Comparison of Lumbar Interbody Fusion with 3D-Printed Porous Titanium Cage Versus Polyetheretherketone Cage in Treating Lumbar Degenerative Disease: A Systematic Review and Meta-Analysis

被引:6
|
作者
Duan, Yuchen [1 ]
Feng, Dagang [1 ]
Li, Tong [1 ]
Wang, Yiran [2 ]
Jiang, Leiming [1 ]
Huang, Yong [1 ]
机构
[1] Hosp Chengdu Univ Tradit Chinese Med, Dept Orthoped, Chengdu, Peoples R China
[2] Chengdu Univ Tradit Chinese Med, Chengdu, Sichuan, Peoples R China
关键词
3D-printed porous titanium cage; Fusion rate; Meta-analysis; Polyetheretherketone cage; Subsidence rate; GRAFT SUBSIDENCE; PEEK; TANTALUM; ANTERIOR; OUTCOMES; LEVEL;
D O I
10.1016/j.wneu.2023.12.111
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
- OBJECTIVE: To compare the safety and radiological effectiveness of lumbar interbody fusion with a 3D -printed porous titanium (3D-PPT) cage versus a polyetheretherketone (PEEK) cage for the treatment of lumbar degenerative disease. - METHODS: This study was registered at PROSPERO (CRD42023461511). We systematically searched the PubMed, Embase, and Web of Science databases for related studies from inception to September 3, 2023. Review Manager 5.3 was used to conduct this meta -analysis. The reoperation rate, complication rate, fusion rate, and subsidence rate were assessed using relative risk and 95% confidence intervals. - RESULTS: Ten articles reporting 9 studies comparing lumbar interbody fusion with 3D-PPT cages versus PEEK cages for the treatment of lumbar degenerative disease were included. The subsidence rate at the 1 -year follow-up in the 3DPPT cage was significantly lower than that in the PEEK cage. The fusion rate in the 3D-PPT cage was significantly higher than that in the PEEK cage at the 6month follow-up. No significant difference was identified between the 2 groups at the 12 -month follow-up. No significant difference was identified between the 2 groups in terms of the complication rate and reoperation rate. There was a trend toward a lower complication rate and reoperation rate with the 3DPPT cage. - CONCLUSIONS: Compared with the PEEK cage, the 3D-PPT cage may be a safer implant. The 3D-PPT cage was associated with a higher fusion rate and lower subsidence rate. The 3D-PPT cage may accelerate the intervertebral fusion process, improve the quality of fusion and prevent the occurrence of subsidence.
引用
收藏
页码:144 / 156
页数:13
相关论文
共 50 条
  • [1] Clinical and radiological outcomes of titanium cage versus polyetheretherketone cage in lumbar interbody fusion: a systematic review and meta-analysis
    Wang, Haozhong
    Zhang, Hao
    Xiao, Changming
    Zhang, Kaiquan
    Qi, Lisheng
    NEUROSURGICAL REVIEW, 2025, 48 (01)
  • [2] 3D-printed porous titanium versus polyetheretherketone cages in lateral lumbar interbody fusion: a systematic review and meta-analysis of subsidence
    Liu, Shu-Xin
    Zeng, Teng-Hui
    Chen, Chien-Min
    He, Li-Ru
    Feng, An-Ping
    Jhang, Shang-Wun
    Lin, Guang-Xun
    FRONTIERS IN MEDICINE, 2024, 11
  • [3] Evaluation of cage subsidence in standalone lateral lumbar interbody fusion: novel 3D-printed titanium versus polyetheretherketone (PEEK) cage
    Dominik Adl Amini
    Ichiro Okano
    Lisa Oezel
    Jiaqi Zhu
    Erika Chiapparelli
    Jennifer Shue
    Andrew A. Sama
    Frank P. Cammisa
    Federico P. Girardi
    Alexander P. Hughes
    European Spine Journal, 2021, 30 : 2377 - 2384
  • [4] Evaluation of cage subsidence in standalone lateral lumbar interbody fusion: novel 3D-printed titanium versus polyetheretherketone (PEEK) cage
    Adl Amini, Dominik
    Okano, Ichiro
    Oezel, Lisa
    Zhu, Jiaqi
    Chiapparelli, Erika
    Shue, Jennifer
    Sama, Andrew A.
    Cammisa, Frank P.
    Girardi, Federico P.
    Hughes, Alexander P.
    EUROPEAN SPINE JOURNAL, 2021, 30 (08) : 2377 - 2384
  • [5] Vertebral Endplate Concavity in Lateral Lumbar Interbody Fusion: Tapered 3D-Printed Porous Titanium Cage versus Squared PEEK Cage
    Segi, Naoki
    Nakashima, Hiroaki
    Shinjo, Ryuichi
    Kagami, Yujiro
    Machino, Masaaki
    Ito, Sadayuki
    Ouchida, Jun
    Morishita, Kazuaki
    Oishi, Ryotaro
    Yamauchi, Ippei
    Imagama, Shiro
    MEDICINA-LITHUANIA, 2023, 59 (02):
  • [6] Comparison of Fusion, Subsidence, and Clinical Results Between 3D-Printed Porous Titanium Cage and Polyetheretherketone Cage in Posterior Lumbar Interbody Fusion: A Minimum of 2 Years Follow-Up
    Yang, Jae Jun
    Kim, Dong -Min
    Park, Sehan
    WORLD NEUROSURGERY, 2023, 177 : E732 - E741
  • [7] Application of 3D-printed porous titanium interbody fusion cage vs. polyether ether ketone interbody fusion cage in anterior cervical discectomy and fusion: A systematic review and meta-analysis update
    Zhai, Wan-Jing
    Liu, Lun
    Gao, Yu-Hao
    Qin, Shi-Lei
    Han, Peng-Fei
    Xu, Yun-Feng
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2024, 28 (01)
  • [8] Oblique lumbar interbody fusion versus minimally invasive transforaminal lumbar interbody fusion for the treatment of degenerative disease of the lumbar spine: a systematic review and meta-analysis
    Yun-lu Wang
    Xi-yong Li
    Lun Liu
    Song-feng Li
    Peng-fei Han
    Xiao-dong Li
    Neurosurgical Review, 46
  • [9] Oblique lumbar interbody fusion versus minimally invasive transforaminal lumbar interbody fusion for the treatment of degenerative disease of the lumbar spine: a systematic review and meta-analysis
    Wang, Yun-lu
    Li, Xi-yong
    Liu, Lun
    Li, Song-feng
    Han, Peng-fei
    Li, Xiao-dong
    NEUROSURGICAL REVIEW, 2023, 46 (01)
  • [10] Efficacy of oblique lumbar interbody fusion versus transforaminal lumbar interbody fusion in the treatment of lumbar degenerative diseases: a systematic review and meta-analysis
    Li, Xi-yong
    Wang, Yun-lu
    Yang, Su
    Liao, Chang-sheng
    Li, Song-feng
    Han, Peng-yong
    Han, Peng-fei
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (09) : 5657 - 5670