共 12 条
Fluorescence and Colorimetric Dual-Signal Aptamer Sensor Based on Aptamer-Functionalized Fe3O4 Nanoparticles Decorated with Au and Pt Nanoparticles Combined with Fluorescently Labeled Aptamer Complementary Chain-Functionalized SiO2 Nanoparticles for Detecting the Insecticide Acetamiprid
被引:6
|作者:
Dong, Sa
[1
]
Zhu, Zixin
[1
]
Shi, Qiuyun
[1
]
He, Kangli
[1
]
Wu, Jianwei
[1
]
Feng, Jianguo
[1
]
机构:
[1] Yangzhou Univ, Coll Plant Protect, Yangzhou 225009, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Acetamiprid;
Aptamers;
SiO2;
Fe3O4-Au/Pt;
Dual-signal;
MESOPOROUS SILICA;
MAGNETIC NANOPARTICLES;
PERFORMANCE;
PESTICIDES;
ADSORPTION;
D O I:
10.1021/acsanm.3c03294
中图分类号:
TB3 [工程材料学];
学科分类号:
0805 ;
080502 ;
摘要:
Acetamiprid (ACE) is a nicotinic chloride insecticide with certain genotoxicity and cytotoxicity that poses a threat to human health. Therefore, it is necessary to establish a rapid and sensitive method for the detection of ACE in agricultural products. In this study, Au and Pt nanoparticles with enzyme-catalyzing and fluorescence-quenching ability were coated on the surface of Fe3O4 nanoparticles to obtain Fe3O4-Au/Pt. Simultaneously, SiO2 nanoparticles were synthesized. Aptamer (Apt)-functionalized Fe3O4-Au/Pt (Fe3O4-Au/Pt-Apt) and fluorescently labeled aptamers with complementary chain-functionalized SiO2 (SiO2-cDNA-FAM) were used as identification probes. Based on the specific recognition of Apts to ACE, the enzymatic activity of Fe3O4-Au/Pt, and its fluorescence quenching effect, combined with magnetic separation, a fluorescence and colorimetric dual-signal aptamer sensor for ACE detection was constructed. Based on the optimal conditions, ACE in the concentration of 0.5-6 mu g/mL presents a good linear correlation with Delta F (Delta F = F - F-0, F and F-0 are fluorescence intensities in the presence or absence of ACE) and absorbance value (A). The standard curve of the fluorescence signal was Delta F = 233.68C + 34.48. R-2 = 0.9937, and the limit of detection (LOD) was 0.42 mu g/mL. The standard curve of the colorimetric signal was A = 0.0385C + 0.0486, with R-2 = 0.9966, and the LOD was 0.39 mu g/mL. The method had no cross-reaction with thiamethoxam (THI), nitenpyram (NIT), imidacloprid (IMI), and thiamethoxam (CLO). The average recoveries of ACE in actual samples (Chinese cabbage and cucumber) were 92.69%-102.54% (CV < 3.67%) and 85.59%-97.52% (CV < 3.54%) for fluorescence and colorimetric signals, respectively. The above results show that the sensor has good specificity and can be used for actual sample detection. Meanwhile, this study provides technical support for pesticide residue detection.
引用
收藏
页码:18869 / 18879
页数:11
相关论文