Quasi-Alvarez drift-tube linac structures for heavy ion therapy accelerator facilities

被引:1
|
作者
Khalvati, Mohammad Reza [1 ,2 ]
Bencini, Vittorio [1 ]
Ramberger, Suitbert [1 ]
机构
[1] European Org Nucl Res, CERN, CH-1211 Geneva 23, Switzerland
[2] Inst Res Fundamental Sci IPM, Sch Particles & Accelerators, POB 19395-5531, Tehran, Iran
关键词
D O I
10.1103/PhysRevAccelBeams.26.022001
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
Next generation heavy ion therapy and research facilities require efficient accelerating structures. Particularly, at low beam energies, right after the standard scheme of the ion source, low-energy beam transfer, and radio-frequency quadrupole (RFQ), several options for accelerating structures are available including the classic drift-tube linac (DTL), the interdigital H-mode DTL (IH-DTL), and superconducting quarter-wave resonators. These structures need to integrate the beam acceleration with the focusing channel, nowadays typically provided by permanent-magnet quadrupoles (PMQs). The frequency of operation needs to be in line with that of the RFQ structure, and it has been chosen at 750 MHz for practical considerations for the Next Ion Medical Machine Study (NIMMS) that is the application focus of this manuscript. While classic DTL structures at low ion beam energies do not provide enough space for PMQs at that frequency within a single beta lambda period, IH-DTL structures do not provide the regular focusing channel with consequences on the beam quality. For these reasons, quasi-Alvarez drift-tube linac (QA-DTL) structures are reevaluated in this manuscript as they might fill this gap. They have not received much attention in the literature so far and therefore their design is described in detail. The design procedure presented here may serve as a blueprint for DTL design in general. In addition to the overall rf design, axial field stabilization with a new technique and multiphysics studies of the rf structure are described. A cost estimation completes the NIMMS QA-DTL study.
引用
收藏
页数:14
相关论文
共 4 条
  • [1] 11-20 MeV Alvarez Drift Tube Linac for low energy proton accelerator
    Teotia, Vikas
    Malhotra, Sanjay
    Kumar, Prashant
    Mishra, Elina
    Meshram, Sumit
    Chimurkar, Rajesh
    JOURNAL OF INSTRUMENTATION, 2023, 18 (06)
  • [2] Comparison of 352 MHz linac structures for injection into an ion therapy accelerator
    Nikitovic, L.
    Torims, T.
    Vretenar, M.
    IPAC23 PROCEEDINGS, 2024, 2687
  • [3] High power test of an injector linac for heavy ion cancer therapy facilities
    Lu, Liang
    Hattori, Toshiyuki
    Zhao, Huanyu
    Kawasaki, Katsunori
    Sun, Liangting
    He, Yuan
    Zhao, Hongwei
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2015, 18 (11):
  • [4] Investigation of beam stability in a high intensity drift tube linac for heavy ion inertial fusion
    Deitinghoff, H
    Parisi, G
    Sauer, A
    Bongardt, K
    Pabst, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 464 (1-3): : 539 - 545