Intra- and Interobserver Reliability of Shear Wave Elastography in Breast Cancer Diagnosis

被引:2
|
作者
Togawa, Riku [1 ]
Pfob, Andre [1 ]
Buesch, Christopher [2 ]
Fastner, Sarah [3 ]
Gomez, Christina [3 ]
Goncalo, Manuela [4 ]
Hennigs, Andre [3 ]
Killinger, Kristina [1 ]
Nees, Juliane [1 ]
Riedel, Fabian [1 ]
Schaefgen, Benedikt [1 ]
Stieber, Anne [5 ]
Tozaki, Mitsuhiro [6 ]
Heil, Joerg [1 ,3 ]
Barr, Richard [7 ]
Golatta, Michael [1 ,3 ,8 ]
机构
[1] Heidelberg Univ Hosp, Dept Obstet & Gynecol, Univ Breast Unit, Heidelberg, Germany
[2] Heidelberg Univ, Inst Med Biometry IMBI, Heidelberg, Germany
[3] Sankt Elisabeth Hosp, Breast Unit, Heidelberg, Germany
[4] Univ Coimbra, Dept Radiol, Coimbra, Portugal
[5] Heidelberg Univ Hosp, Dept Diagnost & Intervent Radiol, Heidelberg, Germany
[6] Sagara Hosp, Dept Radiol, Kagoshima, Japan
[7] Northeast Ohio Med Univ, Dept Radiol, Ravenna, OH USA
[8] Sankt Elisabeth Hosp, Breast Unit, Max Reger Str 5-7, D-69121 Heidelberg, Germany
关键词
B-mode ultrasound; shear wave elastography; breast cancer; reliability; VOLUME SCANNER ABVS; DIFFERENTIAL-DIAGNOSIS; ULTRASOUND; QUANTIFICATION; CLASSIFICATION; PERFORMANCE;
D O I
10.1002/jum.16344
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-Shear wave elastography (SWE) is increasingly used in breast cancer diagnostics. However, large, prospective, multicenter data evaluating the reliabil-ity of SWE is missing. We evaluated the intra-and interobserver reliability of SWE in patients with breast lesions categorized as BIRADS 3 or 4.Methods-We used data of 1288 women at 12 institutions in 7 countries with breast lesions categorized as BIRADS 3 to 4 who underwent conventional B-mode ultrasound and SWE. 1243 (96.5%) women had three repetitive con-ventional B-mode ultrasounds as well as SWE measurements performed by a board-certified senior physician. 375 of 1288 (29.1%) women received an addi-tional ultrasound examination with B-mode and SWE by a second physician. Intraclass correlation coefficients (ICC) were calculated to examine intra-and interobserver reliability.Results-ICC for intraobserver reliability showed an excellent correlation with ICC >0.9, while interobserver reliability was moderate with ICC of 0.7. There were no clinically significant differences in intraobserver reliability when SWE was performed in lesions categorized as BI-RADS 3 or 4 as well as in histopatho-logically benign or malignant lesions. Conclusion-Reliability of additional SWE was evaluated on a study cohort con-sisting of 1288 breast lesions categorized as BI-RADS 3 and 4. SWE shows an excellent intraobserver reliability and a moderate interobserver reliability in the evaluation of solid breast masses.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 50 条
  • [1] Intra- and Interobserver Variability of Shear Wave Elastography in Rectal Cancer
    Loft, Martina Kastrup
    Pedersen, Malene Roland Vils
    Grimm, Peter
    Lauritzen, Andreas Hoffmann
    Dam, Claus
    Rafaelsen, Soren Rafael
    CANCERS, 2022, 14 (11)
  • [2] Validation of intra- and interobserver reproducibility of shearwave elastography: Phantom study
    Mun, Han Song
    Choi, Seon Hyeong
    Kook, Shin Ho
    Choi, Yoonjung
    Jeong, Woo Kyoung
    Kim, Yongsoo
    ULTRASONICS, 2013, 53 (05) : 1039 - 1043
  • [3] Intra- and interobserver reliability of sensibility testing in asymptomatic individuals
    Rozental, TD
    Beredjiklian, PK
    Guyette, TM
    Weiland, AJ
    ANNALS OF PLASTIC SURGERY, 2000, 44 (06) : 605 - 609
  • [4] Intra- and interobserver reliability of ocular surface analyzer LacryDiag®
    Kos, Eva
    Cigic, Valentina
    Busic, Mladen
    Bjelos, Mirjana
    Miletic, Daliborka
    Elabjer, Biljana Juzmovic
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (08) : 1418 - 1422
  • [5] Intra- and interobserver reliability of umbilical vein blood flow
    Fernandez, Susana
    Figueras, Francesc
    Gomez, Olga
    Martinez, Josep Maria
    Eixarch, Elisenda
    Comas, Montserrat
    Puerto, Bienvenido
    Gratacos, Eduard
    PRENATAL DIAGNOSIS, 2008, 28 (11) : 999 - 1003
  • [6] Intra- and Interobserver Variability of US Elastography: How Does It Affect Quality?
    Lacout, Alexis
    Figl, Andrea
    Thariat, Juliette
    Marcy, Pierre-Yves
    RADIOLOGY, 2011, 260 (02) : 610 - 610
  • [7] Value of shear-wave elastography in the diagnosis of symptomatic invasive lobular breast cancer
    Sim, Y. T.
    Vinnicombe, S.
    Whelehan, P.
    Thomson, K.
    Evans, A.
    CLINICAL RADIOLOGY, 2015, 70 (06) : 604 - 609
  • [8] Efficacy of Ultrasound and Shear Wave Elastography for the Diagnosis of Breast Cancer-Related Lymphedema
    Polat, Ahmet Veysel
    Ozturk, Mesut
    Polat, Ayfer Kamali
    Karabacak, Ufuk
    Bekci, Tumay
    Murat, Naci
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (04) : 795 - 803
  • [9] The differential diagnosis of benign and malignant breast cancer using shear wave elastography (SWE)
    Wang, Baohua
    Cai, Zhenyu
    Hu, Ying
    Wang, Jing
    Chu, Yanhua
    Jiang, Tian'an
    Cheng, Jing
    Zheng, Shusen
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (17): : 7404 - 7411
  • [10] Intra- and Interobserver Reliability of Size Measurement of Morton Neuromas on Sonography
    Park, Young Hwan
    Choi, Won Seok
    Choi, Gi Won
    Kim, Hak Jun
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (09) : 2341 - 2345