CVD Graphene Electrode for Direct Electrochemical Detection of Double-Stranded DNA

被引:1
|
作者
Bardaoui, Afrah [1 ]
Hammami, Asma [1 ]
Elkarous, Rabiaa [1 ]
Ali Aloui, Mohamed [1 ]
Oueslati, Rania [1 ]
Messaoud, Olfa [2 ]
Santos, Diogo M. F. [3 ]
Chtourou, Radhouane [1 ]
机构
[1] Borj Cedria Sci & Technol Pk, Res & Technol Ctr Energy, Lab Nanomat & Renewable Energy Syst, BP 95, Hammam Lif 2050, Tunisia
[2] Univ Tunis El Manar, Inst Pasteur Tunis, Biomed Genom & Oncogenet Lab, Tunis 1068, Tunisia
[3] Univ Lisbon, Ctr Phys & Engn Adv Mat, Chem Engn Dept, Lab Phys Mat & Emerging Technol,Inst Super Tecni, P-1049001 Lisbon, Portugal
关键词
graphene; CVD; Raman spectroscopy; electrochemical detection; double-stranded DNA; FIELD-EFFECT TRANSISTOR; BIOSENSORS; ELECTROCATALYSIS; NANOMATERIALS; HYBRIDIZATION; SENSOR; COPPER;
D O I
10.3390/inorganics11040173
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Understanding and regulating DNA interactions with solvents and redox-active centers opens up new possibilities for improving electrochemical signals and developing adequate biosensors. This work reports the development of a modified indium tin oxide (ITO) electrode by chemical vapor deposition (CVD) of graphene for the detection of double-stranded DNA. The modified electrode shows a better electrical conductivity than ITO, as confirmed by electrochemical impedance spectroscopy (EIS), where a drastic decrease in the charge-transfer resistance, R-ct, from similar to 320 to similar to 60 omega was observed. Sequences of double-stranded genomic DNA with a different number of base pairs are evaluated through differential pulse voltammetry (DPV), using ferri/ferrocyanide ([Fe(CN)(6)](3-/4-)) as a mediator in the solution. Variations in the electrochemical response of the [Fe(CN)(6)](3-/4-) probe are observed after introducing redox inactive double-stranded DNA ions. The redox-active [Fe(CN)(6)](3-/4-) probe serves as a scaffold to bring DNA into the graphene-modified ITO electrode surface, provoking an increase in the current and a change in the potential when the number of base pairs increases. These results are confirmed by EIS, which shows a variation in the R-ct. The calibration of DPV intensity and R-ct vs. DNA base pairs (bps) number were linear in the 495-607 bps range. The proposed method could replace the nucleic acid gel electrophoresis technique to determine the presence of a DNA fragment and quantify its size.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] An electrochemical biosensor based on a graphene oxide modified pencil graphite electrode for direct detection and discrimination of double-stranded DNA sequences
    Ahmadi, Mehran
    Ahour, Fatemeh
    ANALYTICAL METHODS, 2020, 12 (37) : 4541 - 4550
  • [2] Electrochemical Oxidation of Native Double-Stranded DNA on a Graphene-Modified Glassy Carbon Electrode
    Wang, Qingxiang
    Zheng, Meixia
    Shi, Juanlan
    Gao, Feng
    Gao, Fei
    ELECTROANALYSIS, 2011, 23 (04) : 915 - 920
  • [3] Ordered mesoporous carbon modified carbon ionic liquid electrode for the electrochemical detection of double-stranded DNA
    Zhu, Zhihong
    Li, Xia
    Zeng, Yan
    Sun, Wei
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (10): : 2313 - 2317
  • [4] Direct detection of double-stranded DNA: molecular methods and applications for DNA diagnostics
    Ghosh, Indraneel
    Stains, Cliff I.
    Ooi, Aik T.
    Segal, David J.
    MOLECULAR BIOSYSTEMS, 2006, 2 (11) : 551 - 560
  • [5] Deoxyuridine triphosphates modified with tyrosine or tryptophan aromatic groups for direct electrochemical detection of double-stranded DNA
    Suprun, Elena, V
    Khmeleva, Svetlana A.
    Kutdusova, Gulnaz R.
    Duskaev, Insaf F.
    Kuznetsova, Viktoriya E.
    Lapa, Sergey A.
    Chudinov, Alexander, V
    Radko, Sergey P.
    ELECTROCHIMICA ACTA, 2020, 362
  • [6] The isothermal amplification detection of double-stranded DNA based on a double-stranded fluorescence probe
    Shi, Chao
    Shang, Fanjin
    Pan, Mei
    Liu, Sen
    Ma, Cuiping
    BIOSENSORS & BIOELECTRONICS, 2016, 80 : 54 - 58
  • [7] THE DETECTION OF INTACT DOUBLE-STRANDED DNA BY MALDI
    LECCHI, P
    PANNELL, LK
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (10) : 972 - 975
  • [8] DIRECT DOUBLE-STRANDED DNA SEQUENCING WITH BACULOVIRUS GENOMES
    WANG, HGH
    FRASER, MJ
    JOURNAL OF VIROLOGICAL METHODS, 1991, 31 (01) : 113 - 118
  • [9] Analysis of electrochemical reaction of ferrocenylnaphthalene diimide captured by double-stranded DNA during the electrochemical detection of DNA hybridization
    Komatsu, M
    Nojima, T
    Takenaka, S
    ELECTROCHEMISTRY, 2006, 74 (01) : 65 - 67
  • [10] Direct detection and discrimination of double-stranded oligonucleotide corresponding to hepatitis C virus genotype 3a using an electrochemical DNA biosensor based on peptide nucleic acid and double-stranded DNA hybridization
    Pournaghi-Azar, M. H.
    Ahour, F.
    Hejazi, M. S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (08) : 3581 - 3587