Imaging Real-Time Coronary Anatomy Using a Three-Dimensional Electrophysiology Mapping System

被引:0
|
作者
Javid, Rabeia [1 ,2 ]
Abdelrahman, Amr [2 ]
Thompson, Robert [3 ]
Puppala, Sapna [4 ]
Wheatcroft, Stephen B. [1 ,2 ]
Mozid, Abdul [2 ]
Tayebjee, Muzahir H. [1 ,2 ]
机构
[1] Univ Leeds, Sch Med, Leeds Inst Cardiovasc & Metab Med, Leeds, W Yorkshire, England
[2] Leeds Teaching Hosp NHS Trust, Dept Cardiol, Great George St, Leeds LS1 3EX, W Yorkshire, England
[3] Leeds Teaching Hosp NHS Trust, Mech Engn Radiotherapy Technol Serv, Leeds, W Yorkshire, England
[4] Leeds Teaching Hosp NHS Trust, Dept Cardio Vasc Radiol, Leeds, W Yorkshire, England
关键词
Electroanatomical mapping systems; Three-dimensional mapping systems; 3D navigation system; Percutaneous coronary intervention; PCI; ABLATION;
D O I
10.1007/s12265-022-10341-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study is to evaluate the feasibility of creating fast three-dimensional maps of coronary arteries and to develop a bipolar coronary guidewire in vitro and determine whether it can be localised accurately within the model. A total of five patients were recruited, and EnSite Precision was utilised to create 3D coronary anatomy. A water bath to accommodate a 3D-printed coronary model was developed to test the performance of the bipolar angioplasty wire. Successful guidewire localisation and 3D reconstruction of coronary anatomy were achieved in all the cases. No complications. The bipolar wire was able to collect point clouds, and localisation of the distal tip was excellent when tested in the water bath. Our study demonstrates the feasibility and safety of utilising EAMS to collect coronary anatomy. Real-time tracking with a bipolar catheter is accurate when tested in vitro.
引用
收藏
页码:715 / 721
页数:7
相关论文
共 50 条
  • [1] Imaging Real-Time Coronary Anatomy Using a Three-Dimensional Electrophysiology Mapping System
    Rabeia Javid
    Amr Abdelrahman
    Robert Thompson
    Sapna Puppala
    Stephen B. Wheatcroft
    Abdul Mozid
    Muzahir H. Tayebjee
    Journal of Cardiovascular Translational Research, 2023, 16 : 715 - 721
  • [2] Real-time three-dimensional optoacoustic imaging using an acoustic lens system
    Niederhauser, JJ
    Jaeger, M
    Frenz, M
    APPLIED PHYSICS LETTERS, 2004, 85 (05) : 846 - 848
  • [3] Stress echocardiography using real-time three-dimensional imaging
    Berbarie, Rafic F.
    Dib, Elie
    Ahmad, Masood
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2018, 35 (08): : 1196 - 1203
  • [4] Three-dimensional reconstruction of coronary arteriole plexus imaging using real-time contrast echocardiography
    Toshida, T
    Kutsuyama, T
    Okazaki, J
    Hirayama, H
    Ohtani, K
    Kashiwagi, Y
    Yagura, S
    Iwata, A
    Asanuma, T
    Ishikura, F
    Beppu, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 344A - 345A
  • [5] Real-time three-dimensional electrical impedance imaging
    Blue, RS
    Isaacson, D
    Newell, JC
    PHYSIOLOGICAL MEASUREMENT, 2000, 21 (01) : 15 - 26
  • [6] Real-time three-dimensional imaging of macroscopic structures
    Wilson, T
    Neil, MAA
    Juskaitis, R
    JOURNAL OF MICROSCOPY-OXFORD, 1998, 191 : 116 - 118
  • [7] Photoacoustic tomography system for noninvasive real-time three-dimensional imaging of epilepsy
    Wang, Bo
    Xiang, Liangzhong
    Jiang, Max S.
    Yang, Jianjun
    Zhang, Qizhi
    Carney, Paul R.
    Jiang, Huabei
    BIOMEDICAL OPTICS EXPRESS, 2012, 3 (06): : 1427 - 1432
  • [8] Real-Time Three-Dimensional Pedestrian Localization System Using Smartphones
    Shin, Beomju
    Kim, Taehun
    Lee, Taikjin
    SENSORS, 2024, 24 (02)
  • [9] Radiofrequency ablation of cardiac arrhythmias using a three-dimensional real-time position management and mapping system
    Schreieck, J
    Ndrepepa, G
    Zrenner, B
    Schneider, MAE
    Weyerbrock, S
    Dong, J
    Schmitt, C
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (12): : 1699 - 1707
  • [10] Real-time three-dimensional infrared imaging using fringe projection profilometry
    Zuo, Chao
    Chen, Qian
    Feng, Shijie
    Gu, Guohua
    Asundi, Anand
    Chinese Optics Letters, 2013, 11 (SUPPL.2)