Deep eutectic solvent- loaded Fe3O4@MIL-101(Cr) with core-shell structure for the magnetic solid phase extraction of non-steroidal anti-inflammatory drugs in environmental water samples

被引:17
|
作者
Yang, Li [1 ]
Wang, Shuang [1 ]
Xie, Zhongshui [1 ]
Xing, Rongrong [1 ]
Wang, Runqin [1 ]
Chen, Xuan [1 ]
Hu, Shuang [1 ]
机构
[1] Shanxi Med Univ, Sch Pharm, Taiyuan 030001, Peoples R China
基金
中国国家自然科学基金;
关键词
Non-steroidal anti-inflammatory drugs; Deep eutectic solvent; Magnetic solid phase extraction; Liquid phase microextraction; METAL-ORGANIC FRAMEWORK; ADSORBENT;
D O I
10.1016/j.microc.2022.108150
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel deep eutectic solvent -loaded magnetic solid phase extraction (DES-L-MSPE) method was proposed, which was based on the direct loading of a hydrophobic DES composed of L-menthol and lactic acid (1:2) into the pores of core-shell magnetic Fe3O4@MIL-101(Cr) nanoparticles. The function of DES was to condition the Fe3O4@MIL-101(Cr) and promote liquid phase microextraction for the analytes. Through coupling with HPLC-UV analysis, this method was utilized for the determination of six non-steroidal anti-inflammatory drugs (NSAIDs), including ketoprofen, naproxen, flurbiprofen, diclofenac sodium, ibuprofen, and mefenamic acid in environmental water samples. The influencing parameters such as type and ratio of DES, amount of adsorbent, sample solution pH, salt concentration, extraction time, elution solvent and time were investigated and opti-mized in detail. Under the optimal conditions, the method exhibited good linearity (5.0-1000 mu g/L for keto-profen, ibuprofen, 1.5-600 mu g/L for flurbiprofen, mefenamic acid, 2.5-1000 mu g/L for naproxen and 3.0-600 mu g/L for diclofenac sodium with the correlation coefficients ranging from 0.9972 to 0.9993), low limits of detection (0.20-1.1 mu g/L), and high precision (RSD < 8.2 %). Besides, the recoveries in spiked lake and river water samples were 89.8 %-110.4 % and 83.8 %-109.0 %, respectively. Taken together, the established method was proved to be simple, fast, highly sensitive and accurate for the determination of NSAIDs from aqueous matrices.
引用
收藏
页数:9
相关论文
共 40 条
  • [1] Magnetic nanoparticle of metal-organic framework with core-shell structure as an adsorbent for magnetic solid phase extraction of non-steroidal anti-inflammatory drugs
    Liu, Siyu
    Li, Shuo
    Yang, Wei
    Gu, Fan
    Xu, Haiyan
    Wang, Ting
    Sun, Duhong
    Hou, Xiaohong
    TALANTA, 2019, 194 : 514 - 521
  • [2] Magnetic solid phase extraction of non-steroidal anti-inflammatory drugs from water samples using a metal organic framework of type Fe3O4/MIL-101(Cr), and their quantitation by UPLC-MS/MS
    Wang, Ting
    Liu, Siyu
    Gao, Guihua
    Zhao, Pan
    Lu, Nan
    Lun, Xiaowen
    Hou, Xiaohong
    MICROCHIMICA ACTA, 2017, 184 (08) : 2981 - 2990
  • [3] Magnetic solid phase extraction of non-steroidal anti-inflammatory drugs from water samples using a metal organic framework of type Fe3O4/MIL-101(Cr), and their quantitation by UPLC-MS/MS
    Ting Wang
    Siyu Liu
    Guihua Gao
    Pan Zhao
    Nan Lu
    Xiaowen Lun
    Xiaohong Hou
    Microchimica Acta, 2017, 184 : 2981 - 2990
  • [4] PEG modified column MIL-101(Cr)/PVA cryogel as a sorbent in stir bar solid phase extraction for determination of non-steroidal anti-inflammatory drugs in water samples
    Wang, Yudan
    Jia, Mengtian
    Wu, Xia
    Wang, Ting
    Wang, Jian
    Hou, Xiaohong
    MICROCHEMICAL JOURNAL, 2019, 146 : 214 - 219
  • [5] Surface molecularly imprinted polymer based on core-shell Fe3O4@MIL-101(Cr) for selective extraction of phenytoin sodium in plasma
    Jia, Mengtian
    Zhu, Yanyan
    Guo, Dong
    Bi, Xiaogang
    Hou, Xiaohong
    ANALYTICA CHIMICA ACTA, 2020, 1128 : 211 - 220
  • [6] Magnetic solid-phase extraction of non-steroidal anti-inflammatory drugs from environmental water samples using polyamidoamine dendrimer functionalized with magnetite nanoparticles as a sorbent
    Alinezha, Heshmatollah
    Amiri, Amirhassan
    Tarahomi, Mehrasa
    Maleki, Behrooz
    TALANTA, 2018, 183 : 149 - 157
  • [7] Solid phase microextraction with poly(deep eutectic solvent) monolithic column online coupled to HPLC for determination of non-steroidal anti-inflammatory drugs
    Wang, Rong
    Li, Wenqing
    Chen, Zilin
    ANALYTICA CHIMICA ACTA, 2018, 1018 : 111 - 118
  • [8] Fabrication of calixarene-grafted bio-polymeric magnetic composites for magnetic solid phase extraction of non-steroidal anti-inflammatory drugs in water samples
    Yaacob, Syed Fariq Fathullah Syed
    Jamil, Arniza Khairani Mohd
    Kamboh, Muhammad Afzal
    Ibrahim, Wan Aini Wan
    Mohamad, Sharifah
    PEERJ, 2018, 6
  • [9] Novel nanofibers mat as an efficient, fast and reusable adsorbent for solid phase extraction of non-steroidal anti-inflammatory drugs in environmental water
    Jian, Ningge
    Qian, Liangliang
    Wang, Chunmin
    Li, Ruixian
    Xu, Qian
    Li, Jian
    JOURNAL OF HAZARDOUS MATERIALS, 2019, 363 : 81 - 89
  • [10] MIL-101(Fe)@TiO2 nanotube composite material is used for the solid phase extraction of non-steroidal anti-inflammatory drugs under the synergy of multiple interactions
    Liu, Hongmei
    Dang, Shihao
    Li, Mingdeng
    Ye, Baogui
    ANALYTICAL METHODS, 2022, 14 (08) : 798 - 805