Low-voltage ride-through capability improvement of Type-3 wind turbine through active disturbance rejection feedback control-based dynamic voltage restorer

被引:1
|
作者
Boulaoutaq, El Mahfoud [1 ,5 ]
Aziz, Asma [2 ]
El Magri, Abdelmounime [3 ]
Abbou, Ahmed [4 ]
Ajaamoum, Mohamed [1 ]
Rachdy, Azeddine [1 ]
机构
[1] Ibn Zohr Univ, Higher Sch Technol Agadir, Agadir, Morocco
[2] Edith Cowan Univ, Sch Engn, Joondalup, WA, Australia
[3] Hassan II Univ Casablanca, Natl Sch Tech Educ, Casablanca, Chile
[4] Mohammed V Univ Rabat, Mohammadia Sch Engn, Rabat, Morocco
[5] Ibn Zohr Univ, Lab Engn Sci & Energy Management, ENSA, Agadir, Morocco
来源
CLEAN ENERGY | 2023年 / 7卷 / 05期
关键词
active disturbance rejection controller (ADRC); dynamic voltage restorer (DVR); low-voltage ride-through (LVRT); Type-3 wind turbines (WTs); doubly-fed induction generator (DFIG); FED INDUCTION GENERATOR; FAULT RIDE; SCHEME; LVRT;
D O I
10.1093/ce/zkad050
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Disconnections due to voltage drops in the grid cannot be permitted if wind turbines (WTs) contribute significantly to electricity production, as this increases the risk of production loss and destabilizes the grid. To mitigate the negative effects of these occurrences, WTs must be able to ride through the low-voltage conditions and inject reactive current to provide dynamic voltage support. This paper investigates the low-voltage ride-through (LVRT) capability enhancement of a Type-3 WT utilizing a dynamic voltage restorer (DVR). During the grid voltage drop, the DVR quickly injects a compensating voltage to keep the stator voltage constant. This paper proposes an active disturbance rejection control (ADRC) scheme to control the rotor-side, grid-side and DVR-side converters in a wind-DVR integrated network. The performance of the Type-3 WT with DVR topology is evaluated under various test conditions using MATLAB (R)/Simulink (R). These simulation results are also compared with the experimental results for the LVRT capability performed on a WT emulator equipped with a crowbar and direct current (DC) chopper. The simulation results demonstrate a favourable transient and steady-state response of the Type-3 wind turbine quantities defined by the LVRT codes, as well as improved reactive power support under balanced fault conditions. Under the most severe voltage drop of 95%, the stator currents, rotor currents and DC bus voltage are 1.25 pu, 1.40 pu and 1.09 U-DC, respectively, conforming to the values of the LVRT codes. DVR controlled by the ADRC technique significantly increases the LVRT capabilities of a Type-3 doubly-fed induction generator-based WT under symmetrical voltage dip events. Although setting up ADRC controllers might be challenging, the proposed method has been shown to be extremely effective in reducing all kinds of internal and external disturbances.
引用
收藏
页码:1091 / 1109
页数:19
相关论文
共 50 条
  • [1] Low Voltage Ride-Through Capability Improvement of Wind Power Generation Using Dynamic Voltage Restorer
    Hasegawa, Naohiro
    Kumano, Teruiiisa
    RECENT ADVANCES IN ENERGY AND ENVIRONMENT, 2010, : 166 - +
  • [2] Low-Voltage Ride-Through Capability for Wind Generators Based on Dynamic Voltage Restorers
    Ramirez, Dionisio
    Martinez, Sergio
    Platero, Carlos A.
    Blazquez, Francisco
    de Castro, Rosa M.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (01) : 195 - 203
  • [3] Low-voltage Ride-through Capability Characterization of Wind Farms
    Awad, A. S.
    Abdel-Rahman, M.
    Badr, M. Abdel Latif
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2012, 40 (16) : 1808 - 1819
  • [4] A novel method to improve low-voltage ride-through capability of wind turbine generators
    Cheng, Miao-miao
    Kato, Shuhei
    Shimada, Ryuichi
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2013, 8 (05) : 522 - 528
  • [5] Voltage Compensation Scheme for DFIG Wind Turbine System to Enhance Low-Voltage Ride-Through Capability
    Tan Luong Van
    Trong Huan Nguyen
    Nhut Minh Ho
    Xuan Nam Doan
    Thanh Hai Nguyen
    2019 10TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ECCE ASIA (ICPE 2019 - ECCE ASIA), 2019, : 1334 - 1338
  • [6] Low Voltage Ride-Through Capability Enhancement of a DFIG Wind Turbine Using a Dynamic Voltage Restorer with Adaptive Fuzzy PI Controller
    El Hawatt, E.
    Hamad, M. S.
    Ahmed, K. H.
    El Arabawy, I. F.
    2013 INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2013, : 1234 - 1239
  • [7] Improvement of low-voltage ride-through by coordinated pitch control and Crowbar control for DFIG wind turbine
    Ling, Yu
    Gao, Qiang
    Cai, Xu
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2013, 33 (04): : 18 - 23
  • [8] Improvement of Fault Ride-Through Capability of Grid Connected Wind Turbine Based on a Switched Reluctance Generator Using a Dynamic Voltage Restorer
    Al Ghamdi, Saeed A.
    SUSTAINABILITY, 2023, 15 (14)
  • [9] Optimizing reliability and safety of wind turbine systems through a hybrid control technique for low-voltage ride-through capability
    Khosravi, Nima
    Dowlatabadi, Masrour
    Oubelaid, Adel
    Belkhier, Youcef
    COMPUTERS & ELECTRICAL ENGINEERING, 2025, 123
  • [10] A Review of the Low-Voltage Ride-Through Capability of Wind Power Generators
    Hu, Yi-Liang
    Wu, Yuan-Kang
    Chen, Chiu-Kuo
    Wang, Chih-Hua
    Chen, Wei-Tan
    Cho, Liang-Il
    POWER AND ENERGY SYSTEMS ENGINEERING, (CPESE 2017), 2017, 141 : 378 - 382