Dosimetric comparison of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy for free-breathing whole-breast irradiation: A planning study

被引:2
|
作者
Czeremszynska, Beata [1 ]
Socha, Joanna [1 ,2 ]
Rygielska, Anna [1 ,3 ]
Walewska, Agnieszka [4 ]
Gabor, Marta [1 ,3 ]
Pruska-Pich, Dorota [1 ,3 ]
Osowiecka, Karolina [5 ]
Kepka, Lucyna [1 ]
机构
[1] Natl Res Inst, Mil Inst Med, Dept Radiotherapy, Warsaw, Poland
[2] Reg Oncol Ctr, Dept Radiotherapy, Czestochowa, Poland
[3] Natl Res Inst, Mil Inst Med, Lab Med Phys, Warsaw, Poland
[4] Maria Sklodowska Curie Natl Res Inst Oncol, Dept Med Phys, Warsaw, Poland
[5] Univ Warmia & Mazury, Dept Psychol & Sociol Hlth & Publ Hlth, Olsztyn, Poland
关键词
Breast neoplasms; breath holding; conformal radiotherapy; heart; intensity-modulated; radiotherapy; CANCER RADIOTHERAPY; HEART; IMRT; RISK; HOLD; 3D-CRT; LUNG; DELINEATION; EXPOSURE; VMAT;
D O I
10.4103/ijc.ijc_450_21
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Currently, recommended heart dose constraints are difficult to meet in whole-breast irradiation (WBI) for left-sided breast cancer patients, who cannot be treated with the deep inspiration breath hold. We performed a radiotherapy planning study to establish if the use of intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) allows for better sparing of the heart and its subvolumes than the three-dimensional conformal radiation therapy (3D-CRT), and how these attempts affect the dose delivered to the other organs. Methods: A total of 17 left-sided and 10 right-sided consecutive patients treated with free-breathing WBI were retrospectively included. The 3D-CRT, IMRT, and VMAT plans were generated. Several dose-volume parameters and plan quality indices were compared, separately for the left- and right-sided plans. Results: All the techniques fulfilled the planning objectives. In the left-sided plans, there was no heart or left ventricle dose reduction with IMRT, nor with VMAT; the maximum dose in the left anterior descending coronary artery was reduced with VMAT (P = 0.005); V-5 for the contralateral breast, contralateral lung, and total-body increased markedly in VMAT, and for the ipsilateral lung (V5IL) also in IMRT, compared with 3D-CRT (P < 0.001). In the right-sided plans, the V-5 values, except for V5IL, did not differ between the three techniques. Conclusions: IMRT and VMAT had a limited heart-sparing benefit in the left-sided free-breathing WBI, at the cost of increased low-dose volumes, measured by V-5. The low-dose volumes are not increased by IMRT or VMAT in the right-sided WBI, where heart sparing is not a problem, but the attempts to reduce cardiac doses in the left-sided WBI increase them.
引用
收藏
页码:258 / 265
页数:8
相关论文
共 50 条
  • [1] Comparison of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy in the treatment of cervical esophageal carcinoma
    Yang, Hao
    Feng, Cong
    Cai, Bo-Ning
    Yang, Jun
    Liu, Hai-Xia
    Ma, Lin
    DISEASES OF THE ESOPHAGUS, 2017, 30 (02):
  • [2] Comparison of Three-Dimensional Conformal Radiation Therapy, Intensity-Modulated Radiation Therapy, and Volumetric-Modulated Arc Therapy In Glioblastoma Multiforme Radiation Therapy With EORTC Target Delineation
    Ibis, Kamuran
    Akbas, Ugur
    Koksal, Canan
    Altun, Musa
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2018, 33 (02): : 65 - 72
  • [3] Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer
    Lin, Jia-Fu
    Yeh, Dah-Cherng
    Yeh, Hui-Ling
    Chang, Chen-Fa
    Lin, Jin-Ching
    MEDICAL DOSIMETRY, 2015, 40 (03) : 262 - 267
  • [4] Dosimetric analysis and comparison of volumetric-modulated arc therapy versus intensity-modulated radiation therapy for liver carcinoma
    Chiang, Bing-Hao
    Schnell, Erich
    Hibbitts, Kerry
    Herman, Terence
    Ahmad, Salahuddin
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 138 - 140
  • [5] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [6] A dosimetric comparison of three-dimensional conformal, intensity-modulated radiation therapy, and MammoSite partial-breast irradiation
    Khan, Atif J.
    Kirk, Michael C.
    Mehta, Par S.
    Seif, Neil S.
    Griem, Katherine L.
    Bernard, Damian A.
    Chu, James C. H.
    Dickler, Adam
    BRACHYTHERAPY, 2006, 5 (03) : 183 - 188
  • [7] Comparison of three-dimensional conformal radiation therapy and intensity-modulated radiation therapy systems
    Verhey, LJ
    SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) : 78 - +
  • [8] Volumetric Modulated Arc Therapy for Brain Tumors: Dosimetric Comparison with Intensity-Modulated Radiation Therapy
    Ter-Antonyan, R.
    Yang, W.
    Geesey, C.
    Lain, D.
    Larner, J.
    Benedict, S.
    MEDICAL PHYSICS, 2010, 37 (06) : 3213 - +
  • [9] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for pancreatic malignancies
    Ali, Arif N.
    Dhabaan, Anees H.
    Jarrio, Christie S.
    Siddiqi, Arsalan K.
    Landry, Jerome C.
    MEDICAL DOSIMETRY, 2012, 37 (03) : 271 - 275
  • [10] A Dosimetric Comparison of Volumetric-Modulated Arc Therapy to Intensity-Modulated Radiation Therapy in the Treatment of Locally Advanced Rectal Carcinoma
    Eldebawy E.
    Rashed Y.A.
    AlKhaldi M.
    Day E.
    Iranian Journal of Medical Physics, 2020, 17 (06) : 374 - 379