Fast Quantitative Magnetic Resonance Imaging Evaluation of Hydrocephalus Using 3-Dimensional Fluid-Attenuated Inversion Recovery: Initial Experience

被引:0
|
作者
Goo, Hyun Woo [1 ,2 ]
Park, Sang Hyub
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, 88,Olymp Ro 43 Gil, Seoul 05505, South Korea
[2] Univ Ulsan, Res Inst Radiol, Asan Med Ctr, Coll Med, 88,Olymp Ro 43 Gil, Seoul 05505, South Korea
关键词
brain ventricular system; hydrocephalus; image segmentation; magnetic resonance imaging; volume measurement; VENTRICULAR VOLUME; MRI; FLAIR;
D O I
10.1097/RCT.0000000000001539
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: This study aimed to demonstrate the initial experience of using fast quantitative magnetic resonance imaging (MRI) to evaluate hydrocephalus. Methods: A total of 109 brain MRI volumetry examinations (acquisition time, 7 minutes 30 seconds) were performed in 72 patients with hydrocephalus. From the measured ventricular system and brain volumes, ventricle-brain volume percentage was calculated to standardize hydrocephalus severity (processing time, <5 minutes). The obtained values were categorized into no, mild, and severe based on the fronto-occipital horn ratio (FOHR) and the ventricle-brain volume percentages reported in the literature. The measured volumes and percentages were compared between patients with mild hydrocephalus and those with severe hydrocephalus. The diagnostic performance of brain hydrocephalus MRI volumetry was evaluated using receiver operating characteristic curve analysis. Results: Ventricular volumes and ventricle-brain volume percentages were significantly higher in in patients with severe hydrocephalus than in those with mild hydrocephalus (FOHR-based severity: 352.6 +/- 165.6 cm(3) vs 149.1 +/- 78.5 cm(3), P < 0.001, and 26.8% [20.8%-33.1%] vs 12.1% +/- 6.0%, P < 0.001; percentage-based severity: 359.5 +/- 143.3 cm3 vs 137.0 +/- 62.9 cm(3), P < 0.001, and 26.8% [21.8%-33.1%] vs 11.3% +/- 4.2%, P < 0.001, respectively), whereas brain volumes were significantly lower in patients with severe hydrocephalus than in those with mild hydrocephalus (FOHR-based severity: 878.1 +/- 363.5 cm(3) vs 1130.1 cm(3) [912.1-1244.2 cm(3)], P = 0.006; percentage-based severity: 896.2 +/- 324.6 cm3 vs 1142.3 cm(3) [944.2-1246.6 cm(3)], P = 0.005, respectively). The ventricle-brain volume percentage was a good diagnostic parameter for evaluating the degree of hydrocephalus (area under the curve, 0.855; 95% confidence interval, 0.719-0.990; P < 0.001). Conclusions: Brain MRI volumetry can be used to evaluate hydrocephalus severity and may provide guide interpretation because of its rapid acquisition and postprocessing times.
引用
收藏
页码:292 / 297
页数:6
相关论文
共 50 条
  • [1] Magnetic resonance imaging with fluid-attenuated inversion recovery pulse sequences in MELAS syndrome
    Kimura, M
    Hasegawa, Y
    Yasuda, K
    Sejima, H
    Inoue, M
    Yamaguchi, S
    Ando, Y
    Ohno, S
    PEDIATRIC RADIOLOGY, 1997, 27 (02) : 153 - 154
  • [2] Magnetic resonance imaging with fluid-attenuated inversion recovery pulse sequences in MELAS syndrome
    Masahiko Kimura
    Yuki Hasegawa
    Kenji Yasuda
    Hitoshi Sejima
    Makoto Inoue
    Seiji Yamaguchi
    Yukinori Ando
    Shigeru Ohno
    Pediatric Radiology, 1997, 27 : 153 - 154
  • [3] Diagnostic Value of Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging for Multilocular Ameloblastoma
    Sugianto, Irfan
    Konouchi, Hironobu
    Takeshita, Yohei
    Okada, Shunsuke
    Matsubara, Risa
    Hisatomi, Miki
    Murakami, Jun
    Bamgbose, Babatunde O.
    Yanagi, Yoshinobu
    Asaumi, Junichi
    JOURNAL OF HARD TISSUE BIOLOGY, 2018, 27 (04) : 275 - 280
  • [4] Three-dimensional fluid-attenuated inversion recovery magnetic resonance imaging findings in a patient with relapsing polychondritis
    Kato, M.
    Katayama, N.
    Naganawa, S.
    Nakashima, T.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2014, 128 (02): : 192 - 194
  • [5] Three-dimensional fluid-attenuated inversion recovery magnetic resonance imaging findings in a patient with cochlear otosclerosis
    Sugiura, Makoto
    Naganawa, Shinji
    Sone, Michihiko
    Yoshida, Tadao
    Nakashima, Tsutornu
    AURIS NASUS LARYNX, 2008, 35 (02) : 269 - 272
  • [6] Fast fluid-attenuated inversion-recovery imaging: first experience with a 3D version in epilepsy
    U. C. Wieshmann
    G. J. Barker
    M. R. Symms
    P. A. Bartlett
    J. M. Stevens
    S. D. Shorvon
    Neuroradiology, 1998, 40 : 483 - 489
  • [7] Fast fluid-attenuated inversion-recovery imaging: first experience with a 3D version in epilepsy
    Wieshmann, UC
    Barker, GJ
    Symms, MR
    Bartlett, PA
    Stevens, JM
    Shorvon, SD
    NEURORADIOLOGY, 1998, 40 (08) : 483 - 489
  • [8] Deep learning method for magnetic resonance imaging fluid-attenuated inversion recovery image synthesis
    Zhou J.
    Guo H.
    Chen H.
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2023, 40 (05): : 903 - 911
  • [9] INITIAL CLINICAL-EXPERIENCE IN MR-IMAGING OF THE BRAIN WITH A FAST FLUID-ATTENUATED INVERSION-RECOVERY PULSE SEQUENCE
    RYDBERG, JN
    HAMMOND, CA
    GRIMM, RC
    ERICKSON, BJ
    JACK, CR
    HUSTON, J
    RIEDERER, SJ
    RADIOLOGY, 1994, 193 (01) : 173 - 180
  • [10] Association of audiovestibular findings with fluid-attenuated inversion recovery magnetic resonance imaging in patients with vestibular schwannoma
    Lee, Se A.
    Hong, Hyun Sook
    Lee, Jong Dae
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2024, 244