Impedance of in-air undulator vacuum chamber in HEPS

被引:0
|
作者
Li, Jintao [1 ,2 ]
Wang, Na [1 ]
Yue, Sen [1 ,2 ]
Tian, Saike [1 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, 19B Yuquan Rd, Beijing, Peoples R China
[2] Univ Chinese Acad Sci, 1 Yanqihu East Rd, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Acceleration cavities and superconducting magnets (high-temperature superconductor; radiation hardened magnets; normal-conducting; permanent magnet devices; wigglers and undula-tors); Instrumentation for particle accelerators and storage rings-high energy (linear accelerators; synchrotrons); Coherent instabilities;
D O I
10.1088/1748-0221/18/12/P12003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Undulators with small gap have been widely used in various light sources all over the world for the demand of high brilliance. A large number of in-air undulators with small gap will be installed in the storage ring of the High Energy Photon Source, and become one of the important impedance contributors. Antechambers are adopted for the bypass of the synchrotron radiations, as well as to reach high vacuum in the beam pipe with small aperture. Due to the asymmetric structure of the vacuum chamber, monopole wakefield in the transverse planes will be excited by the beam passage. In addition, photon absorbers will be installed in the vacuum chamber of the in-air undulators to shield the downstream components, which will introduce extra resonances in the transverse planes. In this paper, a series of numerical simulations are performed to investigate the impedance of the in-air undulator vacuum chamber. The high order modes generated by the photon absorber and their mitigations are also investigated.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Design and development of vacuum chamber for superconducting undulator at IHEP
    Chen, Zilin
    Zhang, Xiangzhen
    Yang, Xiangchen
    Wei, Junhao
    Geng, Jieru
    Bian, Xiaojuan
    Zhang, Lei
    Li, Yuhui
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1056
  • [2] Impedance evaluation of in-vacuum undulator at KEK Photon Factory
    Tanaka, O. A.
    Nakamura, N.
    Obina, T.
    Tsuchiya, K.
    Takai, R.
    Sakanaka, S.
    Yamamoto, N.
    Kato, R.
    Adachi, M.
    9TH INTERNATIONAL PARTICLE ACCELERATOR CONFERENCE (IPAC18), 2018, 1067
  • [3] Aluminum coating in the undulator vacuum chamber for the linac coherence light source
    Walters, Dean
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 1007 - 1009
  • [4] Coupling impedance of an in-vacuum undulator: Measurement, simulation, and analytical estimation
    Smaluk, Victor
    Fielder, Richard
    Blednykh, Alexei
    Rehm, Guenther
    Bartolini, Riccardo
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2014, 17 (07):
  • [5] Analytical presentation of resistive impedance for the laminated vacuum chamber
    Ivanyan, M
    Tsakanian, A
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2006, 9 (03):
  • [6] Longitudinal coupling impedance of an abrupt junction in a vacuum chamber
    Davino, D
    Dôme, G
    Miano, G
    Panariello, G
    Vaccaro, VG
    Verolino, L
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A-NUCLEI PARTICLES AND FIELDS, 1999, 112 (12): : 1401 - 1430
  • [7] Impedance analysis of the PEP-II vacuum chamber
    Ng, CK
    Weiland, T
    PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 3061 - 3063
  • [8] Comparison QA methods of brachytherapy using well ionization chamber and in-air method
    Azmi, Nor Faranaz Shamin Nor
    Zakaria, Ahmad
    Abdullah, Reduan
    Hadi, Norha Abdul
    MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES, 2012, 8 (04): : 220 - 226
  • [9] Influence of ion chamber response on in-air profile measurements in megavoltage photon beams
    Tonkopi, E
    McEwen, M
    Kawrakow, I
    MEDICAL PHYSICS, 2005, 32 (06) : 2071 - 2071
  • [10] Influence of ion chamber response on in-air profile measurements in megavoltage photon beams
    Tonkopi, E
    McEwen, MR
    Walters, BRB
    Kawrakow, I
    MEDICAL PHYSICS, 2005, 32 (09) : 2918 - 2927