechanobiology, 2022, 21 : 1251 - 1265
  • [4] Cranial suture morphometry and mechanical response to loading: 2D vs. 3D assumptions and characterization
    Remesz, Ross
    Khurelbaatar, Tsolmonbaatar
    Grotski, Miranda
    Popowics, Tracy
    Rafferty, Katherine
    Herring, Susan W.
    Addison, Owen
    Doschak, Michael R.
    Romanyk, Dan L.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2022, 21 (04) : 1251 - 1265
  • [5] Sputter-Deposited Mo Thin Films: Multimodal Characterization of Structure, Surface Morphology, Density, Residual Stress, Electrical Resistivity, and Mechanical Response
    Kalaswad, M.
    Custer, J. O.
    Addamane, S.
    Khan, R. M.
    Jauregui, L.
    Babuska, T. F.
    Henriksen, A.
    DelRio, F. W.
    Dingreville, R.
    Boyce, B. L.
    Adams, D. P.
    INTEGRATING MATERIALS AND MANUFACTURING INNOVATION, 2023, 12 (02) : 118 - 129
  • [6] Sputter-Deposited Mo Thin Films: Multimodal Characterization of Structure, Surface Morphology, Density, Residual Stress, Electrical Resistivity, and Mechanical Response
    M. Kalaswad
    J. O. Custer
    S. Addamane
    R. M. Khan
    L. Jauregui
    T. F. Babuska
    A. Henriksen
    F. W. DelRio
    R. Dingreville
    B. L. Boyce
    D. P. Adams
    Integrating Materials and Manufacturing Innovation, 2023, 12 : 118 - 129
  • [7] Application of multiple forms of mechanical loading to human osteoblasts reveals increased ATP release in response to fluid flow in 3D cultures and differential regulation of immediate early genes
    Rumney, R. M. H.
    Sunters, A.
    Reilly, G. C.
    Gartland, A.
    JOURNAL OF BIOMECHANICS, 2012, 45 (03) : 549 - 554